• Title/Summary/Keyword: Response Rate

Search Result 5,493, Processing Time 0.029 seconds

Viscoplastic analysis of thin-walled tubes under cyclic bending

  • Pan, Wen-Fung;Hsu, Chien-Min
    • Structural Engineering and Mechanics
    • /
    • v.7 no.5
    • /
    • pp.457-471
    • /
    • 1999
  • In this paper, different curvature-rates are controlled to highlight the characteristic of viscoplastic response in cyclic bending tests. The curvature-ovalization apparatus, which was designed by Pan et al. (1998), is used for conducting the curvature-controlled experiments on thin-walled tubular specimens for AISI 304 stainless steel under cyclic bending. The results reveals that the faster the curvature-rate implies, the fast degree of hardening of the metal tube. However, the ovalization of the tube cross-section increases when the curvature-rate increases.

Novel LUT Measurement Method for Response Time Compensation

  • Kim, Tae-Sung;Park, Bong-Im
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.331-334
    • /
    • 2004
  • A new measurement scheme is proposed to generate an optimized boost table for video rate LCD response time compensation. This method, which closely follows basic theory, enables up to a 90% reduction in the lookup table creation time compared to conventional methods. Furthermore, while conventional approaches require all measurements to be repeated in order to load the entire LUT whenever key parameters such as refresh rate or boost intensity are modified, the method proposed in this paper allows the new table to be calculated by utilizing saved waveform data without the need for any repeated measurements.

  • PDF

Feed Rate Control for the Head-Feed Thresher (수급식탈곡기(穗給式脱穀機)의 공급율(供給率) 제어(制御)(II) -제어시스템 설계 및 시뮬레이션-)

  • Choi, Y.S.;Chung, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.110-122
    • /
    • 1990
  • This study was undertaken to develop the feed rate control system for the head feed thresher by making use of the microprocessor and to evaluate the response of the system to a various threshing conditions. The control unit was composed of one-board microcomputer. The speed of the wet-paddy feeding chain was controlled by dc moter with PI controller. It was used the adaptive control method to maintain the constant feed rate regardless of the fed rice varieties. The sliding type potentiometer was used as the feed rate sensor, which was attached on the sheaf-holding apparatus. The mathematical models of the system components were derived and computer simulation was developed for investigating the parameters affecting on control performance and for estimating the response of the system. A one-board microcomputer-based feed rate control system developed in this study was properly functioned and assessed as adequate for the feed rate control system of the head feed thresher. Based on the simulation for the bundle feed, it was anticipated that the lower setting value of the cylinder speed(RL) is to be set higher than the limiting operational speed. In addition, the higher setting value of the cylinder speed(RH) is to be set lower than the limiting cylinder speed for threshing. The computer simulation for the continuous spread feed showed that the lower the setting value of straw layer thickness(LL) was set, the shorter the correction time. However, if too low LL may be established, the feed rate could not reach to its desired rate.

  • PDF

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.

Effect of Temperature-increase Rate and Terminal Temperature on the Solubilization of Sewage Sludge using Microwave Irradiation

  • Park, Woon-Ji;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.48-52
    • /
    • 2009
  • Solubilization of sewage sludge creates favorable conditions for anaerobic microorganisms to produce biogas. In this paper, we quantify the effect of heating pretreatment on the degree of solubilization of sewage sludge. The pretreatment process was carried out using a lab-scale industrial microwave unit (2450 MHz frequency). Response surface analysis was applied to determine the combination of temperature-increase rate (ramp rate) (2.9 to 17.1 ${^{\circ}C}$/min) and terminal temperature (52 to 108${^{\circ}C}$). Both ramp rate and temperature significantly affected the solubilization degree of sludge. Within the design boundaries, the conditions predicted to maximize the solubilization degree of 15.8% were determined to be 2.9 ${^{\circ}C}$/min and 104${^{\circ}C}$.

Analysis of Laser Diode Equivalent Circuit using Rate Equation (Rate equation을 이용한 광송신용 LD의 등가회로 분석)

  • Kim Do-Kyoon;Yun Young-Sul;Lee Jun-Jea;Choi Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.46-49
    • /
    • 2004
  • 레이저 다이오드 (LD)의 광 직접 변조시 광자와 전자의 동역학에 의하여 입출력 관계가 결정된다. 이는 LD의 직접 변조 시 대역폭을 제한하는 요소로 작용한다. 높은 대역폭을 가지는 광송신기 설계를 위하여 LD의 등가회로 분석은 필수적이다. LD의 등가회로는 E/O response를 이용하여 소신호 분석을 통해 얻을 수 있으며, E/O response는 rate equation을 이용하여, 구할 수 있다. LD의 등가회로는 직렬 저항값, 기생 커패시턴스, 외부 회로와의 연결을 위한 와이어에 기인하는 인덕턴스 성분 등으로 구성된다. 본 논문에서는, rate equation을 사용하여 계산된 결과를 이용하여, LD의 등가회로를 도출하였다.

  • PDF

Bit Error Characteristics of Passive Phase Conjugation Underwater Acoustic Communication Due to a Drifting Source

  • Lin Chun-Dan;Ro Yong Ju;Rouseff Daniel;Yoon Jong Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2E
    • /
    • pp.61-66
    • /
    • 2005
  • Experimental work in underwater acoustic communications using passive phase conjugation has shown that the demodulation error depends on the relative drift rate between the source and receiver [Rouseff et al., IEEE J. Oceanic Eng. 26, 821-831 (2001)]. The observed effect involves the mismatch between the initial impulse response and the subsequent response after the source or receiver has changed locations. In the present work, the effect of drifting source is analyzed by numerical simulations and compared to the experimental results. The communications bit error rate is qualified as a function of drift rate, drifting direction, and source-receiver range.

A performance improvement method in the gun fire control system compensating for measurement bias error of the target tracking sensor (표적추적센서의 측정 바이어스 오차 보상에 의한 사격통제장치 성능 향상 기법)

  • Kim, Jae-Hun;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.121-130
    • /
    • 2000
  • A practical method is proposed to improve hit probability of the digital gun fire control system, when the measured rate of the tracking sensor becomes biased under some operational situation. For ground moving target it is shown that the well-known Kalman filter which uses position measurement only can be optimally used to eliminate the rate bias error. On the other hand, for 3D moving aircraft we present a new algorithm which incorporate FIR-type filter, which uses position and rate measurement at the same time, and the fixed-lag smoother using position measurement only, and show that it has the optimal performance in terms of both estimation accuracy and response time.

  • PDF

Very Efficient 6-ary Runlength-Limited Code Approaching Shannon Capacity for Optical Storage Channels (Shannon Capacity에 근접하는 고효율의 6-ary Runlength-Limited Code)

  • Jhee, Yoon-Kyoo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.29-35
    • /
    • 2008
  • Very efficient 6-ary runlength-limited codes for a six-level optical recording channel are presented when d = 3. The 6-ary(3, 15) code of rate 6/7 is given achieving coding efficiency of 98.87%. The efficiency of rate 13/15, (3, 20) code is 99.95%, which approaches the Shannon capacity. To increase the accurary of reading 6-ary signal, partial response modes are also investigated.