• 제목/요약/키워드: Resonance Type

검색결과 1,085건 처리시간 0.029초

Effective ketogenic diet in CACNA1A-related 'epilepsy of infancy with migrating focal seizures'

  • Na, Hyejin;Lee, Sanghoon;Kim, Young Ok
    • Journal of Genetic Medicine
    • /
    • 제18권2호
    • /
    • pp.137-141
    • /
    • 2021
  • Genetic causes of developmental and epileptic encephalopathy (DEE) have been rapidly uncovered from mid-2010s. The mutations of gene enconding calcium channel, voltage-dependent, P/Q type, alpha 1A subunit (CACNA1A) are recently detected in DEE, which gene is already known well in familial hemiplegic migrine type 1 or episodic ataxia type 2. Ketogenic diet therapy (KDT) is effective in some DEE, which data is short in CACNA1A encephalopathy. A 3-month-old male with global developmental delay and multidrug-resistant focal seizures was diagnosed as epilepsy of infancy with migrating focal seizures (EIMFS). Brain magnetic resonance imaging and metabolic screening were all normal. Whole exome sequencing revealed two variants of CACNA1A: c.899A>C, and c.2808del that is from his mother. His seizures disappeared within 3 days whenever on KDT, which recurred without it. To our knowledge, this rare case of EIMFS with novel mutations of CACNA1A, is the first report in CACNA1A encephalopathy becoming seizure-free on KDT.

신경섬유종증 1형 환자에서 드물게 발생하는 심장 신경섬유종: 영상의학적 소견 (A Rare Case of Cardiac Neurofibroma in a Patient with Neurofibromatosis Type 1: Radiologic Findings)

  • 서상현;노지영
    • 대한영상의학회지
    • /
    • 제82권5호
    • /
    • pp.1321-1327
    • /
    • 2021
  • 신경섬유종증 1형은 비교적 흔한 유전 질환이며 신경섬유종 형성, 피부의 색소 이상, 홍채의 리쉬결절 및 골격 이상들을 특징으로 한다. 다발성 피부 신경섬유종은 양성 신경초 종양이며 신경섬유종증 1형의 특징적인 병변이다. 신경섬유종증 1형과 관련된 심장 신경섬유종은 매우 드물며 문헌에 몇 가지 사례가 보고되었다. 이에 저자들은 신경섬유종증 1형을 가진 32세 여성에서 수술로 확진된 좌심실 신경섬유종의 컴퓨터단층촬영 및 자기공명영상 소견을 보고한다.

Minimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears

  • Lee, Hyun Il;Ryu, Ho Young;Shim, Sang-Jun;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • 제18권4호
    • /
    • pp.197-205
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double-row suture-bridge configuration ($2{\times}2$ anchor with $4{\times}4$ suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using $2{\times}2$ anchor double-row configuration. The mean age was 61.3 years (range, 31-81 years). Two double-loaded suture anchors were used for medial-row. Four medial-row stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using pre- and postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears.

벤더형 모듈을 이용한 광대역 압전 하베스터 연구 (Study of Broadband Piezoelectric Harvester using the Bender-Type Module)

  • 김창일;권태형;여서영;윤지선;정영훈;홍연우;조정호;백종후
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.112-117
    • /
    • 2018
  • In this study, a bender-type piezoelectric energy harvester was fabricated and evaluated to compensate for the disadvantages of high-power generation only in the resonance frequency range of a piezoelectric harvester using a piezoelectric cantilever. The generated power was investigated according to various changes in the vibration environment. Compared with the piezoelectric cantilever module, the bender-type piezoelectric module showed a larger number of peak voltages. The primary peak voltage shifted toward the low frequency when the spring was coupled to the bender-type piezoelectric module. The harvester of the three bender-type modules had a vibration frequency exceeding 1 mW in the 34-45 Hz range and generated 3.112 mW of power at the vibration frequency of 38 Hz. The harvester of the six bender-type modules had a vibration frequency exceeding 1 mW in the 31-45 Hz range and generated 3.081 mW of power at the vibration frequency of 35 Hz.

