IGRT를 위한 비침습적인 호흡에 의한 장기 움직임 실시간 추적시스템 (A Non-invasive Real-time Respiratory Organ Motion Tracking System for Image Guided Radio-Therapy)

  • 김윤종;윤의중
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권5호
    • /
    • pp.676-683
    • /
    • 2007
  • A non-invasive respiratory gated radiotherapy system like those based on external anatomic motion gives better comfortableness to patients than invasive system on treatment. However, higher correlation between the external and internal anatomic motion is required to increase the effectiveness of non-invasive respiratory gated radiotherapy. Both of invasive and non-invasive methods need to track the internal anatomy with the higher precision and rapid response. Especially, the non-invasive method has more difficulty to track the target position successively because of using only image processing. So we developed the system to track the motion for a non-invasive respiratory gated system to accurately find the dynamic position of internal structures such as the diaphragm and tumor. The respiratory organ motion tracking apparatus consists of an image capture board, a fluoroscopy system and a processing computer. After the image board grabs the motion of internal anatomy through the fluoroscopy system, the computer acquires the organ motion tracking data by image processing without any additional physical markers. The patients breathe freely without any forced breath control and coaching, when this experiment was performed. The developed pattern-recognition software could extract the target motion signal in real-time from the acquired fluoroscopic images. The range of mean deviations between the real and acquired target positions was measured for some sample structures in an anatomical model phantom. The mean and max deviation between the real and acquired positions were less than 1mm and 2mm respectively with the standardized movement using a moving stage and an anatomical model phantom. Under the real human body, the mean and maximum distance of the peak to trough was measured 23.5mm and 55.1mm respectively for 13 patients' diaphragm motion. The acquired respiration profile showed that human expiration period was longer than the inspiration period. The above results could be applied to respiratory-gated radiotherapy.

간암의 방사선치료 시 호흡운동 감소장치(respiratory motion reduction device, RRD)의 유용성에 관한 연구 (Use of Respiratory Motion Reduction Device (RRD) in Treatment of Hepatoma)

  • 이석;성진실;김용배;조광환;김주호;장세경;권수일;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제19권4호
    • /
    • pp.319-326
    • /
    • 2001
  • 목적 : 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하는 영역으로 조사 체적이 증가된다. 이로 인하여 방사선 독성 및 정상조직 선량이 증가되며, 호흡으로 인한 환자자세의 변화로 인해 종양의 정확한 위치파악이 어렵게 된다. 본 연구에서는 호흡에 따른 장기 움직임 유형을 분석하여 호흡에 의한 장기의 움직임을 최소화 할 수 있는 호흡운동 감소장치를 고안하고 방사선치료 시 호흡운동 감소장치의 유용성을 평가해 보고자 하였다. 대상 및 방법 : 간암환자 10명을 대상으로 하여 MeV-Green과 벨트, 스티로폼판 등을 사용하여 호흡운동감소장치(respiratory motion reduction device, RRD)를 제작하였다. 내부장기의 이동정도는 모의치료 시에 관찰된 횡경막의 이동 정도로 평가하였으며 앙와위와 복와위 및 RRD의 사용 시 이동정도를 쏠아보았고, 각각의 경우에서 이동정도를 고려하여 방사선치료계획을 수립하였다. 선량체적 히스토그램(dose-volume histogram, DVH)을 통해서 전체 간 용적 중 처방선량의 $50\%$가 조사되는 정상간 용적을 구하였다. 결과 : 호흡에 따른 횡경막의 평균이동거리는 앙와위 자세에서 $16{\pm}1.9\;mm$ 이었고, 복와위 자세에서는 $12{\pm}1.9mm$임을 알 수 있었다. 복와위 자세에서 본원에서 자체 제작한 RRD를 사용한 경우에는 $5{\pm}1.4\;mm$으로 감소되었고, 벨트 고정장치의 추가 사용 시에는 $3{\pm}0.9\;mm$으로 감소하여 총 9 mm 감소함을 알 수 있었다. 방사선치료계획에 따른 DVH에서 처방선량의 $50\%$가 조사되는 정상간의 용적은 호흡운동감소장치를 사용하지 않은 경우에 앙와위 자세에서 $43.7\%$, 복와위 자세에서 $40\%$ 이었고, 호흡운동 감소장치를 사용한 경우에 복와위 자세에서 $30.7\%$, 여기에 벨트 고정장치를 추가 사용하였을 경우에는 $21\%$로서 전체 간 용적 중 방사선에 조사되는 정상 간 용적은 최대 $22.7\%$ 감소됨을 알 수 있었다. 결론 : 호흡에 따른 내부장기의 움직임을 최소화 할 수 있는 RRD를 사용하여 정상조직에 불필요하게 조사되는 방사선을 감소시킬 수 있었다.

