• 제목/요약/키워드: Resonance condition

검색결과 625건 처리시간 0.034초

Severe bony ankylosis of the temporomandibular joint on one side and contralateral adhesion: A case report

  • Song, Ji-Young;Kim, Seong-Gon;Choi, Hang-Moon;Kim, Hyun Jung
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.103-108
    • /
    • 2015
  • Bony fusion between the mandibular condyle and skull base involves temporomandibular joint (TMJ) bony ankylosis. This condition might originate from trauma, infection, or systemic disease. TMJ adhesion can develop after synovial damage. Both TMJ ankylosis and adhesion lead to functional impairment and pain. Here, we present a case of a 50-year-old female who had bony ankylosis of the right TMJ and adhesion of the left TMJ. She had otitis media in the right ear. A large mass in the right TMJ was observed on computed tomograph. Magnetic resonance image showed a large fused bone mass with normal bone marrow in the right TMJ and flattening of the condyle with a thin disk in the left TMJ. Gap arthroplasty with temporal fascia was performed on the right TMJ, and discectomy, high condylectomy, and coronoidectomy were performed on the left TMJ. During a 2-year follow-up after surgery, the patient had no recurrence.

전동 지게차용 3 상 유도 모터의 소음 진동 특성에 대한 연구 (A Study on the Characteristic of Noise and Vibration in 3-Phase Induction Motor for the Forklift)

  • 김우형;정진태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.764-769
    • /
    • 2007
  • This paper is studied the noise and vibration characteristics analysis of the three-phase induction AC motor of the electrical forklift. And we suggest the method which the reduction orders the noise and vibration to be the mechanical. In other to investigate these characteristics, we considered the mechanical characteristics, the electromagnetic effects, and these interactions. In mechanical, we studied the characteristic of the stator, the bearing supported condition of the rotor, and the sound radiation. In electronically, this paper is considered the harmonic effect which is related the magnetic motive force (mmf) with respect to the characteristic of the slot number of the rotor and the stator and the pole number of the motor. Finally we investigated the overall noise and vibration of the induction motor by relations between the electronically harmonic and the mechanical resonance of the stator. By the analysis of the generally three-phase induction motor, we suggest the design methodology to low noise and vibration.

  • PDF

중대형 굴삭기 유압시스템의 압력 맥동 저감 연구 (A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-large Excavator)

  • 김영현;주원호
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.18-23
    • /
    • 2011
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.

이동질량에 의한 보의 횡진동저감을 위한 모델링 및 압전작동기를 이용한 최적제어 (Modeling and Optimal Control with Piezoceramic Actuators for Transverse Vibration Reduction of Beam under a Traveling Mass)

  • 성윤경;류봉조
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.126-132
    • /
    • 1999
  • The paper presents the modeling and optimal control for the reduction of transverse vibration of simply supported beam under a moving mass. The equations of motion are derived by using assumed mode method. The coriolis and centripetal accelerations are accommodated in the equations of motion to account for the dynamic effect of the traveling mass. In order to reduce the transverse vibration of the beam, an optimal controller with full state feedback is designed based on the linearized equations of motion. The optimal actuator locations are determined with the evaluation of an optimal cost functional defined by the worst initial condition with the trade-off of controlled mode performance. Numerical simulations are performed with respect to various velocities and different traveling masses. Even if the velocity of the traveling mass reaches to the critical speed which can cause the resonance of the beam, the controller with two piezoelectric actuators shows the excellent performance under severe time-varying disturbances of the system.

  • PDF

감속단 백래시 기여율 변화에 따른 2단 기어 감속서보 시스템의 주파수 응답 특성 (Frequency Response Characteristics of Two-Staged Gear Reduction Servo System According to the Backlash Contribution Ratio Variation of Each Gear Reduction Stage)

  • 백주현;홍성민;양태석;김수현;곽윤근
    • 한국정밀공학회지
    • /
    • 제19권5호
    • /
    • pp.103-109
    • /
    • 2002
  • The paper investigates the change of frequency response characteristics on two-stage gear reduction servo system according to the variation of backlash amount of each gear reduction stage, under the condition that the backlash of total system is constant. It is shown that the frequency response characteristics of the system heavily depend on the contribution ratio which is defined as a ratio of the first backlash amount to the total backlash. It is also found that there is an optimal backlash combination to maximize the bandwidth of two-stage gear reduction servo system when the allowable total backlash is determined.

Delayed Dural Arteriovenous Fistula after Microvascular Decompression for Hemifacial Spasm

  • Kim, Sung Han;Chang, Won Seok;Jung, Hyun Ho;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권2호
    • /
    • pp.168-170
    • /
    • 2014
  • Dural arteriovenous fistula (AVF) is very rare, acquired lesion that may present with intracranial hemorrhage or neurological deficits. The etiology is not completely understood but dural AVF often has been associated with thrombosis of the involved dural sinuses. To our knowledge, this is the first well documented intracranial hemorrhage case caused by dural AVF following microvascular decompression for hemifacial spasm. A 49-year-old male patient had left microvascular decompression of anterior inferior cerebellar artery via retrosigmoid suboccipital craniotomy. The patient was in good condition without any residual spasm or surgery-related complications. However, after 10 months, he suffered sudden onset of amnesia and dysarthria. Computed tomography and magnetic resonance imaging revealed the presence of dural AVF around the left transverse-sigmoid sinus. The dural AVF was treated with Onyx$^{(R)}$ (ev3) embolization. At the one-year follow up visit, there were no evidence of recurrence and morbidity related to dural AVF and its treatment. This case confirms that the acquired etiology of dural AVF may be associated with retrosigmoid suboccipital craniotomy for hemifacial spasm, even though it is an extremely consequence of this procedure.

