• 제목/요약/키워드: Respiratory Monitoring

검색결과 292건 처리시간 0.024초

A Study on the Design of Real-Time Monitoring System Using IoT Sensor in Respirator

  • Shin, Woochang;Rho, Jungkyu
    • International journal of advanced smart convergence
    • /
    • 제9권3호
    • /
    • pp.169-175
    • /
    • 2020
  • A lot of research has been conducted on a system that collects and observes patients' health information in real time using Internet of Things (IoT) technology, and cares for and supports patients based on this. However, most studies have focused on underlying diseases such as diabetes or cardiovascular disease, and research on IoT systems to cope with respiratory infectious diseases such as COVID-19 is still insufficient. In a COVID-19 situation, the purpose of using an IoT respirator may vary depending on the user. In this paper, we design a system that can adequately cope with respiratory infectious diseases such as COVID-19 by applying IoT technology to respiratory protection. We categorize IoT respirator wearers into patients, medical staff, and self-quarantine persons, and define the purpose and use case of the IoT respirator system according to each classification. The proposed IoT respirator system was designed to achieve each purpose. We developed a prototype system consisting of a smart sensor, a communication module, and a non-motorized hooded respirator to show that the proposed IoT respirator system works.

Evaluation of the Quality of Care among Hospitalized Adult Patients with Community-Acquired Pneumonia in Korea

  • Hong, Ji Young;Kang, Young Ae
    • Tuberculosis and Respiratory Diseases
    • /
    • 제81권3호
    • /
    • pp.175-186
    • /
    • 2018
  • Pneumonia is an important cause of morbidity and mortality. Since 2014, the Health Insurance Review and Assessment Service (HIRA) has assessed the overall quality of care among hospitalized adult patients with community-acquired pneumonia (CAP) provided by all medical institutions in Korea. A committee of the Korea Academy of Tuberculosis and Respiratory Diseases developed the hospital inpatient quality measures set for CAP consisting of eight core measures and five monitoring measures. The composite measure score was calculated. The medical records of hospitalized adult patients ages 18 years or more with CAP from October to December 2014 were evaluated. The data of 523 hospitals (42 tertiary hospitals [8.0%], 256 general hospitals [49%], and 225 hospitals [43.0%]) and 15,432 cases (tertiary hospitals, 1,673 cases [10.8%]; general hospitals, 8,803 cases [57.1%]; hospitals, 4,956 cases [32.1%]) were analyzed. We found large variations among institutions in terms of performance of care measures for CAP. For the composite measure score, the mean value was 66.7 (tertiary hospitals, 98.5; general hospitals, 79.2; hospitals, 43.8). Despite significant differences in measure scores between tertiary, general hospitals and hospitals, no significant differences were found in mortality between hospitals. Further studies are needed to determine the care measures appropriate for CAP.

복부에서 측정하는 일회 호흡용적의 정확도 평가 (Accuracy Evaluation of Tidal Volume Measured on the Abdomen)

  • 이인광;김성식;장종찬;김군진;김경아;이태수;차은종
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1298-1303
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. This study implemented respiratory monitoring system with the conductive rubber cord in the patient's pants in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%$ $CO_2$ was inhaled and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation significantly increased the tidal volume in normal physiological state with the subject unawared. The tidal volume estimated from the abdominal dimension change linearly correlated with the tidal volume measured by a pneumotachometer with a correlation coefficient of 0.88. Customized calibration for each subject resulted in relative errors less than 10%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Pysiological Responses of Diploid and Triploid Far Eastern Catfish, Silurus asotus to Water Temperature Stress

  • Lee, Hyo Bin;Kim, Dong Soo;Gil, Hyun Woo;Park, In-Seok
    • 한국발생생물학회지:발생과생식
    • /
    • 제22권2호
    • /
    • pp.165-174
    • /
    • 2018
  • The aim of study is to contribute to this knowledge-base by investigating the respiratory function, the metabolic rate and the difference of physiological responses un-der low water temperature ($20^{\circ}C{\rightarrow}15^{\circ}C$) stress be-tween diploid and triploid far eastern catfish, Silurus asotus. During the 48 hrs of water temperature stress exposure time, the respiratory frequencies, $CO_2$ and ${NH_4}^+$ concentrations of diploid had higher values than those of triploid (p<0.05). However, pH of triploid was higher than those of diploid (p<0.05), and oxygen consumption rate was not different between diploid and triploid (p>0.05). The level of plasma cortisol and plasma glucose of triploid was lower than those of the diploid (p<0.05). However, in case of lactic acid, there were not significant between triploid and diploid (p>0.05). These results suggest that diploid was more sensitive for low water temperature stress response than triploid in this species.