  • PDF

Development of Respiratory Motion Reduction Device System (RMRDs) for Radiotherapy in Moving Tumor: Construction of RMRDs and Patient Setup Verification Program

  • Lee, Suk;Chu, Sung-Sil;Lee, Sei-Byung;Jino Bak;Cho, Kwang-Hwan;Kwon, Soo-Il;Jinsil Seong;Lee, Chang-Geol;Suh, Chang-Ok
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.86-89
    • /
    • 2002
  • The purpose is to develop a system to reduce the organ movement from the respiration during the 3DCRT or IMRT. This research reports the experience of utilizing personally developed system for mobile tumors. The patients clinical database was structured for 10 mobile tumors and patient setup error measurement and immobilization device effects were investigated. The RMRD system is composed of the respiratory motion reduction device utilized in prone position and abdominal strip device(ASD) utilized in the supine position, and the analysis program, which enables the analysis on patients setup reproducibility. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the normal tissue volume, field margins and dose volume histogram(DVH) using fluoroscopy and CT images. And, reproducibility of patients setup verify by utilization of digital images. When patients breathed freely, average movement of diaphragm was 1.2 cm in prone position in contrast to 1.6 cm in supine position. In prone position, difference in diaphragm movement with and without RMRDs was 0.5 cm and 1.2 cm, respectively, showing that PTV margins could be reduced to as much as 0.7 cm. With RMRDs, volume of the irradiated normal tissue (lung, liver) reduced up to 20 % in DVH analysis. Also by obtaining the digital image, reproducibility of patients setup verify by visualization using the real-time image acquisition, leading to practical utilization of our software. Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

열전쌍마스크를 이용한 호흡모사팬톰 연구 (Study of Respiration Simulating Phantom using Thermocouple-based Respiration Monitoring Mask)

  • 임상욱;박성호;이병용;이상훈;조삼주;허현도;신성수;김종훈;이상욱;권수일;최은경;안승도
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.217-222
    • /
    • 2005
  • 목적: 호흡동기치료, 호흡조절 방사선치료 등 호흡에 관련된 치료법의 연구를 위해 열전쌍마스크(Respiration Monitoring Mask: ReMM)를 이용한 호흡모사팬톰을 개발하였다. 대상 및 방법: 호흡신호에 따라 실시간으로 움직이는 호흡모사팬톰을 제작하였다. 열전쌍으로 환자의 호흡을 측정하고, 측정된 호흡 신호와 장기의 움직임을 비교 분석하여 팬톰의 성능을 평가하였다. 환자의 호흡 측정에는 본 원에서 개발한 ReMM을 사용하였으며, 호흡모사팬톰의 운동은 $RPM^{(R)}$(Real-time Position Management, Varian, USA)으로 측정하였다. 횡격막 부위의 장기 운동을 확인하기 위하여 X-선 투시기를 사용하였다. 결과: X-선 투시영상과 $RPM^{(R)}$으로 관찰한 장기의 움직임을 ReMM으로 측정한 호흡 신호와 비교했을 경우, 각각 표준편차 9.68% 및 8.53% 이내에서 일치하였다. 호흡 신호에 따른 팬톰 운동의 오차는 호흡진폭에 대하여 표준편차 8.52%이내에서 일치하였다. 결론: ReMM은 환자가 호흡을 하는데 불편함이 없었고, 열전쌍에서 발생되는 호흡 신호를 이용한 호흡모사 팬톰은 장기의 운동을 실시간으로 잘 모사하였다. 호흡모사전통은 호흡동기치료 등 다양한 치료법의 평가에 응용할 수 있을 것으로 기대한다.

