• Title/Summary/Keyword: Resonant Modes

검색결과 248건 처리시간 0.025초

Wind-induced responses of Beijing National Stadium

  • Yang, Q.S.;Tian, Y.J.
    • Wind and Structures
    • /
    • 제14권3호
    • /
    • pp.239-252
    • /
    • 2011
  • The wind-induced mean, background and resonant responses of Beijing National Stadium are investigated in this paper. Based on the concepts of potential and kinetic energies, the mode participation factors for the background and the resonant components are presented and the dominant modes are identified. The coupling effect between different modes of the resonant response and the coupling effect between the background and resonant responses are analyzed. The coupling effects between the background and resonant components and between different modes are found all negligible. The mean response is approximately analogous to the peak responses induced by the fluctuating wind. The background responses are significant in the fluctuating responses and it is much larger than the resonant responses at the measurement locations.

A New Half-bridge Resonant Inverter with Load-Freewheeling Modes

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.249-256
    • /
    • 2007
  • This paper presents a new circuit topology and its digital control scheme for a half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in load-freewheeling modes, the pulse-width modulation (PWM) method can be used for the output power control. The proposed half-bridge inverter is based on the resonant frequency-tracking algorithm with the goal of maintaining the unity of the output displacement factor of the load impedance even in varying conditions. In this paper, the operation principle, electrical characteristics, and detailed digital control scheme of the proposed half-bridge resonant inverter are described. The experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge inverter are presented and discussed.

3-Phase Quasi-Resonant Inverter의 동작모드 확장 (Expansion of Operating Mode of 3-Phase Quasi-Resonant DC Link Inverter)

  • 양순배;이진우;박민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-271
    • /
    • 1990
  • This paper describes a 3-Phase Quasi-Resonant DC Link Inverter (3-phase QRI), which has two operating modes, ie. inverting mode and rectifying mode. First the 3-Phase QRI is simplified and the resonant circuit is analyzed in comparison with two resonant DC-to-DC converters. This analysis shows that the maximum voltage of resonant capacitor is limited to twice the input voltage irrespective of operating modes. A new simple control method in rectifying mode is suggested, which does not require any other element in power circuit. The characteristic of 3-Phase Quasi Resonant Inverter has been verified by simulation using the proposed control method.

  • PDF

Design of a Dual-Band Bandpass Filter Using an Open-Loop Resonator

  • Im, Hyun-Seo;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • 제17권4호
    • /
    • pp.197-201
    • /
    • 2017
  • In this paper, we present a novel design for a dual-band bandpass filter (BPF) based on the conventional second-order, open-loop BPF. By adding series resonant circuits to the open ends of the resonator, we can create two resonant modes from the even and odd modes. One pair of the even and odd modes constitutes the upper passband, while the other pair constitutes the lower passband. By adding another series resonant circuit to the open-loop resonator, we can control the bandwidth of either the upper passband or the lower passband. We can replace the series resonant circuits with simple microstrip line resonators. A dual-band BPF working at both Wi-Fi bands (2.4 GHz and 5.8 GHz bands) is designed based on the proposed method and is tested. The measured and simulated results show excellent agreement.

2차원 유한차분-시간영역 방법을 이용한 평면형 전송선로의 고차 모드 분산 특성 해석 (Dispersion Analysis of Higher-Order Modes for Planar Transmission Lines Using the 2-Dimensional Finite-Difference Time-Domain Method)

  • 전중창;박위상
    • 한국전자파학회논문지
    • /
    • 제10권6호
    • /
    • pp.847-854
    • /
    • 1999
  • 본 논문에서는 2차원 유한차분 시간영역 방법을 사용하여 균일 평변 전송선로의 고차 모드 주파수 분산 특성을 해석하였다. 전자계 스펙트럼의 크기만을 사용하는 기존 방볍과는 달리, 퓨리에 계수의 크기 및 위상 특성을 동시에 사용함으로써, 다른 공진모드에 비하여 스펙트럼의 크기가 상대적으로 착을 경우에도 모드 식 별이 용이하도록 하였다. 수치해석 결과, 20 GHz 이내에서 스트립 선로에서는 고차 모드가 몇 개 발생되지 않았지만, 접지된 coplanar waveguide에서는 상당히 많은 고차 모드가 발생되며, 특히, 첫 번째 고차 모드가 기본 모드에 매우 근접해 았었다 이와 같이, 기본 모드와 고차 모드가 매우 근접하여 있는 경우 또는 고차 모드가 매우 많이 발생되는 평변형 전송선로의 해석에 본 연구에서 해석 방볍이 효과적으로 적용될 수 있다.

