• Title/Summary/Keyword: Resonance phenomena

Search Result 183, Processing Time 0.028 seconds

Sommerfeld Phenomena of an Asymmetric Rotor (축비대칭 회전계에서 나타나는 Sommerfeld 현상)

  • Shin, Eung-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.56-63
    • /
    • 2014
  • This paper provides a comprehensive study on the Sommerfeld phenomena in an asymmetric rotor with a nonideal power supply. An analytical approach is employed by deriving the equations of motion in a nondimensional form. The system parameters, including the asymmetry, external and internal damping, and motor power, are chosen to find their effects on the characteristics of the Sommerfeld phenomena and critical behavior around resonance. Results show that the rotor asymmetry suppresses the Sommerfeld phenomena and helps pass through resonance if the asymmetry is small. However, it is observed that the opposite effects exist in case of a large asymmetry. It is also found that the effects of external damping on the Sommerfeld phenomena are similar to those of the asymmetry, whereas internal damping has less effects than external damping and the asymmetry. By performing numerical simulations, four types of critical behavior are identified from the viewpoints of the stability and the passage through resonance.

A Study on Frequency-Modulated Methods for Reducing Acoustic Resonance in HID Lamp (고압방전램프의 음향공명감소를 위한 주파수변조에 관한 연구)

  • Kim, Gi-Jung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.622-626
    • /
    • 2001
  • HID(high intensity discharge)lamps are high pressure mercury lamp, high pressure sodium lamp and metalhalide lamp. metalhalide lamp among these lamps has considered to be one of the most effective artificial light sources and this lamp has good efficiency, good color rendition and good focusing capability, But the shortcorning of metalhalide lamp is known as acoustic resonance phenomena in the discharge tube when lighted by electronic ballast and then acoustic resonance cause various problems such as the arc instability, light output fluctuations. In this paper, to reduce the acoustic resonence phenomena, the electronic ballast was designed by three methods for high frequency operation wish frequency-modulated sinusodial waves in acoustic resonance frequency band. These frequency-modulated methods are resonance frequency and resonance frequency, resonance frequency and non-resonance frequency non-resonance frequency and non-resonance frequency Experiment results could't show the Presence of acoustic resonance visually and it proved that the resonance-generating conditions can be avoided by continuously changing the two operating frequencies in acoustic resonance band (20.59kHz∼94.2kHz).

  • PDF

Reduction of Acoustic Resonance Phenomena in Pulse Start MetalHalide Lamp (MH200W) (고효율 펄스스타트 메탈핼라이드램프(MH200W)의 음향공명현상감소)

  • 김기정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.8-14
    • /
    • 2001
  • MetalHalid lamps have good efficiency, good color rendition and good focusing capability. But the shortcoming of metalhalid lamps is blown as acoustic resonance phenomena in the arc tube. Such acoustic resonance produce annoying fluctuations in the intensity and distribution of the emitted light, they can raise the voltage to the point where the arc is extinguished and they can move the arc close enough to the wall to cause local overheating and tube cracking. The objective of this research is to reduce acoustic resonance in the arc tube of the Pulse Start MetaIHaide lamp(MH200[W]). To reduce the acoustic resonance phenomena the electronic ballast was designed for high frequency operation with the constant frequency sinusoidal wave of 89[kHz] in the 84.6[kHz]∼94.2[kHz] range. Experimental results show that the acoustic resonance phenomena are not in the arc tube of Pulse Start MetalHalide lamp (MH200[W]) .

  • PDF

Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant (대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진)

  • Bang, Kyung-Bo;Kim, Cheol-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

THE COMPLEX PERMEABILITY AND MATCHING FREQUENCY OF FERRITE MICROWAVE ABSORBER

  • Shin, Jae-Young;Oh, Jae-Hee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.800-804
    • /
    • 1995
  • The complex permeability dispersions and the microwave absorbing phenomena are investigated in ferrite microwave absorber. The complex permeability of NiZn ferrite, NiZnCo ferrite, and Y-type hexagonal ferrite were measured in 200MHz-14GHz range. Two types of resonances, the domain wall and the spin rotational resonance, were observed. With a ferrite particle with a diameter of about $1\;\mu\textrm{m}$, only spin rotational resonance were observed. The theoretical matching frequency is determined by plotting the measured complex permeability locus on the impedance matching solution map. One or two impedance matching phenomena are observed in the ferrite absorbers according to their complex permeability loci on the impedance matching solution map. The first matching frequency, found in the ferrite-rubber composites, which was higher than that of spin rotational resonance, increased with spin rotational resonance frequency.

  • PDF

A study on the reduction of noise and vibration by acoustic resonance in the tube bank of a circulating fluidized bed combustion boiler (순환 유동층 보일러 관군의 음향공진에 의한 이상소음 발생 및 저감 연구)

  • Park, Eung-Kyu;Song, Keun-Bok;Kim, Won-Hyun;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.101-106
    • /
    • 2011
  • In the present paper, the phenomena of abnormal noise and vibration due to acoustic resonance of CFBC(Circulating Fluidized Bed Combustion) boiler was presented. The acoustic resonance which occurred in the gas path of CFBC boiler system was caused by coincidence of vortex shedding frequency of tube bank and acoustic natural frequency of duct and hopper. And, the phenomena of beating arose from the interference of two closed resonant waves at 66.4Hz and 70.8Hz. There are two control methods for acoustic resonance in this system. The first method is to change the vortex shedding frequency from the structural alterations on the tube bank. And the second method is to change the acoustic natural frequency of the gas path with the installation of anti-noise baffles. The second one which is relatively easy to apply, was adapted in this study. As a result, the noise and vibration level have been decreased by 41dB and 94% at 66.4Hz, respectively. And the improvement of noise and vibration at 70.8Hz was identified by sensory evaluation.

  • PDF

Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering (대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

Dark Resonance and Its Potential Applications: High-Resolution Spectroscopy

  • Ham, Byoung-Seung
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.110-116
    • /
    • 2001
  • Recently observed dark resonance phenomena is solids are reviewed and discussed for potential applications to high-resolution coherence spectroscopy. in an inhomogeneously broadened system, a new type of high-resolution spectroscopy based on electromagnetically induced transparency is demonstrated.

Acoustic resonance by length of acoustic baffle at Finned Tube bank (핀-튜브군에서 배플 길이에 따른 음향공진)

  • 방경보;류제욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF