• 제목/요약/키워드: Respirator performance test

검색결과 11건 처리시간 0.023초

호흡기보호구의 밀착계수와 안면구조의 관계 (Correlation of Fit Factors for Respirators and Anthropometric Dimension)

  • 한돈희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권3호
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF

호흡기보호구의 밀착도 검사와 안면규격 Panel의 개발 (Fit Testing for Respirators and Development of Fit Test Panels for Koreans)

  • 한돈희
    • 한국산업보건학회지
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 1999
  • Even though there is no fit test regulations in Korea, in many developed countries, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Due to no regulation for fit test, a lot of Korean workers wearing respirators may be potentially exposed to hazards. Anthropometric test panels for testing the fit of respirators are very important to develop respirators fitted properly for Korean workers. To evaluate the fitting performance, 304 workers (272 males, 32 females) and 536 students (268 male, 268 females) were fit tested for 4 full-facepieces (2 domestic-made S, C, and 2 foreign-made T, N), 2 half masks (1 domestic-made S, and 1 foreign-made T) and 3 quarter masks (2 domestic-made S, C, and 1 foreign-made T) with PortaCount 8020. Fit factors of foreign-made masks were higher than those of domestic-made masks in all types. Males were fitted more properly than females. A facial dimension survey of 364 workers (339 males, 25 females) and 158 students (69 males, 89 females) was conducted to develop test panels for fit testing. Subjects were selected on the basis of face length and face width to wear full-facepiece masks in test. For testing half- and quarter masks, face length and lip length were used. Test panels containing 25 male-and-female subjects and 16 male subjects were respectively developed for full-facepiece, and half-and quarter masks to represent a majority of population surveyed.

  • PDF

Development of Korean Head forms for Respirator Performance Testing

  • Seo, Hyekyung;Kim, Jennifer Ivy;Kim, Hyunwook
    • Safety and Health at Work
    • /
    • 제11권1호
    • /
    • pp.71-79
    • /
    • 2020
  • Background: Protection from yellow dust and particulate matter is ensured by the use of respirators among the Korean citizens and workers. However, the manikins used to test the performance of the same were manufactured considering western facial specifications owing to which they do not represent Korean facial characteristics. Methods: Analysis of the data from the 6th 3D anthropometric survey of Koreans (Size Korea; 2010-2013) of 4,583 people aged 7 to 69 years was performed to obtain their facial dimensions. We subsequently clustered 44 facial measurements using Design X software, followed by the creation of the cluster centroid. Results: Three 3D head forms were developed-small, medium, and large, and their images were stored in ".stl" format for 3D printing. The facial widths and lengths of the three head forms were 127.1 mm × 90.6 mm, 143.2 mm × 104.0 mm, and 149.1 mm × 120.2 mm, respectively. Conclusion: We developed manikin head forms according to the facial dimensions of the Korean population, which was essential in evaluating respiratory protective equipment. These head forms can be used to test the performance of respirators considering the facial dimensions of the Korean population.

산소 공급압력 변화에 따른 운반형 인공호흡기의 성능 특성 연구 (Performance Characteristics of Portable Resuscitator with the Change of supply Oxygen Pressure)

  • 김영수;김민욱;박용환
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.87-91
    • /
    • 2016
  • 최근 우리나라의 인구구조가 표주박형태의 고령화 사회로 변화함에 따라 급사의 원인이 되는 심장질환의 발생이 고령이 될수록 증가하고 있다. 심정지나 호흡이 정지된 환자에게 사용되는 인공호흡기중 전 세계적으로 보급되고 있는 공급되는 산소의 압력만으로 자동으로 작동되는 휴대용 인공호흡기의 필요성이 증가하고 있다. 이러한 휴대용 인공호흡기의 구성품 및 인공호흡기에 중요시되는 성능요구사항에 따른 시험방법을 제시하고 그에 따른 인공호흡기 내부감압셋팅 변화조건에 따른 최적 성능요구조건에 적합한 내부 감압조건을 찾고자 한다.