압전층의 2단 증착법을 이용한 체적 음향파 박막형 공진기의 제작과 성능향상에 관한 연구 (A Study of the Fabrication and Enhancement of Film Bulk Acoustic Wave Resonator using Two-Step Deposition Method of Piezoelectric Layer)

  • 박성현;추순남;이능헌
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권7호
    • /
    • pp.308-314
    • /
    • 2005
  • The 2 GHz film bulk acoustic wave resonator(FBAR), one of the most necessary device of the next generation mobile communication system, consisted of solidly mounted resonator(SMR) structure using Brags reflector, was researched in this paper The FBAR applied SiO$_{2}$ and W had large difference of the acoustic impedance to reflector Al to electrode and ZnO to piezoelectric layer. Specially, the FBAR applied the two-step deposition method to improve the c-axis orientation and increase reproducibility of the fabrication device had good performance. The electrical properties of plasma such as impedance, resistance, reactance, $V_{pp},\;I{pp}$, VSWR and phase difference of voltage and current, was analyzed and measured by RF sensor with the variable experiment process factors such as gas ratio, RF power and base vacuum level about concerning the thickness, c-axis orientation, adhesion and roughness. The FBAR device about the optimum condition resulted reflection loss(S$_{11}$) of -17 dB, resonance frequency of 1.93 GHz, electric-mechanical coefficient(k$_{eff}$) of 2.38 $\%$ and Qualify factor of 580. It was seen better qualify than the common dielectric filter at present and expected on business to the filter device of 2 GHz bandwidth with the MMIC technology.

Digital Control Methods of Two-Stage Electronic Ballast for Metal Halide Lamps with a ZVS-QSW Converter

  • Wang, Yijie;Zhang, Xiangjun;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.451-460
    • /
    • 2010
  • This paper presents a new kind of digital control metal halide lamp electronic ballast. A zero-voltage-switch quasi-square-wave (ZVS-QSW) dual Buck converter is adopted here. In this paper, a digital control method is proposed to achieve ZVS for the converter. This ZVS can be realized during the whole working condition. Single-cycle-peak-current control is proposed to solve the problem of excessive inductor current during a low-frequency reversal transient. Power loop control is also realized and its consistency for different lamps is good. An AVR special microcontroller for a HID ballast is used to raise the control performance, and the low-frequency square-wave control method is adopted to avoid acoustic resonance. A 70W prototype was built in the laboratory. Experimental results show that the electronic ballast works reliably. Furthermore, the efficiency of the ballast can be higher than 92%.

VCM(voice coil motor)를 이용한 3차원 나노 형상 측정 시스템 (3-D Nano Topology Measurement using VCM)

  • 정종규;염우섭;박기환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1439-1443
    • /
    • 2007
  • In this paper, vibration reduction techniques of a voice coil motor (VCM) actuator are presented for AFM imaging system. The damping coefficient of the actuator driven by VCM with a flexure hinge is quite low and it cause the about 30dB peak amplitude response at the resonance frequency. To decrease this peak response, we design and apply elliptical band-stop filters to xy and z axis VCM actuator. Frequency response of each actuator with filter is measured to verify the effect of the filters. As a sensor, capacitive sensor is used. Vibration reduction rate of the xy actuator with the filter is also measured while real AFM scanning condition. As another method, closed loop control with the capacitive sensor is applied to the xy axis actuator to add an electrical damping effect and vibration reduction rate measured. These vibration reduction rates with each method are compared. In the case of z axis actuator, the frequency response of force (gap) control loop is measured. For comparison, the frequency response using a conventional PID controller is also obtained. Finally, the AFM image of a standard grid sample is measured with the designed controller to analyze the effect in the AFM imaging.

  • PDF

정적 하중하의 굽힘 압전 복합재료 작동기의 작동 성능 (Actuating Performance of a Bending Piezoelectric Composite Actuator with a Thin Sandwiched PZT Plate under Static Loads)

  • 우성충;박기훈;구남서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1231-1236
    • /
    • 2007
  • This study presents the static and dynamic actuating performances of a bending piezoelectric actuator with a thin sandwiched PZT plate under a static load. The stored elastic energy within the actuators which occurs during a curing process is obtained through a flexural bending test. An actuating performance is evaluated in terms of an actuating displacement at the simply supported condition. The results reveal that an actuator that consists of a top layer having a high elastic modulus and a low coefficient of thermal expansion exhibits a better performance than the rest of actuators due to the formation of the large stored elastic energy within the actuator system. When actuators are excited at the alternating current voltage, the effect of PZT ceramic softening results in a slight reduction in the resonance frequency of each actuator as the applied electric field increases. It is thus suggested that the static and dynamic actuating characteristics of bending piezoelectric actuators with a thin sandwiched PZT plate should be simultaneously considered in controlling their performances.

  • PDF