• Title/Summary/Keyword: Respiratory training

Search Result 219, Processing Time 0.036 seconds

The Changes in the Ultrasound Imaging of Abdominal Muscles based on the Inspiratory Muscle Strengthening Training of Low Back Pain Patients (들숨군 강화 훈련이 허리통증환자의 배근육 초음파 영상 구조 변화에 미치는 영향)

  • Ko, Jeongah;Park, Woongsik;Moon, Seyoung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.3
    • /
    • pp.29-37
    • /
    • 2017
  • Purpose: The purpose of this study was to classify patients with chronic back pain according to the degree of their back pain, and to compare the pain dysfunction index with the qualitative changes in abdominal muscles. Therefore, we aimed to provide a basis for the treatment intervention method for patients with back pain. Methods: Twenty patients with chronic back pain were purposive sample to a group of 10 patients with a back pain index of 60 % or more and a group with less than 60 % of back pain, and the subjects who voluntarily participated in the study After receiving the letter, I conducted the research the dysfunction of back pain was measured by the Korean version of the Oswestry Disability Index (KODI), and the ultrasonic wave (Ultrasound MyLabOne, ESAOTE, Italy) And the white area index, and the abdominal muscle movement was used as the exercise instrument POWER breathe K5 (Hab direct, UK), which strengthens the respiratory muscles through threshold-muscle traction. Result: In this study, patients with chronic back pain were subjected to breathing exercises, which led to the decrease in back pain dysfunction. The ultrasonographic analysis of abdominal muscles revealed that both the white area index and muscle image density in the skeletal muscle and in the outer muscle of the abdomen gradually decreased over time. Conclusion: It is thought that introducing back pain patients to abdominal muscle reinforcement training is effective in improving the functions of the patients' muscles, thus increasing their quality of life.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

A Study on the Usefulness of Subjective Lumbar Instability Factor for Respiratory Pattern Change and Abdominal Mobility in Peoples with CLBP (만성허리통증자의 호흡 패턴과 배부 운동성 변화에 대한 주관적 허리부위 불안정성 요소의 유용성에 관한 연구)

  • Ki, Chul;Lee, Kwan-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.206-214
    • /
    • 2020
  • This study examined the correlation between the respiratory pattern change (RPC) and abdominal mobility (AM) according to the positive result of the subjective lumbar instability factor (SLIF) in people with chronic low back pain (CLBP). Thirty-six adults with CLBP participated in this study. Twenty-eight items of the SLIFs were examined, and the subjects were divided into three groups according to the positive response numbers (PRN). After the change lists were scored, three RPC scores [costo-diaphragmatic RPC (CDRPC), breath hold change (BHC), and total RPC (TRPC)] were obtained. The abdominal mobility (AM) was measured between the maximal inspiration and exhalation at the xiphoid (AM1) and the 10th rib (AM2) level of the trunk. The results showed that the RPC score and AM were compared according to the positive response number of SLIF, and the relationship between them was analyzed. A positive correlation was observed between the SLIF positive response number and CDRPC score, BHC score, and total RPC score, and a negative correlation was observed between the SLIFs positive response number and AM1 and AM2. Based on the results of this study, the combination of SLIF positive responses can be a predictor of non-physiological respiratory pattern changes in people with CLBP. Clinically, this prediction is expected to help save time for screening and improve the efficiency of therapy.

The Effect of Wind-instrument Centered Music Therapy on Respiration, Oral Motor and Articulation for Patients with Cervical Cord Injury - Case Study - (취주악기를 사용한 음악치료가 경수손상환자의 호흡, 구강운동 및 조음에 미치는 영향 -사례연구-)

  • Kim, Tai youn;Park, Shin ae;Lee, Yong seok
    • 재활복지
    • /
    • v.21 no.1
    • /
    • pp.233-252
    • /
    • 2017
  • The purpose of this study is to investigate the influence on respiration, oral motor and articulation using wind-instrument centered music therapy for patients with cervical cord injury who need continuous train of respiratory muscle. Three patients with cervical cord injury who needed continuous training of respiratory muscle were selected and post data was analyzed. The harmonica using both exhalation and inspiration was selected as an wind-instrument. Each session was taken 30 ~ 40 minutes, once a week from total 6 weeks with small group. Material about every session's work was provided for individual to maintain practice after program. Oral motor and articulation test was done to assess reflecting features of maximal expiratory flow and wind-instrument of factor related breath. Maximal expiratory flow has increased by average 25ml more, articulation has increased by 3.16 points more and the movement of oral motor has increased 11.67 points more than pre-test from the analyzation. In the comparison of the details, the increase of oral motor function was confirmed from scores on the jaw and tongue except for the lips. Based on the results of this study, this study suggests that wind-instrument centered music therapy will be a practical and effective intervention for respiratory rehabilitation in patients with cervical cord injury.

Epidemiology of anaphylaxis in Korean children (소아청소년에서 아나필락시스의 역학)

  • Lim, Dae Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.351-354
    • /
    • 2008
  • Anaphylaxis is an acute systemic reaction caused by IgE-mediated immunological release of mediators from mast cells and basophils to allergenic triggers, such as food, insect venoms, and medications. An alternative definition was recently proposed as follows: anaphylaxis is a "condition caused by an IgE mediated reaction" that is "often life threatening and almost always unanticipated." The reaction can be severe enough to lead to the rapid onset of symptoms, including dizziness, upper airway occlusion, bronchial constriction, hypotension, urticaria, cardiovascular arrhythmias and possible cardiac arrest. The incidence or prevalence of anaphylaxis in Korean pediatrics has not known. Thus, Epidemiology of Anaphylaxis in Pediatrics based on the data from Korean Health Insurance Review and Assessment Service (KHIRA) from 2001 to 2007 and questionnaire to the member of Korean Academy of Pediatric Allergy and Respiratory Disease (KAPARD) who are working at the training hospitals was studied. The incidence of anaphylaxis under age 19 is 0.7-1.0 per 100,000 year-person. The causes of anaphylaxis based on data from KHIRA were unknown (61.7%), food (24.9%), medications (12.4%), and serum (1.0%).

Effect of Myofacial Releasing of Abdominal Muscles on Chronic Cough by Oriental Medical Treatment : 2 Cases Report (한방치료를 통한 복근군의 근막이완으로 호전된 만성기침환자 치험 2례)

  • Kim, Eu-Gene;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.3
    • /
    • pp.123-134
    • /
    • 2009
  • Objectives : We supposed that abdominal muscles are related to chronic cough, because abdominal pressure and respiratory muscles are influenced by abdominal muscle function. We have evaluated the effect of myofacial releasing of abdominal muscles with oriental medical treatment by experimenting two patients suffering from chronic cough. Methods : One patient was treated with acupuncture therapy and muscle stretching exercise for myofacial releasing of abdominal muscle. The other patient was treated with hot pack therapy and abdominal respiration training for myofacial releasing of abdominal muscle. Results and Conclusions : After oriental medical treatment of abdominal muscles in two cases, We figured out that the patients were on the mend. These results suggest that myofacial releasing of abdominal muscles using oriental medical treatment was effective in improving chronic cough.

Current trends in intravenous sedative drugs for dental procedures

  • Yoon, Ji-Young;Kim, Eun-Jung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • Anxiety and phobia in dental procedures are common deterrents for patients visiting the dental care unit. For these individuals, procedural sedation may aid in completion of dental treatments. In most cases, the patients are conscious during sedation, thereby allowing spontaneous ventilation. Intravenous sedation (IVS) is widely used during dental treatment to relieve patient anxiety. IVS is the most effective route of administration to achieve this goal, but it requires advanced training, more than that provided during undergraduate education. During IVS, rapid onset, repetitive drug administration, easy titration, and rapid recovery from sedation can be achieved. However, conscious sedation during IVS can result in deep sedation that can cause respiratory and cardiovascular depression. Therefore, the characteristics of intravenous sedatives should be known. The purpose of this review is to discuss the characteristics and usage of intravenous sedatives currently used for dental procedures.

Use of real-time ultrasound imaging for biofeedback of diaphragm motion during normal breathing in healthy subjects

  • Cho, Ji-Eun;Hwang, Dal-Yeon;Hahn, Joohee;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.3
    • /
    • pp.95-101
    • /
    • 2018
  • Objective: To determine if the provision of visual biofeedback using real-time rehabilitative ultrasound imaging (RUSI) enhances the acquisition and retention of diaphragm muscle recruitment during exercise. Design: Two group pretest posttest design. Methods: Thirty healthy subjects were randomly assigned to the verbal feedback group (VG, n=15) or the visual and verbal feedback group (VVG, n=15). The VG performed breathing exercises 10 times with verbal feedback, and the VVG also performed breathing exercises 10 times with verbal feedback and visual feedback with the use of RUSI to measure changes in diaphragm thickness (DT). For DT, the mid-axillary lines between ribs 8 and 9 on both sides were measured in standing, and then the chest wall was perpendicularly illuminated using a linear transducer with the patients in supine to observe the region between rib 8 and 9 and to obtain 2-dimensional images. DT was measured as the distance between the two parallel lines that appeared bright in the middle of the pleura and the peritoneum. After one week, three repetitions (follow-up session) were performed to confirm retention effects. Intra- and between- group percent changes in diaphragm muscle thickness were assessed. Results: In the VVG, the intervention value had a medium effect size compared to the baseline value, but the follow-up value decreased to a small effect size. In the between-group comparisons, during the intervention session, the VVG showed no significant effect on percent change of DT but had a medium effect size compared to the VG (p=0.050, Cohen's d=0.764). During the follow-up session, retention effect did not persist (p=0.311, Cohen's d=0.381). Conclusions: RUSI can be used to provide visual biofeedback and improve performance and retention in the ability to activate the diaphragm muscle in healthy subjects. Future research needs to establish a protocol for respiratory intervention to maintain the effect of diaphragmatic breathing training using RUSI with visual feedback.

