• Title/Summary/Keyword: Resonance condition

Search Result 625, Processing Time 0.025 seconds

A Study on Design Criteria of Piping System in Petrochemical Plant (석유화학 플랜트의 배관계 설계기준에 대한 연구)

  • Min, Sun-Kuo;Choi, Myung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.192-199
    • /
    • 2002
  • Largely, there are three kinds of the design criteria of piping system in petrochemical plant. The first is on the pipe thickness in accordance with the design pressure of piping system. The second is on the static state evaluation by thermal growth and the other is on the dynamic evaluation by piping vibration. According to the ASME B31.3 code, the internal pressure design thickness fur straight pipe shall be calculated as a code formula. And the static design by thermal displacement is defined 7000 cycles of fatigue life in operating the piping system with a design condition. However, the dynamic design evaluation in comparative with small displacements of high frequencies to the static condition has not established clearly the method, yet. So, this study purposes to present the trial of a proposal of dynamic design criterion on the basis of static design method.

Investigation of Hydrodynamic Mass Characteristic for Flow Mixing Header Assembly in SMART (SMART 유동혼합헤더집합체의 동수력 질량 특성 고찰)

  • Lee, Gyu Mahn;Ahn, Kwanghyun;Lee, Kang-Heon;Lee, Jae Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.30-36
    • /
    • 2020
  • In SMART, the flow mixing header assembly (FMHA) is used to mix the coolant flowing into the reactor core to maintain a uniform temperature. The FMHA is designed to have enough stiffness so the resonance with reactor internal structures does not occurs during the pipe break and the seismic accidents. Since the gap between the FMHA and the core support barrel assembly is very narrow compared with the diameter of FMHA, the hydrodynamic mass effect acting on the FMHA is not negligible. Therefore the hydrodynamic mass characteristics on the FMHA are investigated to consider the fluid and structure interaction effects. The result of modal analysis for the dry and underwater conditions, the natural frequency of primary vibration mode for the horizontal direction is reduced from 136.67 Hz to 43.76 Hz. Also the result of frequency response spectrum seismic analysis for the dry and underwater conditions, the maximum equivalent stress are increased from 13.89 MPa to 40.23 MPa. Therefore, reactor internal structures located in underwater condition shall consider carefully the hydrodynamic mass effects even though they have sufficient stiffness required for performing its functions under the dry condition.

Microstructure and Electrical Properties of ZnO Thin Film for FBAR with Annealing Temperature (FBAR용 ZnO 박막의 열처리 온도변화에 따른 미세조직 및 전기적 특성)

  • Kim, Bong-Seok;Kang, Young-Hun;Cho, Yu-Hyuk;Kim, Eung-Kwon;Lee, Jong-Joo;Kim, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.1 s.284
    • /
    • pp.42-47
    • /
    • 2006
  • In this paper, we prepared high-quality ZnO thin films for application of FBAR (Film Bulk Acoustic Resonator) by using pulse DC magnetron sputtering. To prevent the formation of low dielectric layers between metal and piezoelectric layer, Ru film of 30 nm thickness was used as a buffer layer. In addition we investigated the influence of annealing condition with various temperatures. As the annealing temperature increased, the crystalline orientation with the preference of (002) c-axis and resistance properties improved. The single resonator which was fabricated at $500^{\circ}C$ exhibited the resonance frequency and the return loss 0.99 GHz and 15 dB, respectively. This work demonstrates potential feasibility for the use of thin film Ru buffer layers and the optimization of annealing condition.

Static and Dynamic Behavior of Tunable DFB Laser based on Modal Transmission-Line Theory (전송선로 이론에 기초한 파장 변환 DFB 레이저의 정적 및 동적 작용)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.147-152
    • /
    • 2014
  • A longitudinal modal transmission-line theory(L-MTLT) to analyze the static and dynamic behavior of two-section distributed feedback (DFB) lasers is used. The characteristic impedance and equivalent propagation constant of DFB structure with active layer are derived from L-MTLT. A two-section DFB laser is analogous to a transmission-line network, in which each section is described by transmission-line block corresponding to the equivalent factors. The longitudinal resonant condition of DFB laser based on equivalent transmission-line network is used to reformulate the rate equations so that static and dynamic behavior of two-section DFB lasers with active layer is demonstrated and analyzed accurately.

Electromagnetic Fields in General Hospital (의료기관 내 전자파 환경)

  • Shin, Sei-One;Yun, Sang-Mo;Shin, Hyoun-Jin;Ahn, Hyun-Soo;Ahn, Hee-Deok
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.167-176
    • /
    • 2004
  • Background: Electromagnetic fields (EMF) are ubiquitous in modern society including medical field. As the technology of medical instruments and telecommunications has developed rapidly, it has influenced on our lives in many ways. Modern medical practice requires high quality medical equipments, which have a great deal of electromagnetic interference and susceptibility. The purpose of this study were to evaluate electromagnetic condition under usual clinical condition and to suggest a practical guideline in general hospital. Materials and Methods: The actual state of the electromagnetic interference in the medical field was studied under usual clinical conditions including operating rooms, intensive care units, magnetic resonance imaging unit, and hyperthermia unit. Results: There was considerable noise as a result of electromagnetic fields from medical equipments including electrosurgical units and hyperthermia unit, and cellular phones, which could induce serious functional derangements of functioning medical devices. Conclusion: It will be necessary to evaluate the individual electromagnetic situations under various medical conditions and to define a limited zone for cellular phone as well as reposition medical equipments to secure a safer medical practice and to minimize electromagnetic interference.

  • PDF

A Fuzzy Expert System Based on Hybrid Database for Fault Diagnosis of Industrial Turbomachinery (산업용 터보기기 결함 진단을 위한 복합적 데이터베이스 구조의 퍼지 전문가 시스템)

  • 백두진;김승종;김창호;장건희;이용복
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.703-712
    • /
    • 2003
  • This paper suggests a fuzzy expert system for fault diagnosis of rotating machinery, based on modulated databases. In the proposed system, alarm and trip levels are set based on ISO, considering operating condition, machinery type and maintenance history. Input signals for diagnosis, such as sub-and super-harmonic components of vibration and mean value, are normalized from 0 to 1 under the threshold level and otherwise equal to one so that chronic faults slightly below the threshold level can be monitored. The database for diagnosis consists of two modules: the well-known Sohre's chart module and if-then type rules. The Sohre's chart is utilized for the most common problems of high-speed turbomachinery, while the rule-based module, which was collected from many papers and reports, is for diagnosing peculiar faults according to the type of machinery. To infer the results from two modules, a fuzzy operation of Yager sum was adopted. Using a simulator constructed in laboratory, experimental verification was performed for the cases of unbalance and resonance which were intended. The experimental results show that the proposed fuzzy expert system has feasibility in practical diagnosis of rotating machinery.

A Hybrid Fuzzy Expert System Based on Module-type Database for Fault Diagnosis of Turbomachinery (모듈 구조 데이터베이스 기반의 터보기기 결함 진단용 하이브리드 퍼지 전문가 시스템)

  • 백두진;김승종;김창호;곽현덕;장건희;이용복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.303-312
    • /
    • 2003
  • This paper suggests a fuzzy expert system for fault diagnosis of rotating machinery, based on modulated databases. In the proposed system, alarm and trip levels are set based on ISO, considering operating condition, machinery type and maintenance history. Input signals for diagnosis, such as sub- and super-harmonic components of vibration and mean value, are normalized from 0 to 1 under the threshold level and otherwise equal to one so that chronic faults slightly below the threshold level can be monitored. The database for diagnosis consists of two modules: the well-known Sohre's chart module and if-then type rules. The Sohre's chart is utilized for the most common problems of high-speed turbomachinery, while the rule-based module, which was collected from many papers and reports, is for diagnosing peculiar faults according to the type of machinery. To infer the results from two modules, a fuzzy operation of Yager sum was adopted. Using a simulator constructed in laboratory, experimental verification was performed for the cases of resonance and housing looseness which were intended. The experimental results show that the proposed fuzzy expert system has feasibility in practical diagnosis of rotating machinery.

