• 제목/요약/키워드: Resonance condition

검색결과 628건 처리시간 0.028초

검증된 고속철도 차량의 20량편성 정밀모형에 의한 철도교량의 동적응답 분석 (Verified 20-car Model of High-speed Train for Dynamic Response Analysis of Railway Bridges)

  • 김상효;김병석;허진영;최성락
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.485-492
    • /
    • 2001
  • The dynamic analysis model is developed with the high-speed train (KTX) and a 2-span continuous prestressed concrete box girder bridge with a double track. The analytical results are compared with the dynamic field test results and found to be valid to yield quite accurate dynamic responses. The various trainset models with different number of cars are developed and compared with the results of the regular 20-car trainset model. It is concluded that the reduced trainset models, such as 7-car and 10-car models, cannot exactly produce the dynamic responses of bridges, especially when the train speed is high. Under the coincidence condition of two trains traveling with resonance velocity in the opposite directions, it is found that the impact factor under two-way coincidence is three times larger than that under one-way traffic. Consequently, for the bridge with a double-track it is necessary to check not only the dynamic responses of the bridge with one-way traffic but those with two-way coincidence.

  • PDF

Cervicothoracic Spinal Epidural Hematoma after Anterior Cervical Spinal Surgery

  • Lee, Dong-Yeob;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권6호
    • /
    • pp.541-543
    • /
    • 2010
  • The purpose of this case report is to describe a rare case of a cervicothoracic spinal epidural hematoma (SEH) after anterior cervical spine surgery. A 60-year-old man complained of severe neck and arm pain 4 hours after anterior cervical discectomy and fusion at the C5-6 level. Magnetic resonance imaging revealed a postoperative SEH extending from C1 to T4. Direct hemostasis and drainage of loculated hematoma at the C5-6 level completely improved the patient's condition. When a patient complains of severe neck and/or arm pain after anterior cervical spinal surgery, though rare, the possibility of a postoperative SEH extending to non-decompressed, adjacent levels should be considered as with our case.

Dynamic Lumbar Spinal Stenosis : The Usefulness of Axial Loaded MRI in Preoperative Evaluation

  • Choi, Kyung-Chul;Kim, Jin-Sung;Jung, Byung-Joo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.265-268
    • /
    • 2009
  • Two cases of dynamic lumbar spinal stenosis were identified by the authors using axial loaded magnetic resonance image (MRI). In both cases, the patients presented with neurogenic claudication but MRI in decumbency showed no definite pathologic condition associated with their symptoms. In contrast, axial loaded MRI demonstrated constrictive spinal stenosis and a significantly decreased dural sac caused by epidural fat buckling and thickening of the ligamentum flavum in both cases. In the second case, a more prominent disc protrusion was also demonstrated compared with decumbent MRI. After decompressive surgery, both patients had satisfactory outcomes. Axial loaded MRI can therefore give decisive information in dynamic spinal disorders by allowing simulation of an upright position.

성인의 원위 경비골 관절에 발생한 골연골종 - 1예 보고 - (Osteochondroma on distal tibiofibular joint in adult - One Case Report -)

  • 이준영;이광철
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.269-273
    • /
    • 2003
  • Although osteochondromas are common lesions, osteochondroma accompanying diastasis of the ankle joint in a child or adult is an uncommon condition. No previous cases of distal tibiofibular diastasis caused by an osteochondroma in adult have been reported except in child. The authurs experienced a case of mild distal tibiofibular diastasis secondary to an osteochondroma in a 37-year-old female presented with right ankle pain. Osteochondroma of the distal tibiofibular joint were detected on magnetic resonance imaging (MRI). She was pain-free 4 weeks after excision of the osteochondroma. The patient has remained asymptomatic for 1 years postoperatively. Early excision obviates the need for complex reconstructive surgery to correct ankle deformity later.

  • PDF

An Enhanced Skirt Characteristics Triple-Mode Filter

  • Lee, Ja-Hyeon;Nam, Hun;Lim, Yeong-Seog
    • Journal of electromagnetic engineering and science
    • /
    • 제12권3호
    • /
    • pp.210-215
    • /
    • 2012
  • This paper presents a compact microstrip triple-mode filter with enhanced skirt characteristics. The presented triple-mode filter configuration supports three transmission poles and three transmission zeros within the nearby passband. Two of transmission zeros are generated by a triple-mode resonator itself, and the third one is generated by small cross-couplings between the I/O ports. Each resonance condition and the transmission zero generation conditions are analyzed using an equivalent circuit. The bandpass filter is designed for a 2.4 GHz WLAN. The filter was fabricated with a relative dielectic constant of 3.5 and a thickness of 0.76 mm. The fabricated filter has a small size ($7.9mm{\times}7.2mm$, i.e., $0.107{\lambda}_g{\times}0.098{\lambda}_g$, where ${\lambda}_g$ is guided wavelength at a center frequency) and shows high performing skirt characteristics.

