• Title/Summary/Keyword: Resonance tube

Search Result 151, Processing Time 0.023 seconds

Acoustic resonance by length of acoustic baffle at Finned Tube bank (핀-튜브군에서 배플 길이에 따른 음향공진)

  • 방경보;류제욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF

Evaluation of Elastic Properties of Anisotropic Cylindrical Tubes Using an Ultrasonic Resonance Scattering Spectroscopy

  • Kim, Jin-Yeon;Li, Zheng
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.6
    • /
    • pp.548-557
    • /
    • 2010
  • An ultrasonic resonance scattering spectroscopy technique is developed and applied for reconstructing elastic constants of a transversely isotropic cylindrical component. Immersion ultrasonic measurements are performed on tube samples made from a boron/aluminum composite material to obtain resonance frequencies and dispersion curves of different guided wave modes propagating in the tube. Theoretical analysis on the acoustic resonance scattering from a transversely isotropic cylindrical tube is also performed, from which complete backscattering and resonance scattering spectra and theoretical dispersion curves are calculated. A sensitive change of the dispersion curves to the elastic properties of the composite tube is observed for both normal and oblique incidences; this is exploited for a systematic evaluation of damage and elastic constants of the composite tube samples. The elastic constants of two boron/aluminum composite tube samples manufactured under different conditions are reconstructed through an optimization procedure in which the residual between the experimental and theoretical phase velocities (dispersion curves) is minimized.

A Case Study on the vibration and noise by acoustic resonance in the tube bank of a boiler of 75MW power plant (75MW 급 발전용 보일러 관군에서의 음향공진에 의한 진동/소음 사례연구)

  • Kim, Cheol-Hong;Bang, Kyung-Bo;Ju, Young-Ho;Byun, Hyung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.150-155
    • /
    • 2000
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a power plant. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At the resonance, the value of vibration in this system was 595 ${\mu}m$, p-p and the sound pressure level was maximum 103 dBA. And the resonance frequency was found to be 35 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance is possible. In this system, the difference of these frequencies was 1.8%. We can evaluate the possibility of acoustic resonance by using damping parameter. We did eliminate acoustic resonance by installing baffle in tube bank. After installing baffle, the level of vibration and noise was reduced dramatically.

  • PDF

Acoustic effects of the sound tube and resonance cavity in Korean Brahman Bells (한국범종의 음관과 명동)

  • 이병호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.1-10
    • /
    • 1983
  • The presence of the sound tube and resonance cavity is unique in Korea Brahman Bells which is no examples in other country bells in the world. The sound tube erected in the crown is effective to emit the fundamental tone of the bell when the condition of resonant transmissibility is satisfied. The results of our analysis shows that the optimum length of the sound tube in the Bell Emile is 96cm but is not the present length, 77cm. The resonance cavity erected underneath the lip of the Bell Emile is found to be for the resonance of standing waves in the space including both bell cavity and resonance cavity and resonance cavity to the fundamental tone of the bell itself, in order that the strongest vibration can last long by least energy and lengthen the reverberation of the bell. Some historical remarks are also made on the magic flute, MANPASIKJUK, which was in existence in Shilla that can lull all evil waves, such as plagues, storms, droughts, famines and even enemies. The sound tube erected in the crown of the bell was originated in this magic flute. Finally, a strong proposal is advanced on the new national symbol of Korean traditional cultural assets. Indeed, it should be highly recommended that the Great King's Bell Emile would be the only real symbol of our national cultural assets by its own right of excellency and richness in every aspect of arts and sciences.

  • PDF

FEM acoustic modal analysis due to location of acoustic baffles to avoid acoustic resonance in the tube bank of boiler for power plant (보일러 튜브군의 음향공진 회피를 위한 음향배플의 위치에 따른 FEM 음향모드해석)

  • Ahn, Sung-Jong;Ju, Young-Ho;Kim, Cheol-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.150-154
    • /
    • 2012
  • A flow induced mechanical vibration and acoustic resonance should be considered at design stage because they are mainly occurred in the tube bank of boiler. Acoustic resonance is occurred when the vortex shedding frequency of tube bank coincides with the acoustic natural frequency of the cavity. Effective solution to avoid acoustic resonance is installing acoustic baffles in the tube banks parallelly inside of the flow cavity. Thus, location and number of acoustic baffles should be exactly calculated to eliminate the acoustic resonance. This paper presents case study of acoustic resonance due to inappropriate number and location of acoustic baffles. Measured frequency and mode in the study is verified by FEM acoustic modal analysis. The number and location of acoustic baffles to avoid acoustic resonance are calculated by using FEM acoustic modal analysis.

