• Title/Summary/Keyword: Response Change

Search Result 3,936, Processing Time 0.03 seconds

The Effect of Different Light Quality on the Change of Membrane PD of the Guard Cell in Tradescantia virginiana L.

  • Lee, Joon-Sang
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.89-92
    • /
    • 2004
  • The effects of different light quality on the change of membrane potential difference (PD) of the guard cell in the intact leaf have been investigated. The mombrane PD was about -5.5 mV by white light of 600 $\mu$moles $m^{-2}\; s^{-1}$. The mean PD of change caused by red light was about -5.2 mV at the light intensity of 80 $\mu$moles $m^{-2}\; s^{-1}$. Membrane PD of guard cells in response to blue light was saturated at low light intensity. However, red and green light enhanced the change of membrane PD of guard cells with increasing intensity. In green light the biggest change of memrane PD was around -4 mV, whereas, with blue light the change of of memrane PD was around -2 mV. Accordingly, the membrane PD of guard cell showed the different degree of hyper-polarization by each wavelength.

The Effect of Electrical Stimulation Applied in Dominant Forearm on Autonomic Nervous System Response of Both Hands (우세측 전완에 적용한 전기자극이 양쪽 손 자율신경계 반응에 미치는 효과)

  • Lee, Dong-Geol;Seo, Sam-Ki;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the effect of electrical stimulation applied in dominant forearm on autonomic nervous system response of both hands. Methods : Fourteen healthy subjects (women) received low frequency-high intensity electrical stimulation to one forearm. The subjects assigned to two groups; a ipsilateral stimulation group (n=7) and a contralateral stimulation group (n=7). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was set as 15 minutes. Measuring items were the skin conduction velocity, the blood flow, and the pulse rate, which were measured total 3 times (pre, post, and post 10 min.). Results : The skin conduction velocity showed a significant difference according to the change of the time in both hands, but there was no significant difference according to time in the blood flow, and the change of the pulse frequency regardless of stimulus side. Conclusion : These results demonstrate that the low frequency-high intensity electrical stimulation applied dominant forearm can increase selectively only with the skin conduction velocity, which may be helpful for the activation of the sudomotor function of both hands by the activation of sympathetic nerve.

Change of Fractional Anisotropy in the Left Inferior Frontal Area after Motor Learning (운동학습에 의한 왼쪽 하전두영역의 분할비등방성의 변화)

  • Park, Ji-Won;Nam, Ki-Seok
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.109-115
    • /
    • 2010
  • Purpose: This study was to delineate the structural change of neural pathway after sequential motor learning using diffusion tensor imaging (DTI). Methods: The participants were 16 healthy subjects, which were divided by training (n=8) and control (n=8) group. The task for the training was the Serial Reaction Time Task (SRTT) which was designed by Superlab program. When the 'asterisk' shows up in the 4 partition spaces on the monitor, the subject presses the correct response button as soon as possible. The training group participated in the training program of motor learning with SRTT composed of 24 digits pattern in one hour per daily through 10 days during 2 weeks. Results: In the behavioral results the training group showed significant changes in the increase of response number and the reduction of response time than those of the control group. There was significant difference in the left inferior frontal area in the fractional anisotropy (FA) map of the training group in DTI analysis. Conclusion: Motor sequential learning as like SRTT may be needed to the learning of language and visuospatial processing and may be induced for the experience-dependent structural plasticity during short period.

A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 2. Driver's Perception Property (전조등 조도변동에 대한 운전자의 인식연구 : 2. 운전자의 시인 특성)

  • Kim, Gi-Hoon;Lee, Chang-Mo;Jung, Seun-Gun;Jo, Duk-Su;Suk, Dae-Ill;Jo, Mun-Seong;Kim, Hyng-Keon;Kim, Huyn-Ji;An, Ok-Hee;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.1-12
    • /
    • 2007
  • Through this experiment driver's perception were measured. An analysis of the perception measurement result analyzed the subject's obstacle perception response time according to voltage patterns. The difference in the reaction time between men and women was also analyzed. Futhermore, the obstacle perception response time was analyzed according to the rate of the brightness of the headlamp. The relative delay time was analyzed In reference to times when there was no voltage change.

The Electrophysiology Application on Guard Cells to See the Influence of Carbon Dioxide

  • Lee, Joon-Sang
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.763-770
    • /
    • 2014
  • The effect of $CO_2$ on the opening of stomata in the intact leaf of Commelina communis has been investigated. Full opening of stomatal apertures(around $18{\mu}m$) was achieved in the intact leaf by addition of $CO_2$($900{\mu}mol\;mol^{-1}$). At 90 minutes, the stomatal apertures of leaves treated with $CO_2$ free air were reduced. In contrast, stomata opened most widely with the treatment of $CO_2$ air at 90 minutes. The effects of light, $CO_2$ air and $CO_2$ free air on the change of membrane potential difference(PD) were measured. Fast hyperpolarization of guard cell membrane PD was recorded reaching up to -12 mV in response to light. If $CO_2$ free air was given firstly, there was no response. When light was given after $CO_2$ free air, the light effect was very clear. At the onset of $CO_2$ air, the PD showed a dramatic hyperpolarization to about -25 mV. Changes in the pH of apoplast in intact leaves in response to $CO_2$ air were observed. $CO_2$ air caused a change of 0.4 pH unit. Therefore, it can be hypothesized that $CO_2$ flowing could stimulate proton efflux which is a necessary precursor of stomatal opening.