  • PDF

Mouth opening limitation caused by coronoid hyperplasia: a report of four cases

  • Kim, Sung-Min;Lee, Jin-Hyeok;Kim, Hak-Jin;Huh, Jong-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.301-307
    • /
    • 2014
  • Coronoid process hyperplasia is a rare condition that causes mouth opening limitation, otherwise known as trismus. The elongated coronoid processes impinge on the medial surfaces of the zygomatic arches when opening the mouth, which limits movement of the mandible and leads to trismus. Patients with trismus due to coronoid process hyperplasia do not have any definite symptoms such as temporomandibular joint pain or sounds upon clinical examination, and no significant abnormal signs are observed on panoramic radiographs or magnetic resonance images of the temporomandibular joint. Thus, the diagnosis of trismus is usually very difficult. However, computed tomography can help with the diagnosis, and the condition can be treated by surgery and postoperative physical therapy. This paper describes four cases of patients who visited our clinic for trismus and were subsequently diagnosed with coronoid process hyperplasia. Three were successfully treated with a coronoidectomy and postoperative physical therapy.

Micro structural characteristics of Bragg reflector of SMR type FBAR device deposited by RF magnetron sputtering (RF 마그네트론 스퍼터링에 의해 증착된 SMR 구조 FBAR 소자의 Bragg 반사층의 미세구조 특성에 관한 연구)

  • Park, Sung-Hyun;Lee, Sun-Beom;Lee, Neung-Heon;Shin, Young-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1992-1994
    • /
    • 2005
  • In this study, Bragg reflector was formed as tungsten(W) and $SiO_2$ deposited by RF magnetron sputtering according to variable conditions of RF power and working pressure to apply to the SMR type FBAR device, one of the next generation mobile communication devices. The micro-structural properties such as a crystal orientation, roughness and micro- structure were measured by XRD, AFM and SEM and the best condition of Bragg reflector was elicited with analyzing that results of the thin films about each conditions. Finally, FBAR device was fabricated with applying the Bragg reflector was formed on the best condition and measured the resonance properties and compared other research and considered it.

  • PDF

High Pressure Synthesis and Physical Properties of the Solid Solution, $SrLaAl_{1-x}Ni_xO_4(0

  • 변송호
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.11
    • /
    • pp.1084-1088
    • /
    • 1995
  • A complete solid solution (SrLaAl1-xNixO4) between insulating SrLaAlO4 and metallic SrLaNi(Ⅲ)O4 oxides were prepared under high oxygen pressure (1.5 kbar, 800 ℃). They have tetragonal K2NiF4-type structure in all the solid solution range. Compared with lattice parameters of the same solid solution prepared under normal condition (1 bar, 1200 ℃), large decrease in the c-parameter was induced by high pressure treatment while no noticeable variation of the a-parameter was observed. Although marked changes of structural parameters, magnetic susceptibilities, and electron paramagnetic resonance spectra were consistently occurred before and after x=0.5, overall behaviors were essentially the same with those of solid solution prepared under normal condition. Such a phenomenon is explained by assuming the formation of partially filled narrow σ*x2-y2 band for x>0.5. Lattice contraction along the c-axis by high pressure treatment seems not to broaden this band. Particularly, the continuous absorption characteristic of a high free carrier concentration for x>0.5 and the absence of Ni-O in-plane stretching mode in the infrared absorption spectra supports this picture. However, the conductivities increasing with temperature for all solid solution suggest that some localization character, of probably Anderson type, remains for x>0.5.