  • PDF

에너지저장 커패시터의 최적 충전을 위한 직렬공진형 컨버터의 운용 모드 비교 (Comparative Analysis of Charging Modes of Series Resonant Converter for an Energy Storage Capacitor)

  • 이병하;강태섭;차한주
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.394-400
    • /
    • 2012
  • In this paper, charging modes of series resonant converter for a high voltage energy storage capacitor are compared in terms of charging time, peak resonant current, normalized peak resonant current and voltage in each operation mode. Operating principles of the full bridge series resonant converter with capacitor load are explained and analyzed in discontinuous and continuous operation mode. Based on the analysis and simulation result, $0.6{\omega}_r$ < ${\omega}_s$ < $0.75{\omega}_r$ and $1.3{\omega}_r$ < ${\omega}_s$ < $1.4{\omega}_r$ are evaluated to the best range of switching frequency for charging of an high voltage energy storage capacitor. 1.8 kJ/s SRC prototype is assembled with TI 28335 DSP controller and 40 kJ, 7 kV energy storage capacitor. Design rules based on the comparative analysis are verified by experiment.

부한 환류모드를 갖는 새로운 반 브리지 공진형인버터 (A New Resonant H/B Inverter Having Load Freewheeling Modes)

  • 연재을;조규민;오원석;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.153-156
    • /
    • 2004
  • This paper presents a new circuit topology of the half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in the load freewheeling modes, pulse width modulation (PWM) control method can be used for the output power control. The proposed half-bridge inverter should keep unity output displacement factor under the load-impedance varying conditions, if a new PWM control scheme based on the resonant frequency tracking algorithm is adopted. In this paper, electrical characteristics, and losses analysis of the proposed half-bridge resonant inverter are described. Simulation and experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge resonant inverter are presented and discussed.

  • PDF

Suppression of Parallel Plate Modes Using Edge-Located EBG Structure in High-Speed Power Bus

  • Cho, Jonghyun;Kim, Myunghoi
    • Journal of information and communication convergence engineering
    • /
    • 제14권4호
    • /
    • pp.252-257
    • /
    • 2016
  • An edge-located electromagnetic bandgap (EL-EBG) structure using a defected ground structure (DGS) is proposed to suppress resonant modes induced by edge excitation in a two-dimensional planar parallel plate waveguide (PPW). The proposed EL-DGS-EBG PPW significantly mitigates multiple transverse-magnetic (TM) modes in a wideband frequency range corresponding to an EBG stopband. To verify the wideband suppression, test vehicles of a conventional PPW, a PPW with a mushroom-type EBG structure, and an EL-DGS-EBG PPW are fabricated using a commercial process involving printed circuit boards (PCBs). Measurements of the input impedances show that multiple resonant modes of the previous PPWs are significantly excited through an input port located at a PPW edge. In contrast, resonant modes in the EL-DGS-EBG PPW are substantially suppressed over the frequency range of 0.5 GHz to 2 GHz. In addition, we have experimentally demonstrated that the EL-DGS-EBG PPW reduces the radiated emission from -24 dB to -44 dB as compared to the conventional PPW.

다중공진회로를 이용한 고효율 DC-DC 컨버터 (High-Efficiency DC-DC Converter using the Multi-Resonant-Circuit)

  • 정강률
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.218-228
    • /
    • 2021
  • 본 논문에서는 다중공진회로를 이용한 고효율 DC-DC 컨버터를 제안한다. 제안한 컨버터는 하프브리지 전력구조이며 컨버터의 고효율화를 위해 2개의 인덕터(LL)와 1개의 커패시터(C)로 구성된 다중공진회로를 이용한다. 이 다중공진회로는 동작모드에 따라, 각각의 공진주파수를 가진 직렬회로 형태의 공진회로를 각각 형성한다. 본 논문에서는 먼저, 동작모드와 정상상태 기본파 근사 모델링에 의해 제안한 컨버터의 동작원리를 설명한다. 그다음 이에 근거하여 제안한 컨버터의 설계예시를 보인다. 그리고 설계된 회로 파라미터에 의해 제작된 프로토타입 컨버터의 실험결과를 통하여 제안한 컨버터의 고효율 DC-DC 전력변환 동작특성을 입증한다.

음향공명기가 장착된 가스터빈 연소실의 음향장 해석 (Numerical Analysis of Acoustic Behavior in Gas Turbine Combustor with Acoustic Resonator)

  • 박이선;손채훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1110-1115
    • /
    • 2004
  • Acoustic behavior in gas turbine combustor with acoustic resonator is investigated numerically by adopting linear acoustic analysis. Helmholtz-type resonator is employed as acoustic resonator to suppress acoustic instability passively. The tuning frequency of acoustic resonator is adjusted by varying its length. Through harmonic analysis, acoustic-pressure responses of chamber to acoustic excitation are obtained and the resonant acoustic modes are identified. Acoustic damping effect of acoustic resonator is quantified by damping factor. As the tuning frequency of acoustic resonator approaches the target frequency of the resonant mode to be suppressed, mode split from the original resonant mode to lower and upper modes appears and thereby complex patterns of acoustic responses show up. Considering mode split and damping effect as a function of tuning frequency, it is desirable to make acoustic resonator tuned to broad-band frequencies near the maximum frequency of those of the possible upper modes.

  • PDF