• Title/Summary/Keyword: Response Rate

Search Result 5,548, Processing Time 0.031 seconds

Optimal design of seismic reinforcement for structures with asymmetric rigidity plans using genetic algorithm (유전자 알고리즘을 이용한 비대칭 강성 구조물의 내진보강 최적설계)

  • Lee, Joon-Ho;Kim, Yu-Seong;Sung, Eun-Hee
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.2
    • /
    • pp.65-73
    • /
    • 2024
  • In this study, we propose an optimal design method by applying the Prefabricated Buckling Restrained Brace (PF-BRB) to structures with asymmetrically rigidity plan. As a result of the PF-BRB optimal design of a structure with an asymmetrically rigidity plan, it can be seen that the reduction effect of dynamic response is greater in the case of arrangement considering the asymmetric distribution of stiffness (Asym) than in the case of arrangement in the form of a symmetric distribution (Sym), especially It was confirmed that at an eccentricity rate of 20%, the total amount of reinforced PF-BRBs was also small. As a result of analyzing the dynamic response characteristics according to the change in eccentricity of the asymmetrically rigidity plan, the distribution of the reinforced PF-BRB showed that the larger the eccentricity, the greater the amount of damper distribution around the eccentric position. Additionally, when comparing the analysis models with an eccentricity rate of 20% and an eccentricity rate of 12%, the response reduction ratio of the 20% eccentricity rate was found to be large.

A study on non-response bias adjusted estimation in business survey (사업체조사에서의 무응답 편향보정 추정에 관한 연구)

  • Chung, Hee Young;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.1
    • /
    • pp.11-23
    • /
    • 2020
  • Sampling design should provide statistics to meet a given accuracy while saving cost and time. However, a large number of non-responses are occurring due to the deterioration of survey circumstances, which significantly reduces the accuracy of the survey results. Non-responses occur for a variety of reasons. Chung and Shin (2017, 2019) and Min and Shin (2018) found that the accuracy of estimation is improved by removing the bias caused by non-response when the response rate is an exponential or linear function of variable of interests. For that case they assumed that the error of the super population model follows normal distribution. In this study, we proposed a non-response bias adjusted estimator in the case where the error of a super population model follows the gamma distribution or the log-normal distribution in a business survey. We confirmed the superiority of the proposed estimator through simulation studies.

Viscoplastic analysis of thin-walled tubes under cyclic bending

  • Pan, Wen-Fung;Hsu, Chien-Min
    • Structural Engineering and Mechanics
    • /
    • v.7 no.5
    • /
    • pp.457-471
    • /
    • 1999
  • In this paper, different curvature-rates are controlled to highlight the characteristic of viscoplastic response in cyclic bending tests. The curvature-ovalization apparatus, which was designed by Pan et al. (1998), is used for conducting the curvature-controlled experiments on thin-walled tubular specimens for AISI 304 stainless steel under cyclic bending. The results reveals that the faster the curvature-rate implies, the fast degree of hardening of the metal tube. However, the ovalization of the tube cross-section increases when the curvature-rate increases.

Novel LUT Measurement Method for Response Time Compensation

  • Kim, Tae-Sung;Park, Bong-Im
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.331-334
    • /
    • 2004
  • A new measurement scheme is proposed to generate an optimized boost table for video rate LCD response time compensation. This method, which closely follows basic theory, enables up to a 90% reduction in the lookup table creation time compared to conventional methods. Furthermore, while conventional approaches require all measurements to be repeated in order to load the entire LUT whenever key parameters such as refresh rate or boost intensity are modified, the method proposed in this paper allows the new table to be calculated by utilizing saved waveform data without the need for any repeated measurements.