  • PDF

Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant (대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진)

  • Bang, Kyung-Bo;Kim, Cheol-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/4 wave (1/4파장 열음향 냉동기의 공명관 길이 의존 특성 연구)

  • Song, Kyu-Joe;Park, Jong-Ho;Koh, Deuk-Yong;Park, Seong-Je
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.229-234
    • /
    • 2001
  • The thermoacoustic refrigerator bas not only considerable possibility but also commercial usability, because it bas high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying length of the resonance tube to 400mm, 500mm, 600mm, 700mm. In order to determine the optimum resonance tube length and the frequency, the $\lambda/4$ thermoacoustic engine and the similar apparatus of Wheatly type refrigerator were constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $56.3^{\circ}C$ at 626Hz in 400mm tube with 40mm stack.

  • PDF

Numerical analysis on the pressure pulsation in the resonance tube (Resonance tube 내 압력 맥동 해석)

  • 곽승철;류호선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.608-614
    • /
    • 1997
  • 2차원 압축성 오일러 방정식을 지배 방정식으로 하여 음향학적 문제를 직접 수치 계산하였다. Roe의 개략적인 리만해(Approximate Riemann Solver)에 의거하여 대류항을 구성하였고 높은 정확도를 유지하기 위해 Vanleer의 MUSCL 방법을 사용하여 공간을 이산화하였다. 시간 적분으로는 2차의 Runge-Kutta 방법을 사용하였다. Resonance tube 내의 음향학적 문제 해석을 위해 최근까지 제시된 음향 경계 조건들을 비교하였고 각 경계 조건들이 갖는 물리적 의미를 고찰하였다. 이들을 통하여 압력파의 물리적인 행태를 모사하였고 실험과 비교하였다. 계산결과들을 통하여 사용된 방법은 전형적인 압축성 유동 해석 문제 뿐만 아니라 선형, 비선형의 음향학적 문제들을 적절한 경계 조건과 결합하여 해석할 수 있음을 알 수 있었고 resonance tube와 같은 공학적으로 실제적인 문제들에 대한 응용이 기대된다.

  • PDF

A Case Study on The Reduction and Examination for Noise and Vibration of Backpass Heat Surface in the Power Plant Boiler (발전용 보일러의 후부 전열면 소음진동 저감에 관한 사례 연구)

  • Lee, Gyoung-Soon;Lee, Tae-Hoon;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.642-647
    • /
    • 2008
  • The boiler structure is determined by combustion characteristics and construction costs in the combustion chamber of a large commercial boiler. The heat transfer in boiler is composed of the radiation and the convection. The convective heat transfer has happened to back-pass heating surface. The combustion gas sequentially passes through the reheater tube, 1st economizer tube, and 2nd economizer tube. In case of being lowered in boiler height, we have to install additional tube bundle in back-pass heating surface for increasing the heat transfer of boiler, which causes the noise and vibration from combustion gas. When the combustion gas passes through the back-pass tube bundle in specified load of commercial boiler, this paper analyzes the acoustic characteristics between vortex-shedding frequency and natural frequency in tube bundle cavity. The case study reduce the resonance by changing natural frequency characteristics of tube-bundle cavity using a way to install ant-noise baffle in the direction of combustion gas flow.

  • PDF

An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/2 wave (1/2파장 열음향 냉동기의 공명관 길이 의존 특성 연구)

  • Song, Kyu-Joe;Park, Jong-Ho;Koh, Deuk-Yong;Kim, Hyo-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.217-222
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying the length of Resonant Tube to 400mm $\sim850mm$. In order to determine the optimum position of stack in the resonance tube and the frequency, the simple $\lambda/2$ thermoacoustic refrigerator was constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $52.6^{\circ}C$ at 827Hz in 400mm tube with 40mm stack.

  • PDF