호흡기 질환에서 단순흉부 X-선 진단 (Plain Chest X-ray Diagnosis of Respiratory Disease)

  • 김상진
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권4호
    • /
    • pp.353-356
    • /
    • 1993
  • Advent of new imaging modalities such as computed tomography, magnetic resonance imaging and ultrasound contributed greately to the specific imaging diagnosis. However plain chest X-ray is still most prequently used for imaging diagnosis of respiratory disease in clinical pratic and it is important to make a good quality of X-ray film and good interpretation. The optimal chest X-ray should be taken with full inspiration without rotation and motion and the exposure is at the level of barely demonstrable thoracic vertebral disc space. It is recommended that higk KVP technique for detection of lesions which is overlaped by mediastinum, heart and rib cage. It is better to examine chest X-ray film start at some distance(6-8 feet) and closer to the film later on and the reader should not read a film in fatigue condition. The reading room should be quiet and relately dark illumination. It is important, to make a good X-ray film and good interpretation to reduce the observer error.

  • PDF

LCC 공진형 컨버터를 적용한 산업용 전원장치 응용연구 (The Design and Applications of LCC Resonant Converter)

  • 안석호;장성록;류홍제
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.566-572
    • /
    • 2015
  • This study introduces an LCC resonant converter operating on a continuous conduction mode. The LCC resonant converter has the advantage of improving system efficiency, especially under the rated load condition, because it can reduce conduction loss by improving the resonance current shape and switching loss by increasing the lossless snubber capacitance. The proposed LCC resonant converter is applied to various applications, including a 60 kW EV fast charger, a 24 kJ/s high-voltage capacitor charger, and a 20 kV, 20 kW high-precision DC power supply. Experimental results prove that the proposed LCC resonant converter topology can be effectively used as a converter topology for these applications.

주파수 영역 Green 함수와 모멘트법을 이용한 유전체 평판 부착 다이폴 안테나의 특성해석 (Analysis of a Dipole Antenna Attached on a Dielectric Slab Using a Spectral-Domain Green's Function and the Method of Moments)

  • 오이석
    • 한국통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.2703-2709
    • /
    • 1996
  • This paper proposes an exact numerical method for analyzing a dipole antenna attached on a dielectric slab. A Green's function for an infinitesimal current filament on a dielectric slab is derived and a field integral equation is formulated using a boundary condition. The moment Method is used to solve the field integral equation to otain current distribution on the antenna. Since an asymptotic function is used to compute the impedance matrix elements, the computataion time is significantly reduced. Using the computed current distributions, the input impedances, the resonance lengths and the resonant resistances of the antennas for various values of the thichnessandthe dielectric constant of the slab are obtained. It was found that the resonant length and the resonant resistance are decrease monotonically as the dielectric constant increases, however, those are changed up-and-down as the substrate thickness increases.

  • PDF

민감도와 역 관계를 이용한 전기기기의 입력 전류 분포 최적화 (Source Current Optimization of Electromagnetic Devices using Sensitivity and Inverse Relation)

  • 이주현;변진규;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.211-213
    • /
    • 1999
  • This paper describes a new method for source current optimization of the electromagnetic devices. In a conventional method of current distribution optimization using design sensitivity based on a finite element method, position and width of coils are generally optimized under condition that shape of those is given. they cannot find the global minimum because the number of coils is pre-determined. To avoid this local minimum, source current region which is discretized uniformly is considered as design parameter. This discretized regions have zero or one current value during the optimization process. The proposed method is applied to magnetic resonance imaging(MRI) magnet.

  • PDF

박용디젤기관의 착화실패가 추진축계종진동에 미치는 영향에 관한 이론적 연구 (A theoretical investigation of mis-firing effects on the crankshaft axial vibration of diesel engine)

  • 변창주;김의간;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.28-36
    • /
    • 1988
  • Since the oil shocks of 1970s, the quality of the fuel oil for marine diesel engines has become more degarded than ever. When the poorer quality fuel is burned, carbon residues of the fuel oil cause blockage of the fuel injection valve nozzle and troubles of fuel injection system. The mis-firing of engine occurs due to the decrease of fuel quantity injected, the decrease of compression pressure in the slow speed range, the increase of fuel leaked and the high ignition temperature of degraded fuel etc. This paper is to investigate theoretically the effects of mis-firing on the crankshaft axial vibration of diesel engine. The cylinder pressure in operation is calculated by the computer aided simulation of closed cycle for a large two-stroke diesel engine and also the exciting force of axial vibration and the resonance amplitudes are calculated. And then, the condition of normal state, misfiring and one-cylinder cut-off operation are analyzed. The results of calculations show good agreements with those of the actual measurements.

  • PDF