The Characteristics of Transient Response vs. Lasing Wavelengths and Directions in Gain-Clamped L-band EDFA (고정이득 L-band EDFA에서 발진 파장 및 방향에 따른 과도응답 특성)

  • Kim Ik sang;Kim Chang bong;Yang Heng;Sohn Young ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3A
    • /
    • pp.160-167
    • /
    • 2005
  • The gain-clamped EDFA has been developed to eliminate the output power change of WDM surviving channels to occur with added or dropped channels, which degrades the performance of WDM optical network. It maintains the constant gain of surviving channels when WDM channels are added or dropped in a network amplifying node. In this paper, the hi-directionally pumped gain-clamped EDFA is implemented to compensate the change of the input power by a lasing. The results show that the lasing of a short wavelength and backward propagation is the optimal condition to minimize the transient response of surviving channels in terms of the overshoot and gain saturation due to the inhomogeneous broadening effect.

A Study on the Light Weighting of APU through Structural Analysis (구조해석을 통한 보조발전기 경량화에 관한 연구)

  • Kim, Hye-Eun;Kim, Jin-Hoon;Noh, Sang-Wan;Kim, Byeong-Ho;Baek, Hyun-Moo
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.4
    • /
    • pp.895-910
    • /
    • 2019
  • Purpose: The purpose of this study is to lighten the APU (Auxiliary Power Unit) structure of the KAAV (Korea Assault Amphibious Vehicle) through structural analysis. Methods: Commercially-available program (MIDAS.NFX) was used for finite element analysis. Frequency response analysis was performed through linear static and mode analyses to verify the structural stability according to the change of the structural materials. Results: Numerical simulation (linear static, mode and frequency response analyses) results showed that the safety factor of the APU was over 1.5 even under the worst case conditions. The APU made by aluminum structures was expected to be available in the military field, since every requirements in the KDS (Korean Defense Specifications) was fulfilled during the various tests and evaluations. Conclusion: The structural analysis was verified that the structural stability of the APU structure of the KAAV after change of the structural material.

Development of a Draft Control System for Tractor Using a Proportional Valve (비례밸브를 이용한 트랙터 견인력제어시스템 개발)

  • Lee, S.S.;Lee, J.Y.;Mun, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.9-15
    • /
    • 2006
  • Draft control is key technique in plow control system for automation of implement control system. To make the consistent draft force is an essential factor for preventing the reduction of working efficiency by tractor's slip and also improving the working efficiency. Therefore, the purpose of this study is to develop the draft sensor for draft control of plow and evaluate the usability of the algorithm of draft control system using proportional control valve. The developed draft control system could extract the draft force very well regardless of draft condition, change of setting draft force and response time in the response characteristic test. The maximum draft force at 3-Point linkage was 10,000 N and the deviation of the control system was 125.8 N in steady state condition. The developed control system worked very well with regard to the change of draft force in field and even in soil condition with soil reaction. The results of experiment showed the characteristics of response was sufficient to be used as the implement draft control system for tractor using proportional valve.

The Blood Pressure Response during Graded Exercise Test in Obese Adults

  • Shin, Kyung-A
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.215-222
    • /
    • 2017
  • Obesity has been directly associated with the development of hypertension and cardiovascular disease. The purpose of this study was to investigate the blood pressure response during graded exercise test in obese adults. 189 subjects (age: $47.96{\pm}10.23$) were assigned to two groups: non-obese group (N=105, BMI: $22.05{\pm}1.57$, waist circumference: $76.90{\pm}6.17$) and obese group (N=84, BMI: $26.96{\pm}2.51$, waist circumference: $88.29{\pm}6.41$). The subjects underwent health screening and exercise treadmill test from January 2012 to December 2014. Graded exercise test was performed according to the Bruce protocol. Exercise duration (P=0.046) and METs (P=0.015) were significantly lower in obese group than non-obese group. There was no difference in the rate of change in blood pressure response between obese group and non-obese group during exercise, and the recovery rate of systolic blood pressure was delayed in the obese group compared to non-obese group in the first recovery period (P=0.020). The significant factors of increasing rate of change in maximum systolic blood pressure was waist (P=0.046) and hip circumference (P=0.008). In conclusion, these results demonstrate that, for hypertension prevention in obese adults, waist and hip circumference levels should be managed within normal range.