Quality of Same-Day Sputum Smears Microscopy and Presumptive Tuberculosis Patients Drop-out at Health Facilities of Addis Ababa, Ethiopia

  • Taddese, Boja Dufera;Misganaw, Abay Sisay
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.1
    • /
    • pp.89-95
    • /
    • 2020
  • Background: Same-day sputum microcopy is recommended in areas where sputum smear microscopy external quality assessment (EQA) is effectively implemented and sturdy. In Addis Ababa, the status of EQA and drop-out of same-day sputum smear microcopy has not yet been assessed. The objective of this study was to assess the quality of same-day sputum smear microscopy and diagnostic drop-out of presumptive tuberculosis (TB) patients in health facilities (HFs) across Addis Ababa, Ethiopia. Methods: Amulti-analysis was conducted from September 2016 to July 2017 to determine the status of external quality assessment and diagnostic drop-out of presumptive TB patients registered for same-day sputum smear microscopy. Data was coded and entered in Microsoft Excel, and subsequently transferred and analyzed using SPSS version 20.0. Results: The drop-out of same-day sputum smear microscopy was 209 (6.2%). More than 33% of the specimens collected for purposes of same-day sputum smears were of poor quality. Among the selected HFs for the study: 13 (46.4%) used filter reagents prior to sputum smear staining while 75% of the selected HFs for the study used smear microscopy services interruption in a year. The sensitivity and specificity of the HFs participating in regional quality assessment scheme for the diagnosis of TB was 97.4% and 99.6%, respectively. Conclusion: The diagnostic drop-out of same-day sputum smear microscopy was high in Addis Ababa. Strengthening EQA, competency-based laboratory professionals training on sputum smear microscopy might reduce the reading errors in sputum smear. Awareness creation of the community on the benefits gained from completion of specimen provision for the same-day approach decreases diagnostic drop-out and enhances TB control program.

Development of a model for animal health monitoring system in Gyeongnam I. Design, data and frequencies of selected dairy cattle diseases

  • Kim, Jong-shu;Kim, Yong-hwan;Choi, Min-cheol;Kim, Gon-sup;Kim, Chung-hui;Park, Jeong-hee;Hah, Dae-sik;Heo, Jung-ho;Jeong, Myeong-ho;An, Dong-won
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.4
    • /
    • pp.730-737
    • /
    • 1999
  • A national animal health monitoring system(NAHMS) in Gyeongnam area was started from 1997 to develop statistically valid data for use in estimating disease frequencies in dairy cattle, and the associated costs. The objectives of this study were to : (1) discribe what was done to implement and maintain the system in Gyeongnam ; (2) present selected disease frequencies ; (3) discuss the epidemiological consideration of what was done and implications for the results obtained. Veterinary Medical Officers(VMOs-professors and graduate students from Gyeongsang National University, Faculty of Gyeongnam Livestock Promotion Institute, and Clinic veterinarians) served as data collectors. After training on current disease and management problems of dairy cattle, interview techniques, sampling methods, and data collection instruments, the VMOs participated in selection of the sample herds and data gathering. Forty of 167 dairy herds were selected randomly and the VMOs visited farms once a month for 12 months to collect data about management, disease, inventory, production, preventive treatment, financial and any other relevant data. Strict data quality control devices were used. Specific feed-back was developed for the producers and data collectors. Of the three age groups studied, cows had the greatest number of disease problems. The six disorders found most frequently were (from the highest to the lowest) breeding problems, clinical mastitis, birth problems, gastrointestinal problems. metabolic problems, and lameness. In young stock, respiratory, multiple system, breeding problems, and gastrointestinal problems were pre dominant, whereas in calves, gastrointestinal, respiratory, and integumental problems were major.

  • PDF