고효율 호흡보호구의 나노물질 입경별 제거 효율 (Fractional efficiency of Nanomaterials for the High efficiency respiratory filters)

  • 이광재;지준호;김원근;육세진;김종규;김정호
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2016
  • 본 연구에서는 호흡용 보호구 필터의 나노물질에 대한 여과특성을 측정하기 위해서 소금(NaCl)과 은나노입자(Ag)를 대상으로 입경별 집진효율을 평가하였다. 호흡용 보호구 필터는 특급 방진마스크와 1급 방진마스크의 두 가지 안면부 여과식 방진마스크인 사용하였고, 마스크의 배기밸브 부분을 제외한 필터 여재 부분을 직경 47 mm로 잘라내어 필터홀더에 부착하여 입경별 입자제거효율을 시험하였다. 시험입자는 일반적으로 시험 입자로 사용되는 소금입자는 분무형 입자발생장치를 사용하여 발생하였고 중화기를 통과시켜 입자의 하전특성을 볼츠만 분포로 만들어 공급하였다. 은나노입자의 경우, 기화-응축 방법을 이용한 금속나노입자 생성방법인 ISO10801 방법을 사용하였다. 작업장의 은나노입자의 고농도 노출을 모사하기 위해, 중화기를 통과하지 않은 나노입자를 시험입자로 사용하였다. 은나노입자의 경우 소금입자로 만들기 어려운 20nm 이하의 입자를 안정적으로 효과적으로 만들어 시험에 적용하였고, 나노 크기에서도 매우 안정적인 데이터를 확보할 수 있었다. 1급 마스크 필터와 특급 마스크 필터에 대한 소금입자의 평가에서, 입경별 최소효율이 30~50nm 사이에서 나타나는 특성은 기존 연구와 비슷한 결과를 얻었다. 반면, 은나노입자의 경우 1급 마스크 필터와 특급 마스크 필터 모두에서 비슷한 크기의 소금 입자와 비교할 때 높은 효율을 나타냈다. 이것은 소금 입자의 경우 중화기를 통과시켜 시험입자로 사 용한 반면, 은나노입자의 경우 중화기를 통과시키지 않았기 때문이다. 본 연구에서는 작업장에서 은나노 입자가 고농도로 노출될 경우를 모사하여, 기화-응축에 의한 방법의 은나노입자 발생장치를 사용하였는데, 이 때 상대적으로 높게 대전된 입자들이 많이 만들어진다(Jung et al., 2006). 이로 인해, 정전필터인 마스크 필터의 포집 효과가 상대적으로 크기 때문에, 입경별 효율이 높아진 것으로 생각된다. 본 연구에서 평가한 1급 및 특급 방진마스크 여재의 최소 포집효율은 유럽 EN 149 기준인 95 LPM 유량 기준을 만족하는 것으로 나타났지만, 이것은 여재에 대한 평가 결과로, 실제 마스크에 대해서는 여재의 구조적인 불균일성이나 마스크를 착용하는 과정에서 밀착이 되지 않아 누출될 가능성은 마스크 사용에 고려되어야 한다. 불시에 발생할 수 있는 작업장 내 안전사고의 예방을 위하여 적절한 보호구의 선택과 올바른 착용 및 유지관리가 필요할 것으로 생각된다.

한국형 테스트 패널과 Static Headform Chamber 개발연구 (A Study on the Korean Fit Test Panel and Static Headform Chamber)

  • 서혜경;장호영;안하림
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.145-155
    • /
    • 2023
  • Objectives: A fit test panel is needed to identify the fit performance of a respirator and its face seal. This is a criterion for selecting subjects that can represent the facial characteristics of users. Although anthropometry data has been developed for people in United States and China it is not yet present in Korea. This study aimed to develop a Korean fit test panel and test headform. Methods: For the 7th and 8th waves of the Size Korea anthropometry data, facial measurements of 11,429 people aged 15 to 69 years were used for analysis. PCA and bivariate panel were classified using the ISO16976-2:2022(E) anthropometrics analysis method. Based on this result, a static headform was developemed and a fit test chamber was constructed. Results: Of the 11,429 Korean people used for principal component analysis, 11,300 were included in the ellipse, marking an acceptance rate of 98.87% on PCA panel. The face types were classified into five types. Among them, a large, medium, and small static headform were printed using a 3D printer. In addition, 10,985 people (96.12%) were included in the bivariate panel based on face length and face width. The y-axis (face length) boundary was 97.87 to 134.59 mm, and the x-axis (face width) boundary was 120.75 to 158.23 mm. Conclusions: Compared to the ISO analysis, the Korean principal component was narrower in the width item (PC1) and longer in the length item (PC2). For the future, it is necessary to conduct a fit test using the developed headform and chamber device to confirm the usefulness of this Korean test panel. Therefore, this study is considered valuable as basic research for Korean test panels.