  • PDF

Feed Rate Control for the Head-Feed Thresher (수급식탈곡기(穗給式脱穀機)의 공급율(供給率) 제어(制御)(II) -제어시스템 설계 및 시뮬레이션-)

  • Choi, Y.S.;Chung, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.110-122
    • /
    • 1990
  • This study was undertaken to develop the feed rate control system for the head feed thresher by making use of the microprocessor and to evaluate the response of the system to a various threshing conditions. The control unit was composed of one-board microcomputer. The speed of the wet-paddy feeding chain was controlled by dc moter with PI controller. It was used the adaptive control method to maintain the constant feed rate regardless of the fed rice varieties. The sliding type potentiometer was used as the feed rate sensor, which was attached on the sheaf-holding apparatus. The mathematical models of the system components were derived and computer simulation was developed for investigating the parameters affecting on control performance and for estimating the response of the system. A one-board microcomputer-based feed rate control system developed in this study was properly functioned and assessed as adequate for the feed rate control system of the head feed thresher. Based on the simulation for the bundle feed, it was anticipated that the lower setting value of the cylinder speed(RL) is to be set higher than the limiting operational speed. In addition, the higher setting value of the cylinder speed(RH) is to be set lower than the limiting cylinder speed for threshing. The computer simulation for the continuous spread feed showed that the lower the setting value of straw layer thickness(LL) was set, the shorter the correction time. However, if too low LL may be established, the feed rate could not reach to its desired rate.

  • PDF

Analysis of the Asymmetric Interest rate Adjustments in Banks and Non-Bank Depository Institutions (은행 및 비은행 예금취급기관의 비대칭적 금리조정 분석)

  • Eui-hwan Park
    • Asia-Pacific Journal of Business
    • /
    • v.15 no.2
    • /
    • pp.223-236
    • /
    • 2024
  • Purpose - The purpose of the paper is to empirically investigate the asymmetric adjustment of loan and deposit interest rates among banks and non-bank depository institutions. Design/methodology/approach - We construct a VAR model using time series data comprising loan and deposit interest rates of banks and non-bank depository institutions, along with the call rate. Based on this model, we conduct impulse-response analysis and variance decomposition to investigate the dynamic relationship between the interest rates. Findings - In the case of banks and credit unions, the responses of deposit rates to the call rate are larger than the responses of loan rates, and we cannot find evidence of non-linear responses. In the case of savings banks, the responses of loan rates to the call rate are larger than the responses of deposit rates. The responses of loan rates to a positive call rate shock are statistically significant, while the responses of loan rates to a negative call rate shock are not statistically significant. Research implications or Originality - This study differs from previous research in that it examines the asymmetric response of loan and deposit rates of both banks and non-bank financial institutions to changes in the call rate. The implications for the impact of these findings on the financial system and income inequality are presented.

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.

Effect of Temperature-increase Rate and Terminal Temperature on the Solubilization of Sewage Sludge using Microwave Irradiation

  • Park, Woon-Ji;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.48-52
    • /
    • 2009
  • Solubilization of sewage sludge creates favorable conditions for anaerobic microorganisms to produce biogas. In this paper, we quantify the effect of heating pretreatment on the degree of solubilization of sewage sludge. The pretreatment process was carried out using a lab-scale industrial microwave unit (2450 MHz frequency). Response surface analysis was applied to determine the combination of temperature-increase rate (ramp rate) (2.9 to 17.1 ${^{\circ}C}$/min) and terminal temperature (52 to 108${^{\circ}C}$). Both ramp rate and temperature significantly affected the solubilization degree of sludge. Within the design boundaries, the conditions predicted to maximize the solubilization degree of 15.8% were determined to be 2.9 ${^{\circ}C}$/min and 104${^{\circ}C}$.

Analysis of Laser Diode Equivalent Circuit using Rate Equation (Rate equation을 이용한 광송신용 LD의 등가회로 분석)

  • Kim Do-Kyoon;Yun Young-Sul;Lee Jun-Jea;Choi Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.46-49
    • /
    • 2004
  • 레이저 다이오드 (LD)의 광 직접 변조시 광자와 전자의 동역학에 의하여 입출력 관계가 결정된다. 이는 LD의 직접 변조 시 대역폭을 제한하는 요소로 작용한다. 높은 대역폭을 가지는 광송신기 설계를 위하여 LD의 등가회로 분석은 필수적이다. LD의 등가회로는 E/O response를 이용하여 소신호 분석을 통해 얻을 수 있으며, E/O response는 rate equation을 이용하여, 구할 수 있다. LD의 등가회로는 직렬 저항값, 기생 커패시턴스, 외부 회로와의 연결을 위한 와이어에 기인하는 인덕턴스 성분 등으로 구성된다. 본 논문에서는, rate equation을 사용하여 계산된 결과를 이용하여, LD의 등가회로를 도출하였다.

  • PDF