• Title/Summary/Keyword: Resonant circuit

Search Result 939, Processing Time 0.022 seconds

High-Efficiency DC-DC Converter using the Multi-Resonant-Circuit (다중공진회로를 이용한 고효율 DC-DC 컨버터)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.218-228
    • /
    • 2021
  • This paper presents the high-efficiency DC-DC converter using the multi-resonant-circuit. The proposed converter has the power topology of half-bridge and utilizes the multi-resonant-circuit that is composed of 2 inductors (LL) and 1 capacitor (C) to achieve high-efficiency. The multi-resonant-circuit forms each resonant circuit of series circuit type with each resonant frequency, according to the operation modes. This paper first describes the operation pirinciples of proposed converter by the operation modes and steady-state fundamental approximation modelling. Then it shows a design example of the proposed converter based on the principles. And it is validated that the proposed converter has the operation characteristics of high-efficiency DC-DC power conversion through the experimental results of prototype converter implemented by the designed circuit parameters.

A study on the Push-Pull type high frequency resonant inverter connected boost converter (부스터 컨버터가 결합된 Push-Pull형 고주파 공진인버터에 관한 연구)

  • 김해준;서철식;원재선;김동희;노채균
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.169-172
    • /
    • 2000
  • This paper describes a Push-Pull type high frequency resonant inverter composed of consolidation of boost converter circuit and resonant inverter circuit. By using a boost converter circuit, the proposed inverter can obtain a twice input voltage of resonant circuit and reduce a secondary turn ratios. also, by using both switching device of boost-converter and resonant circuit, the number of switching device can be reduced by half, the analysis of the proposed circuit was generally described by using normalized parameter and operating characteristics have been evaluated as to switching frequency and parameters. In the future, this proposed inverter shows that is can be practically used as a power source system for the lighting equipment of discharge lamp, induction heating applications.

  • PDF

Analysis of Hybrid Converter with Wide Voltage Range Operation

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1099-1107
    • /
    • 2019
  • A soft switching converter with wide voltage range operation is investigated in this paper. A series resonant converter is implemented to achieve a high circuit efficiency with soft switching characteristics on power switches and rectifier diodes. To improve the weakness of the narrow voltage range in LLC converters, an alternating current (ac) power switch is used on the primary side to select a half-bridge or full-bridge resonant circuit to implement 4:1 voltage range operation. On the secondary-side, another ac power switch is adopted to select a full-wave rectifier or voltage-doubler rectifier to achiever an additional 2:1 output voltage range. Therefore, the proposed resonant converter has the capacity for 8:1 (320V~40V) wide output voltage operation. A single-stage hybrid resonant converter is employed in the study circuit instead of a two-stage dc converter to achiever wide voltage range operation. As a result, the study converter has better converter efficiency. The theoretical analysis and circuit characteristics are verified by experiments with a prototype circuit.

The operational characteristics of the AT Forward Multi-Resonant Converter (AT 포워드 다중 공진형 컨버터의 동작 특성)

  • 김창선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.114-123
    • /
    • 1998
  • The multi-resonant converter(MRC) minimizes a parasitic oscillation by using the resonant tank circuit absorbed parasitic reactances existing in a converter circuit. So it si possible that the converter operated at a high frequency has a high efficiency because the losses are reduced. Such a MHz high frequency applications provide a high power density [W/inch3] of the converter. But the resonant voltage stress across a switch of the resonant tank circuit is 4~5 times a input voltage. This h호 voltage stress increases the conduction loss because of on-resistance of a MOSFET with higher rating. Thus, in this paper we proposed the alternated multi-resonant converter (AT MRC) differ from the clamp mode multi-resonant converter and applicated it to the forward MRC. The AT forward MRC can reduce the voltage stress to 2~3 times a input voltage by using two series input capacitor. The control circuit is simple because tow resonant switches are driven directly by the output pulse of the voltage controled oscillator. This circuit type is verified through the experimental converter with 48V input voltage, 5V/50W output voltage/power and PSpice simulation. the measured maximum voltage stress is 170V of 2.9 times the input voltage and the maximum efficiency of 81.66% is measured.

  • PDF

Analysis of partial resonant AC-DC converter for high power and power factor

  • Mun, Sang-Pil;Kim, Si-Lyur;Lee, ki-Youn;Hyun-Woo;Katsunori taniguchi, Katsunori-Taniguchi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.920-927
    • /
    • 1998
  • This paper proposed that an Analysis of a partial resonant AC-DC converter for high power and power factor operates with four choppers connecting to a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer are included to confirm the validity of the analytical results. The partial resonant circuit makes use of an inductor using step-down and a condenser of lose-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in a partial resonant circuit makes charging energy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used

  • PDF

Mathematical Analysis of LLC Series Resonant Converter with Current Doubler Rectifier using Coupled Inductor (Coupled Inductor를 활용한 배전류 정류 회로를 적용한 LLC 직렬 공진 컨버터의 수식화 해석)

  • Shin, Jung-Yoon;Hwang, Soon-Sang;Yoon, Byung-Chul;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.440-449
    • /
    • 2014
  • This study proposes an LLC series resonant converter with a current doubler using a coupled inductor as a rectification circuit for the secondary side. The current doubler circuit is generally used for a high-voltage input and low-voltage output circuit to obtain high efficiency with small transformer turn ratio. However, an inductive circuit is not generally used in the secondary side of an LLC series resonant converter. If inductive components exist on the secondary side, the resonant characteristics are changed through the secondary inductive circuit. Mathematical analysis shows that the secondary-side current doubler with coupled inductor is not affected by the resonant characteristic of the primary LLC if leakage inductance occurs in the coupled inductor. Results of the analysis are proven by simulation; an experiment is also conducted for the proposed circuit.

A Resonant Circuit Design of the Inverter for Induction Heating by Analysis of the Coupling Coefficient (결합계수 해석에 의한 유도가열용 인버터의 공진회로 설계법)

  • 이광직;김주홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.90-95
    • /
    • 1997
  • In designing a resonant circuit of the inverter which puts induction heating with high frequency to the load, an inductance L of the circuit, the coupling coefficient of a transformer transfering the output power to load, and the coupling coefficient of load circuit heating with coil affect to the output power of a resonant circuit, the circuit Q and the frequency. Those characteristics of the circuit are analyzed through Thevenan's equivalent circuit of the coupling coefficient type which is derived from the T-type equivalent circuit of a transformer. On this equivalent circuit, the impedance of a transformer referred to its primary side is not only proportional the square of turn ratio, nZ, but also the square of coupling coefficient, K2 This paper proposed a more accurate fundamental method to design a resonant circuit of the inverter by using the Thevenan's equivalent circuit.

  • PDF

A Soft switching method for Loss reduction of Inverter (인버터의 손실저감을 위한 소프트 스위칭기법)

  • 곽동걸;김영철;이현우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

Cost-effective Single Board PDP Sustaining Driver with Dual Resonant Method

  • Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.93-99
    • /
    • 2009
  • A new plasma display panel sustaining driver using single side sustaining technique with a dual resonant method is proposed in this paper. Since this circuit enables to keep device voltage stress same as the prior circuit, it can be a low cost circuit compared to a conventional driver. To integrate the sustaining function into one side with a single power source in the driver, a charge pump method is adopted to make negative sustaining voltage and to achieve dual resonant energy recovery on the sustaining modes.

Analysis of Characteristics for Current Resonant type Boost AC-DC Converter for PFC and Reducing Harmonics (역률개선과 고조파 저감을 위한 전류공진 승압형 AC-DC 컨버터의 특성 해석)

  • Ra, B.H.;Song, D.H.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.341-344
    • /
    • 2001
  • In this paper, the characteristics of the proposed converter are show by simulation. As a result, the power factor is improved and the results show the usefulness of the proposed circuit. To improve the hard switching at turn-off of the basic circuit, the circuit using a current resonant switch is proposed. In the proposed circuit, THD of the input current is reduced to 1.8 of the basic circuit. The mechanism of the THD reduction is clarified. That is because the on period becomes shorter at the peak of the source voltage. Using the simulation, the characteristics of the output voltage, current flowing the switch, and THD of the input current are investigated by changing the resonant circuit parameters. Criteria for choosing resonant parameters of smaller THD are obtained.

  • PDF