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

Extra-phase Image Generation for Its Potential Use in Dose Evaluation for a Broad Range of Respiratory Motion

  • Lee, Hyun Su;Choi, Chansoo;Kim, Chan Hyeong;Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Kim, Seonghoon;Choi, Sang Hyoun;Lee, Soon Sung;Kim, Jina;Hwang, JinHo;Kang, Youngnam
    • Journal of Radiation Protection and Research
    • /
    • 제44권3호
    • /
    • pp.103-109
    • /
    • 2019
  • Background: Four-dimensional computed tomographic (4DCT) images are increasingly used in clinic with the growing need to account for the respiratory motion of the patient during radiation treatment. One of the reason s that makes the dose evaluation using 4DCT inaccurate is a change of the patient respiration during the treatment session, i.e., intrafractional uncertainty. Especially, when the amplitude of the patient respiration is greater than the respiration range during the 4DCT acquisition, such an organ motion from the larger respiration is difficult to be represented with the 4DCT. In this paper, the method to generate images expecting the organ motion from a respiration with extended amplitude was proposed and examined. Materials and Methods: We propose a method to generate extra-phase images from a given set of the 4DCT images using deformable image registration (DIR) and linear extrapolation. Deformation vector fields (DVF) are calculated from the given set of images, then extrapolated according to respiratory surrogate. The extra-phase images are generated by applying the extrapolated DVFs to the existing 4DCT images. The proposed method was tested with the 4DCT of a physical 4D phantom. Results and Discussion: The tumor position in the generated extra-phase image was in a good agreement with that in the gold-standard image which is separately acquired, using the same 4DCT machine, with a larger range of respiration. It was also found that we can generate the best quality extra-phase image by using the maximum inhalation phase (T0) and maximum exhalation phase (T50) images for extrapolation. Conclusion: In the present study, a method to construct extra-phase images that represent expanded respiratory motion of the patient has been proposed and tested. The movement of organs from a larger respiration amplitude can be predicted by the proposed method. We believe the method may be utilized for realistic simulation of radiation therapy.

움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발 (Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy)

  • 우상근;박노운;박승우;유정우;한수철;이승준;김경민;강주현;지영훈;엄기동
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.76-83
    • /
    • 2013
  • 진단 및 치료분야에서 호흡 움직임이 미치는 영향에 대한 연구는 외부 움직임을 관찰하여 실시되었으나, 이러한 외부 움직임은 내부 장기의 실제 움직임을 반영하지 못한다. 이에 본 연구에서는 개의 흉부 내 비침습적 이식이 가능한 인공 폐결절을 제작하여 동물실험에 대한 적용가능성을 확인하고 PET 영상 획득 및 방사선조사 시 움직임의 영향을 평가하고자하였다. 인공폐결절은 8 Fr 일회용 위장용 영양공급튜브를 개조하여 제작하였다. 제작된 결절모델은 마취된 개 4마리에 기관을 경유하여 기관지에 삽입한 뒤 방사선투시장치를 이용하여 위치를 확인하였다. PET 촬영용 인공폐결절은 내강에 $^{18}F$-FDG를 주입한 뒤 호흡운동 모사체에 장착하여 정지 상태, 10 rpm과 15 rpm의 종축 왕복운동간 PET 촬영을 실시하였다. 방사선조사용 인공폐결절은 유리선량계를 이식한 뒤 PET 촬영 시와 동일한 호흡운동 모사체에 장착하여 정지 상태, 10 rpm과 15 rpm의 종축 왕복운동간 1 Gy 선량을 조사하였다. 인공폐결절은 방사선투시장치 영상에서 실험동물의 후엽 근위부 세기관지에 이식되며 호흡에 따라 결절의 위치가 변화함을 확인하였다. PET 영상에서의 인공폐결절은 모사된 호흡 움직임에 따라 움직임에 의한 인공산물을 나타내었으며, 호흡동조게이트 시 SNR은 7.21로 기준영상의 SNR 10.15에 비해 감소하였으나 프로파일상 게이트영상의 영상계수는 정적영상에 비해 기준영상과 유사하여 PET 영상의 질을 개선함을 확인하였다. 방사선조사 실험간 인공폐결절 내 삽입된 유리선량계에 조사된 조사선량은 정지 상태와 10 rpm의 종축 왕복운동에서 0.91 Gy로 차이를 보이지 않았으나, 15 rpm의 종축 왕복운동에서 0.90 Gy로 오차범위 내 감소를 나타내었으며, 이온 전리함을 통한 조사선량 검출에서도 근소한 감소를 나타내었다. 본 실험에서 제작된 인공폐결절은 실험동물의 후엽 근위부 세기관지에 높은 재현성을 보이며 방사선투시 영상에서 폐의 내부 움직임을 반영하였다. PET 영상 내 움직임에 의한 인공산물이 관찰되며, 방사선 조사연구에서는 호흡운동이 미약한 영상 흐림을 일으킴을 확인하였다. 따라서 본 인공폐결절은 진단 및 치료분야에서 실험동물을 이용한 움직임 기반 진단 및 치료 평가에 유용한 도구로 사용될 것으로 기대된다.

호흡에 의한 내부 움직임의 영향이 있는 간에서의 실험적 선량 측정 (Dose perturbation measurements during the liver treatment with internal organ motion: Mathematical modeling and Experimental simulation)

  • 정진범;김연래;정원균;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.115-118
    • /
    • 2004
  • 우리의 연구는 호흡에 의해 움직임의 영향을 받는 장기 및 종양에 대해서 조사된 선량분포를 측정하는 것이다. 이 연구를 수행하기 위해, 사전연구로 이전에 발표된 논문을 토대로 호흡에 의해 장기 및 종양의 움직임 변위를 조사하였다. 그리고 조사된 데이터를 활용하여 호흡에 따른 움직임을 구동 시스템을 적용하여 구현하였다. 내부 움직임에 의한 선량분포의 변화를 측정하기 위해서 이 구동 팬톰 시스템을 사용하였다. 이 결과로부터 호흡에 환자의 조사되는 선량분포의 부정확 정도를 평가할 수 있었다.

  • PDF

호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가 (Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy)

  • 조윤진;전미진;신동봉;김종대;김세준;하진숙;임정호;이익재
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.85-93
    • /
    • 2012
  • 목 적: 호흡에 의한 장기의 움직임이 큰 흉부와 상복부에 위치한 종양의 토모테라피 치료 시 움직임을 최소화하기 위해 노력으로 호흡 조절 시스템을 적용하지만 여러 제약이 따라 이용이 제한적이었다. 이에 본 연구에서는 토모테라피 치료 시 효율적인 호흡 조절을 위한 ABCHES system의 적용 가능성 및 유용성을 평가해 보고자 하였다. 대상 및 방법: 본원에서 흉부와 상복부에 위치한 폐와 간, 쓸개, 췌장에 토모테라피 치료를 받은 5명의 환자를 대상으로 하였다. 모든 환자에게 ABCHES를 사용하여 자유 호흡법과 얕은 호흡법을 각각 교육한 후 치료 계획용 4D-CT를 실시하여 총 10개의 4차원 단층촬영영상을 획득 하였다. 한명의 전공의는 각 영상의 최대 흡기, 최대 호기, 호흡의 중간 위상, Average CT이미지에서 육안적으로 보이는 종양과 주변 정상장기를 그렸으며 MIM에서 선량체적 히스토그램과 종양의 움직임에 대한 정량적 분석을 실시하였다. 자유 호흡과 얕은 호흡 상태에서 장기의 움직임은 총 여섯 방향에서 평가하였고 주변 장기에 조사된 방사선량을 비교하였다. 결 과: 5명의 환자 중 호흡 조절 장치인 ABCHES를 이용하여 자유 호흡과 얕은 호흡 상태에서 장기의 움직임이 5 mm 이상 움직인 호흡은 자유 호흡이 12번인 반면 얕은 호흡에서는 2번으로 감소되었다. 선량 체적 히스토그램을 통한 비교 분석 결과 두 호흡간 치료 체적과 종양조직 주변 정상 장기 2개의 평균 선량 값과 정상조직에 방사선이 조사되는 용적에서 ABCHES를 이용한 얕은 호흡이 자유 호흡에 비해 모두 낮은 치료 결과 값을 확인 할 수 있었다. 결 론: ABCHES를 사용하여 규칙적이고 정확한 얕은 호흡을 함으로써 토모테리피 치료 시 유용성과 호흡에 따른 종양의 움직임을 최소화 할 수 있음을 확인 하였고, 주변 정상조직에 불필요하게 조사되는 방사선을 감소시킬 수 있었다.

