• Title/Summary/Keyword: Respirators

Search Result 79, Processing Time 0.021 seconds

Sphingomonas Paucimobilis : A Rare Infectious Agent Found in Cerebrospinal Fluid

  • Goker, Tuncer;Asik, Rahile Zulal;Yilmaz, Muhammet Bahadir;Celik, Ilhami;Tekiner, Ayhan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.481-483
    • /
    • 2017
  • Sphingomonas paucimobilis (S. paucimobilis) is a gram negative bacillus. It has existed in soil, drinking water and plants. It has been isolated from distilled water tanks, respirators, and hemodialysis devices at the hospital setting. Patients with chronic disorders or immune suppression may be susceptible to infections with it. This microorganism has also been reported to infect healthy persons. Both nosocomial and community-acquired infections have been reported. So far, a variety of infections have been reported, including sepsis, septic pulmonary embolism, septic arthritis, peritonitis, and endophthalmitis. Only 2 cases of meningitis have been reported so far in the literature. So far, no previous reports of culture proliferation have been reported in patients with external ventricular drains, as was the case in our patient. Therefore, our case is the first to have S. paucimobilis proliferation in cerebrospinal fluid culture during intensive care unit stay for an external ventricular drain.

A Study on the Measurement of Respiratory Rate Using a Respirator Equipped with an Air Pressure Sensor

  • Shin, Woochang
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.240-246
    • /
    • 2022
  • In order to measure the respiratory rate, one of the major vital signs, many devices have been developed and related studies have been conducted. In particular, as the number of wearers of respirators increases in the COVID-19 pandemic situation, studies have been conducted to measure the respiratory rate of the wearer by attaching an electronic sensor to the respirator, but most of them are cases in which an air flow sensor or a microphone sensor is used. In this study, we design and develop a system that measures the respiratory rate of the wearer using an air pressure sensor in a respirator. Air pressure sensors are inexpensive and consume less power than the other sensors. In addition, since the amount of data required for calculation is small and the algorithm is simple, it is suitable for small-scale and low-power processing devices such as Arduino. We developed an algorithm to measure the respiratory rate of a respirator wearer by analysing air pressure change patterns. In addition, variables that can affect air pressure changes were selected, and experimental scenarios were designed according to the variables. According to the designed scenario, we collected air pressure data while the respirator wearer was breathing. The performance of the developed system was evaluated using the collected data.

Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers (약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례)

  • Je-Hun Kim;Ki-Youn Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.

Evacuation Safety Evaluation of High School according to Hydrogen Fluoride Leakage

  • Boohyun Baek;Sanghun Han;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.255-266
    • /
    • 2024
  • The purpose is to evaluate evacuation safety by simulating the toxic effects of hydrogen fluoride leaks in areas surrounding national industrial complexes and to suggest alternatives for areas that do not satisfy evacuation safety. For human casualties caused by hydrogen fluoride leakage accidents, Available Safe Egress Time (ASET) is calculated by the toxic effects quantified with the Areal Locations of Hazardous Atmospheres (ALOHA), an off-site consequence assessment program. The Required Safe Egress Time (RSET) is calculated through Pathfinder, an evacuation simulation program. Evacuation safety is assessed by comparing ASET and RSET. The ALOHA program was used to evaluate the time to reach AEGL-2 concentration in 12 scenarios. The Pathfinder program was used to assess the total evacuation time of the high school among specific fire-fighting objects. Of the 12 accident scenarios, ASET was larger than RSET in the worst-case scenarios 1 and 9. For the remaining 10 accident scenarios, the ASET is smaller than the RSET, so we found that evacuation safety is not guaranteed, and countermeasures are required. Since evacuation safety is not satisfactory, we proposed to set up an evacuation area equipped with positive pressure equipment and air respirators inside specific fire-fighting objects such as the high school.

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

A Survey on the Management of Chemical Substances and Airborne Concentration in Laundries Exposed to Organic Solvents (일부 세탁소의 유기용제 관리실태 및 공기중 노출농도에 관한 조사)

  • Roh, Young-Man;Kwon, Gi-Bum;Park, Seoung-Hyun;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.70-77
    • /
    • 2001
  • This study was conducted to identify the current status of occupational safety and health by checklist and to evaluate the airborne exposure to chemicals and to provide the appropriate recommendation for safety and health of laundries. A total of 20 laundries located in tile Gyungi district area were surveyed from July 20 to September 15, 2000. The prevalence of laundries having a stove and gas range were found to be 25 % and 55 %, respectively. Smoking is not allowed in 60 % of the laundries. Only 10 % of dry-cleaners were isolated. Ventilation systems in laundries had not been annually inspected. Most of the workers didn't put on respirators, MSDS were not available, and storage bottles did not contain warning labels. The bulk samples of dry cleaning agent include many chemicals that are not controlled by the MOL in Korea. The detected airborne organic solvents in the laundries were benzene, toluene, p-xylene, m-xylene, o-xylene, perchloroethylene, and 2-butoxy ethanol. The airborne concentrations of organic solvents were much less than the occupational exposure limits proposed by the Ministry of Labor(MOL) in Korea. But the concentrations of benzene exceeded the TLV of ACGIH. This study showed that the current status of occupational safety and health was not appropriate for workers in laundries. It is recommended that laundry workers should be educated for the treatment and storage of hazardous organic solvents to improve the occupational safety and health of the working environment as well as MSDS usage. Also, extended research and survey for the organic solvents that are not controlled by the MOL has to be conducted.

  • PDF

A Study on Filtration Efficiency of Several Dust Masks for Stainless Steel arc Welding fume (방진마스크의 Stainless steel arc 용접흄 여과효율에 관한 연구)

  • Song, Kyung-Seuk;Kwon, Yong-Shick;Han, Kuy-Tae;Chung, Kyu-Hyuck;Lee, Yong-Mook;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2001
  • The purpose of this study was to investigate for filtration efficiency of several dust masks, comparing with filtration efficiency certified by KOSHA(Korea Occupational Safety & Health Agency), and to require of the right use of protective respirators. Using a welding fume generator and chamber, several dust masks, which were widely used in the workplaces in korea, were tested for their filtering efficiency for stainless steel arc welding fume. The filtration efficiency testing system consisted of a welding fume generator, a chamber and a filtration unit. The filtration unit was made of a mask which was inserted into the sampling cassette and another sampling cassette, which contained mixed cellulose ester filter paper. These two cassettes were connected with tubing. Stainless steel arc welding fume generator was delivered into an chamber. The welding fume in the chamber was passed into the filtration unit with flow rate of 30 liter/min. The welding fume filtration efficiency was evaluated by gravimetric measurement. Metal concentrations in the welding fume before and after filtration were measured with inductive coupling plasma analyzer. Following results were obtained: Filtration efficiency of welding fume for common hygienic mask was 63.82% and the average efficiencies for A, B, C, D, E, F and G masks were 94.62%, 96.58%, 83.20%, 82.76%, 77.25%, 86.55% and 93.22%, respectively. Our results indicate that dust masks used widely in the welding workplaces in korea are not proper for protecting worker's health and then the use of fume mask should be required.

  • PDF

Breakthrough behaviour of NBC canister against carbon tetrachloride: a simulant for chemical warfare agents

  • Srivastava, Avanish Kumar;Shah, D.;Mahato, T.H.;Singh, Beer;Saxena, A.;Verma, A.K.;Shrivastava, S.;Roy, A.;Yadav, S.S.;Shrivastava, A.R.
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.109-114
    • /
    • 2012
  • A nuclear, biological, chemical (NBC) canister was indigenously developed using active carbon impregnated with ammoniacal salts of copper (II), chromium (VI) and silver (I), and high efficiency particulate aerosol filter media. The NBC canister was evaluated against carbon tetra chloride ($CCl_4$) vapours, which were used as a simulant for persistent chemical warfare agents under dynamic conditions for testing breakthrough times of canisters of gas masks in the National Approval Test of Respirators. The effects of $CCl_4$ concentration, test flow rate, temperature, and relative humidity (RH) on the breakthrough time of the NBC canister against $CCl_4$ vapour were also studied. The impregnated carbon that filled the NBC canister was characterized for surface area and pore volume by $N_2$ adsorption-desorption isotherm at liquid nitrogen temperature. The study clearly indicated that the NBC canister provides adequate protection against $CCl_4$ vapours. The breakthrough time decreased with the increase of the $CCl_4$ concentration and flow rate. The variation in temperature and RH did not significantly affect the breakthrough behaviour of the NBC canister at high vapour concentration of $CCl_4$, whereas the breakthrough time of the NBC canister was reduced by an increase of RH at low $CCl_4$ vapour concentration.

A Study on the Effect of Compressed Air Using Air-breathing Upon Human (공기호흡기용 압축공기가 인체에 미치는 영향에 대한 연구)

  • 이창우;이용재;현성호;성재만;최돈묵;윤명오
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.95-102
    • /
    • 2004
  • This paper has analyzed compressed air-breathing that fire fighters use in Korea. And the local and the foreign standards for compressed air have been compared. Through the survey, it has been found that over 75% of all the respondents have ever had simple abnormal symptoms after wearing air respirators, and among the abnormal symptoms, nausea and headache are most frequent. Maintenance and exchange of compressor filters were poor and it can be another cause of abnormal symptom of fire fighters. Korea does'nt have any particular standards for compressed air-breathing, and the compressed air that is used by fire fighters is not different from air for industrial use. However, advanced countries like Europe, Canada and America, they have special standards for compressed air-breathing that fire fighters use. Through the analysis of components of the compressed air used in Korea, it has been found that all the samples have more water than the international standards.