호흡-바이오피드백 앱 개발을 위한 PPG기반의 호흡 추정 알고리즘 (Breathing Information Extraction Algorithm from PPG Signal for the Development of Respiratory Biofeedback App)

  • 최병훈
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.794-798
    • /
    • 2018
  • There is a growing need for a care system that can continuously monitor, manage and effectively relieve stress for modern people. In recent years, mobile healthcare devices capable of measuring heart rate have become popular, and many stress monitoring techniques using heart rate variability analysis have been actively proposed and commercialized. In addition, respiratory biofeedback methods are used to provide stress relieving services in environments using mobile healthcare devices. In this case, breathing information should be measured well to assess whether the user is doing well in biofeedback training. In this study, we extracted the heart beat interval signal from the PPG and used the oscillator based notch filter based on the IIR band pass filter to track the strongest frequency in the heart beat interval signal. The respiration signal was then estimated by filtering the heart beat interval signal with this frequency as the center frequency. Experimental results showed that the number of breathing could be measured accurately when the subject was guided to take a deep breath. Also, in the timeing measurement of inspiration and expiration, a time delay of about 1 second occurred. It is expected that this will provide a respiratory biofeedback service that can assess whether or not breathing exercise are performed well.

The "Warm Zone" Cases: Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters

  • Caban-Martinez, Alberto J.;Kropa, Bob;Niemczyk, Neal;Moore, Kevin J.;Baum, Jeramy;Solle, Natasha Schaefer;Sterling, David A.;Kobetz, Erin N.
    • Safety and Health at Work
    • /
    • 제9권3호
    • /
    • pp.352-355
    • /
    • 2018
  • Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the "warm zone" of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.

외래치료실에서의 근위축성 측삭경화증 환자(ALS)의 전신마취 하치과 치료시 마취관리 (Anesthetic Management of an Amyotrophic Lateral Sclerosis Patient Undergoing Dental Care in Daysurgery Center)

  • 김한수;이숙영;최은혜;김승오
    • 대한치과마취과학회지
    • /
    • 제13권4호
    • /
    • pp.195-201
    • /
    • 2013
  • Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease caused by the degeneration of upper and lower motor neurons. The disorder causes muscle weakness and atrophy in airway muscles including pharyngeal, laryngeal and other respiratory muscles. The response to muscle realxant is also altered in patients with ALS. Because of the inherent muscle weakness and associated respiratory insufficiency, particular attentions are needed in anesthetic management of ALS patients. We used proper doses of inhalation anesthetics and opioids under EEG-entropy (electroencephalography-entropy)-monitoring without the use of muscle realxants in the anesthetic management of a patient with ALS. The patient early recovered and was discharged on the same day without any respiratory complications.

Concise Clinical Review of Hematologic Toxicity of Linezolid in Multidrug-Resistant and Extensively Drug-Resistant Tuberculosis: Role of Mitochondria

  • Oehadian, Amaylia;Santoso, Prayudi;Menzies, Dick;Ruslami, Rovina
    • Tuberculosis and Respiratory Diseases
    • /
    • 제85권2호
    • /
    • pp.111-121
    • /
    • 2022
  • Multidrug-resistant tuberculosis (MDR-TB) is caused by an organism that is resistant to both rifampicin and isoniazid. Extensively drug-resistant TB, a rare type of MDR-TB, is caused by an organism that is resistant to quinolone and one of group A TB drugs (i.e., linezolid and bedaquiline). In 2018, the World Health Organization revised the groupings of TB medicines and reclassified linezolid as a group A drug for the treatment of MDR-TB. Linezolid is a synthetic antimicrobial agent in the oxazolidinone class. Although linezolid has a good efficacy, it can cause substantial adverse events, especially hematologic toxicity. In both TB infection and linezolid mechanism of action, mitochondrial dysfunction plays an important role. In this concise review, characteristics of linezolid as an anti-TB drug are summarized, including its efficacy, pathogenesis of hematologic toxicity highlighting mitochondrial dysfunction, and the monitoring and management of hematologic toxicity.

간암 호흡동조 방사선치료 환자의 호흡신호분석 (Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy)

  • 강동임;정상훈;김철종;박희철;최병기
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.23-30
    • /
    • 2015
  • 목 적 : 외부표지자 호흡움직임 측정 장치(RPM; Real-time Position Management, Varian Medical System, USA)를 이용한 간암 호흡동조 방사선치료 시 호흡신호와 방사선 조사 시간 및 실제 조사된 호흡위상을 분석하여 호흡움직임 측정 장치를 이용한 호흡동조 방사선 치료의 정확도를 평가하였다. 대상 및 방법 : 2014년 5월부터 9월까지 Novalis Tx.(Varian Medical System, USA)와 RPM을 이용하여 간암 호흡동조 방사선치료(Duty Cycle 20%, Gating window 40% ~ 60%)를 시행한 환자 총 16명의 치료 시 기록된 호흡움직임을 분석하였다. RPM에 기록된 외부표지자의 호흡움직임을 후행적 분석을 통해 호흡위상으로 재구성하였으며, 재구성된 호흡위상을 이용하여 기록된 Beam-on Time과 Duty Cycle에 대해 RPM을 사용한 호흡동조 방사선치료의 예측 정확도를 분석하고, 호흡움직임의 재현성에 따른 Duty Cycle과 예측 정확도의 상관관계를 분석하였다. 결 과 : 대상 환자 16명의 치료계획 시와 실제 치료 시 호흡주기 차이는 평균 -0.03초(범위 -0.50초 ~ 0.09초)로 분석되었으며 두 호흡간의 통계적 차이는 확인할 수 없었다(p=0.472). 치료 시 평균 호흡주기는 4.02 sec (${\pm}0.71sec$), 치료 중 호흡주기 표준편차의 평균값은 7.43%(범위 2.57% ~ 19.20%)로 분석되었다. 실제 Duty Cycle은 평균 16.05%(범위 13.78% ~ 17.41%)로 나타났고 이 중 후행적 분석을 통해 평균 56.05%(범위 39.23% ~ 75.10%)가 계획된 호흡위상(40% ~ 60%)에서 조사되었음을 확인하였다. 호흡주기의 표준편차와 Duty Cycle과 계획된 호흡위상에서 조사된 비율의 상관관계는 각각 -0.156 (p=0.282)와 -0.385 (p=0.070)으로 분석되었다. 결 론 : 본 연구는 실제 치료 중 기록된 외부표지자의 호흡움직임을 후행적으로 분석하여 치료 중 호흡움직임의 재현성 및 Duty Cycle, 계획된 호흡동조창에서의 실제 치료 비율 등을 확인하였다. 4DCT를 이용한 치료계획과의 오차를 최소화하고 효율적인 치료를 위해 호흡훈련 및 호흡신호 모니터링의 강화가 필요 할 것으로 판단된다.

  • PDF

서울시 일부 택시기사의 이산화질소 개인폭로량에 관한 연구 (Personal $NO_{2}$ Exposures of Taxi Drivers)

  • 김윤신;전후민;홍승철
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.9-16
    • /
    • 1991
  • Personal NO$_{2}$ expousre and time activity patterns were measured during March, 1991 for 46 taxi drivers in the Seoul area. Badge-type personal samplers were worn for 24 hours by taxidrivers for monitoring personal expousre to NO$_{2}$. A standard respiratory questionnaire was administered and pulmonary function test was performed using a protable spirometry. The mean concentrations of personal NO$_{2}$ expousres of taxi drivers were 0.55ppm. Personal NO$_{2}$ exposures of taxi drivers were seemed to be higher in longer period of driving, smokers, and use of LP gas in homes. Prevalence rate of respiratory symptoms and the level of pulmonary function(FEV$_{1.0}$ and FVC) seemed to be related to higher personal NO$_{2}$ concentrations. It is concluded that persoanl NO$_{2}$ expousres of taxi drivers are probably affected by indoor NO$_{2}$ levels of a tax/and their common activities.

  • PDF