  • PDF

호흡주기에 따른 방사선입체조형치료법의 개발 (Development of Conformal Radiotherapy with Respiratory Gate Device)

  • 추성실;조광환;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.41-52
    • /
    • 2002
  • 목적 : 호흡주기에 따른 위치변동 감지센서를 이용하여 종양의 위치가 일정워치에 있을 때만 방사선을 치료하는 호흡 동기치료기구를 제작하고 일정한 호흡주기 상태에서 수행된 CT simulation과 3차원 입체조형치료계획에 따라 방사선을 치료하는 시스템을 개발하고자 하였다. 호흡유무에 따른 종양의 치료 마진(margin)을 측정하고 계획용표적체적(planning target volume:PTV)의 크기에 따른 선량체적표(dose volume histogram:DVH)와 종양억제확률(tumor control probability:NTCP), 건강조직손상확률(normal tissue complication probability:NTCP) 및 선량 통계자료를 통하여 치료성과를 평가하고 선량증강 범위를 예측하고자 하였다. 대상 및 방법 : 종양이 비교적 작고 전이가 없는(T1N0M0) 5명의 폐암환자를 선택하여 X-선 조준장치를 이용하여 횡격막의 이동거리를 측정하는 방법으로 내부장기의 운동을 평가하였다. 호흡동기치료기구는 끌어당김 센서가 부착된 허리띠 모양으로 구성되었으며 이를 흉곽 또는 복부에 부착하여 호흡주기에 의한 흉곽의 크기변동에 따라 센서의 회로가 개폐되고 이것을 선형가속기의 조종간에 연결하는 간단한 기구로서 감도와 재현성이 높았다. 호흡을 배기한 후 일시적 호흡이 정지된 상태에서 Spiral-CT (PQ-5000)로 3차원 영상을 획득하고 Virtual CT-simulator (AcQ-SIM)에 의하여 종양의 위치와 주위 장기들을 확인 도시하였으며 3차원 치료계획장치(Pinnacle, ADAC Co.)를 이용하여 3차원 입체조형치료를 계획하였다. 치료계획의 평가는 호흡동기치료기구의 사용유무에 따른 PTV의 크기에 따라 최적 선량분포를 구사하였으며 각각의 DVH, TCP, NTCP 및 선량통계자료를 도출 비교 검토하였다. 결과 : X-선 simulation에서 폐암환자의 횡격막 이동은 약 1 cm에서 2.5 cm로서 평균 1.5 cm로 측정되었고 자유호흡시 PTV는 CTV (clinical target volume)에 약 2 cm 마진을 주었으며 호흡동기치료기구를 사용하였을 때는 0.5 cm 마진이 적당한 것으로 측정되었다. 종양의 PTV는 연장 마진의 거의 자승비로 증가하였으며 TCP의 값은 마진 범위 $(0.5\~2.0\;cm)$에 관계없이 거의 일정하였고 NTCP의 값은 마진 크기에 따라 평균 $65\%$로 급속히 증가하였다. 결론 : 호흡주기에 따른 위치변동 감지센서를 이용한 호흡동기치료기구는 종양의 위치가 일정할 때만 방사선이 조사되는 간단하고 정확한 장치로서 3차원 입체조형치료 및 강도변조방사선치료에서 매우 유용한 장치임을 확인할 수 있었다. 또한 호흡조절 방사선입체조형치료방법의 기술과 시술절차를 확립시키고 정량적인 선량평가를 위하여 DVH, TCP, NTCP 등의 정량분석과 종양의 투여 선량 증가량(dose escalation)을 예측하는 기초자료를 제공할 수 있었다.