의료용 N95 마스크 착용방법에 대한 교육 전·후 밀착계수 비교 (Comparison of Fit Factor for Healthcare Workers Before and After Training with the N95 Mask)

  • 김현욱;백정은;서혜경;이종은;명준표;이승주;이진호
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.528-535
    • /
    • 2014
  • Objectives: This study compares the differences of fit factors before and after training on the N95 mask. The results will be utilized to suggest the need of providing effective training on respirator use. Methods: A total of 49 study subjects were tested, comprised of nurses from a general hospital and undergraduate nursing students from a medical school. Anthropometric measurements of face length and face width were compared with the NIOSH(National Institute for Occupational Safety and Health) panel. Fit factors(FF) were measured with TSI Portacount Pro+8038 before and after on-site training regarding the proper use of respirators. The FF pass/fail criterion was set at 100. Results: Two subjects(4.1 %) passed the fit test before training on use of the N95. However, 36(73.5%) of the 49 passed the test after training. Overall the FF(GM(GSD)) was 13.4(3.2) before training, but improved to 106.6(2.1) after training, which was statistically significant. These findings suggest the efficacy of educational intervention, and the performance of the direct on-site training proved to be better than that of the traditional educational methods. Conclusions: This study showed the effect of on-site training of the N95 respirator among health care workers(HCW). Therefore, providing effective training on the use of N95 for HCWs before their work assignments will greatly reduce exposure to harmful agents. It is recommended that fit testing be mandated to check for adequate protection being provided by the given respirators.

방진 마스크 필터 교체와 성능 변화의 상관성 조사 (Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators)

  • 이헌용;박지훈;윤충식
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.

Importance-Performance Analysis와 Borich 요구도 분석 방법을 활용한 임상간호실무 교육 요구도: 일개 상급종합병원 일반병동 간호사 대상 (Education needs for clinical nursing practice using an Importance-Performance Analysis and Borich needs assessment model: Focused on nurses in the general wards of a tertiary hospital)

  • 이미라;김지영;김보연;박유연;한지유;이승희;이현주
    • 한국간호교육학회지
    • /
    • 제29권2호
    • /
    • pp.124-137
    • /
    • 2023
  • Purpose: This study's aim was to confirm the importance and performance of the clinical practice of nurses working in the general wards of a tertiary hospital and to analyze their educational needs. Methods: The study employed a descriptive research design, and a self-reported questionnaire was developed and used for nurses in a tertiary hospital. Data were collected from July 22 to July 29, 2022, analyzed by an independent t-test, paired t-test, and one-way ANOVA for the importance and performance of each clinical nursing practice according to general characteristics, and then a post hoc verification was performed by Scheffé's test. An Importance-Performance Analysis and Borich needs assessment model were used to analyze clinical nursing education needs. Results: Clinical nursing practice performance showed a significant difference according to length of total clinical career, time working in current department, and preceptor experience. According to the results of the Importance-Performance Analysis, neurological evaluation, and nursing intervention, artificial respirator and high-flow oxygen inhalation nursing, chemotherapy, emergency nursing, and cardiopulmonary resuscitation were identified as belonging to the "concentrate here" quadrant. All these items ranked in the top 10 in the Borich needs assessment model. Conclusion: Based on these results, the current education system should be reviewed, and short and long term education strategies based on educational needs should be established to strengthen the competence of nurses.

방사능 방호 제품에 대한 KOLAS 인증 방안 연구 - 마스크를 중심으로 (Study on KOLAS Certification Approach for Radiation Protection Products - Focusing on Masks)

  • 박남희;여욱현;홍성진
    • 한국재난정보학회 논문집
    • /
    • 제19권4호
    • /
    • pp.815-825
    • /
    • 2023
  • 연구목적: 본 논문은 방사선비상계획구역 내 거주하는 주민의 방사능재난 발생시 대피과정에서 사용할 수 있는 방호제품으로서 마스크를 개발하는 과정에서 KOLAS 인증을 받을 수 있는 방안을 연구하는 것이다. 연구방법: 각종 보고서와 논문, KOLAS 인정기구 및 각종 마스크 홈페이지 자료를 조사하여 연구하였다. 연구결과: 국내 방사능재난방재대책을 수립하여 주민보호조치를 강화하고 있으나 방호제품 보급은 갑상샘방호약품이 유일하다. 방사능재난에 대비하여 마스크와 같은 보조적인 지원용품 보급이 필요하다. 방호마스크를 공인인증할 수 있는 KOLAS 인정 공인기관이 없는 실정이다. 결론: 성능 인증 기준이 있는 마스크의 경우 산업용 방진마스크로 공인시험성적서를 발급받고 인증을 받은 후에 자체 기준으로 일반성적서를 받는 이중 과정을 거쳐서 마스크의 KOLAS 인증이 가능하다.