• 제목/요약/키워드: Resonance state

검색결과 684건 처리시간 0.031초

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

두개강 공명의 영상해부학적 고찰 (The imaging Anatomical Consideration of the Resonance of the Cranial Cavity)

  • 이동명
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.29-37
    • /
    • 2000
  • Because vocal technique is the basis of singing a song beautifully, so this study was undertaken to use the scientific and correct technique in order to get much better musical expressions. Shimadzu X - ray remote control TV system was used for checking the supporting state of diaphragmatic respiration after 5, 10, 15, 20, 25 and 30 sec during phonation in the state of full inhalation between professional singer and non - professional singer. Shimadzu Magnet $nex-{\alpha}$(SMT -50CX/H) was used for examining the scattering state from the resonance of nasal cavity to that of cranial cavity on the basis of diaphragmatic respiration. The results obtained were summerized as follows : 1. The resonance of cranial cavity must be scattered by the energy of diaphragmatic respiration after gathering the foci of the fundamental 5 vowels. 2. while raising the epiglottis, the resonance of nasal cavity must be clearly in order to maintain the resonance of cranial cavity beautifully. 3. We can get musical expressions by maintaining the elasticity of diaphragmatic respiration.

  • PDF

Optimal Basis Functions for Siegert Resonance State Representation in Al2 Electronic Predissociation

  • Jang, Hyo Weon
    • 대한화학회지
    • /
    • 제57권2호
    • /
    • pp.172-175
    • /
    • 2013
  • We compare the relative usefulness of common basis functions and numerical integration methods in representing complex resonance state encountered in the molecular scattering problem of aluminum dimer electronic predissociation. Specifically, the basis set size and computing CPU times are monitored in order to find the minimum requirement for ensuring the modest accuracy of calculated resonance energies (0.1 $cm^{-1}$) for more than 100 resonance states. The combination of the so-called one-dimensional box eigenfunctions and energy-dependent boundary functions are found to be most efficient if integration is done using the basis set quadrature rules.

레이저 관성항법장치에서 링레이저 자이로 디더 운동에 의한 가속도계 공진이 자체 정렬/항법 성능에 미치는 영향 분석 (Self-Alignment/Navigation Performance Analysis in the Accelerometer Resonance State Generated by Dither Motion of Ring Laser Gyroscope in Laser Inertial Navigation System)

  • 김천중;임경아;김선아
    • 한국군사과학기술학회지
    • /
    • 제24권6호
    • /
    • pp.577-590
    • /
    • 2021
  • In this paper, we theoretically analyzed the self-alignment/navigation performance in the accelerometer resonance state generated by dither motion of ring laser gyroscope in LINS and verified it through simulation. As a result of analysis, it is confirmed that the amplitude of the accelerometer measurement amplified in the accelerometer resonance state is decreased in the process of sampling per the navigation calculation period and that frequency is changed by the aliasing effect too. It was also analysed that the attitude error in self-alignment is determined by the amplitude/frequency of the accelerometer measurement, the gain of the self-alignment loop, and the velocity and position error in the navigation is determined by the amplitude/frequency/phase error of the accelerometer measurement. This analysis and simulation results show that the self-alignment and navigation performance is not be degraded only when the amplification factor of the accelerometer measurement in the accelerometer resonance state is 3 or less

Solid State Dynamic Nuclear Polarization of 1H Nuclear Spins at 0.3 T and 4.2 K

  • Shim, Jeong Hyun
    • 한국자기공명학회논문지
    • /
    • 제21권4호
    • /
    • pp.114-118
    • /
    • 2017
  • Here, I report solid state Dynamic Nuclear Polarization (DNP) of $^1H$ nuclear spins at 0.3 T and 4.2 K. The DNP polarizer was developed based on a commercial X-band Electron Spin Resonance (ESR) modified for DNP, in combination with a NMR console and a liquid-Helium cryostat. By detuning magnetic field, DNP spectrum was measured to find the optimal condition. At +3 mT detuned from on-resonance field, $^1H$ NMR signal of 60:40 glycerol/water frozen solution doped with 20 mM perdeuterated-Tempone was amplified 43 times. The $^1H$ spin polarization obtained at 4.2 K is over 3100 times higher than that at 300 K. The width of the DNP spectrum, which is five times broader than ESR spectrum, is inconsistent with solid effect or thermal mixing, and presumably suggests a different DNP mechanism.

Steady-State Analysis of Reactance Oscillators having Multiple Oscillations

  • Matsuo, K.;Matsuda, T.;Nishio, Y.;Yamagami, Y.;Ushida, A.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.203-206
    • /
    • 2000
  • In this paper, we discuss an efficient steady-state analysis of reactance oscillators having multiple oscillations. Our oscillator is consisted of the Cauer or Foster reactance sub-circuit and a negative resistor such as tunnel diode. The reactance circuit has many resonance and antiresonance points on the frequency response curve. Such a circuit having the specified resonance and anti-resonance points can be easily synthesized with the fundamental circuit theory. In this case, the multiple oscillations may occur near at the anti-resonance points. We have developed a user friendly simulator for getting the exact steady state responses using the SPICE.

  • PDF

Structural Studies of Hydrotalcite Compounds Calcined with Different Temperatures by $^{27}Al$ Solid-state NMR Spectroscopy

  • Park, Tae-Joon;Kim, Yong-Ae
    • 한국자기공명학회논문지
    • /
    • 제11권1호
    • /
    • pp.42-47
    • /
    • 2007
  • Several hydrotalcite compounds calcined with different temperature for applications in a chlorine resistant textile were prepared, and its structural changes in dependence on the temperature were studied by using $^{27}Al$ solid-state nuclear magnetic resonance(NMR) spectroscopy. We found that the Al coordination was partly lowered from octahedral to tetrahedral site as the calcined temperature goes up. And we also investigated the hydrotalcite-treated textile for chlorine resistance by using $^{27}Al$ solid-state NMR spectroscopy.

  • PDF