Imaging Patterns of Bacillus Calmette-Guérin-Related Granulomatous Prostatitis Based on Multiparametric MRI

  • Seungsoo Lee;Young Taik Oh;Hye Min Kim;Dae Chul Jung;Hyesuk Hong
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.60-67
    • /
    • 2022
  • Objective: To categorize multiparametric MRI features of Bacillus Calmette-Guérin (BCG)-related granulomatous prostatitis (GP) and discover potential manifestations for its differential diagnosis from prostate cancer. Materials and Methods: The cases of BCG-related GP in 24 male (mean age ± standard deviation, 66.0 ± 9.4 years; range, 50-88 years) pathologically confirmed between January 2011 and April 2019 were retrospectively reviewed. All patients underwent intravesical BCG therapy followed by a MRI scan. Additional follow-up MRI scans, including diffusion-weighted imaging (DWI), were performed in 19 patients. The BCG-related GP cases were categorized into three: A, B, or C. The lesions with diffusion restriction and homogeneous enhancement were classified as type A. The lesions with diffusion restriction and a poorly enhancing component were classified as type B. A low signal intensity on high b-value DWI (b = 1000 s/mm2) was considered characteristic of type C. Two radiologists independently interpreted the MRI scans before making a consensus about the types. Results: The median lesion size was 22 mm with the interquartile range (IQR) of 18-26 mm as measured using the initial MRI scans. The lesion types were A, B, and C in 7, 15, and 2 patients, respectively. Cohen's kappa value for the inter-reader agreement for the interpretation of the lesion types was 0.837. On the last follow-up MRI scans of 19 patients, the size decreased (median, 5.8 mm; IQR, 3.4-8.5 mm), and the type changed from A or B to C in 11 patients. The lesions resolved in four patients. In five patients who underwent prostatectomy, caseous necrosis on histopathology matched with the non-enhancing components of type B lesions and the entire type C lesions. Conclusion: BCG-related GP demonstrated three imaging patterns on multiparametric MRI. Contrast-enhanced T1-weighted imaging and DWI may play a role in its differential diagnosis from prostate cancer.

요요 진동시스템을 이용한 가동물체형 파력 발전 시스템의 기계-전기 통합해석 모델링 및 성능 해석 (Electro-Mechanical Modeling and Performance Analysis of Floating Wave Energy Converters Utilizing Yo-Yo Vibrating System)

  • 심규호;박지수;장선준
    • 대한기계학회논문집A
    • /
    • 제39권1호
    • /
    • pp.79-87
    • /
    • 2015
  • 요요 진동시스템을 이용한 파력발전 장치의 모델링 및 성능해석을 수행하였다. 본 연구의 파력발전 시스템은 기계적 요소인 요요진동 시스템, 모션정류 시스템, 동력전달 시스템과 전기적 요소인 발전시스템으로 구성된다. 특히 요요 진동시스템을 적용하여 파랑의 입력을 회전운동으로 변환하였으며 입력되는 파랑의 크기가 공진현상에 의해 증폭되어 높은 에너지 변환효율을 갖도록 구성되었다. 기계적 시스템과 전기적 시스템의 임피던스 연결(Impedance matching)을 통해 기계-전기 통합 해석 모델을 수립하였다. 일정 입력 가속도 0.14g 에서 다양한 파랑 주파수와 시스템 감쇠비에 대한 수치적 성능 해석을 진행하였다. 최대 전기적 출력은 공진주파수에서 부하저항이 최적 부하 조건을 만족할 때 발생하였으며, 이때 최대 전기 출력은 290W, 발전 효율은 48%이다. 해석 결과를 통해 공진 현상을 이용하여 파력발전장치의 출력을 크게 증가시킬 수 있음을 확인하였다.

자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰 (In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • 전자공학회논문지SC
    • /
    • 제40권3호
    • /
    • pp.172-180
    • /
    • 2003
  • 본 연구에서는 자기공명영상(MRI)에서 수소 원자핵의 공명주파수(PRF) 방법을 기반으로 인체 종아리 근육 외부의 열원에 의해 근육 내부로 열원이 전달되는 과정을 비침습적으로 관찰하는 방법을 제시한다. 열전달과정을 온도 변화로 측정하였는데 온도 영상의 안정성 및 보정 실험은 phantom을 이용하였고 온도의 변화는 phantom과 인체 모두에서 측정하였다. Phantom 실험은 agarose gel을 중탕하여 약 50℃까지 가열시킨 후 1시간의 냉각과정 동안 매 3분마다 데이터를 획득하였다. 인체 실험에서는 지원자의 종아리(the calf)에 hot pack을 이용하여 열을 전달하였다. Hot pack을 발열시키기 전에 기준 데이터를 1번 획득하고, 발열시킨 후부터 매 2분마다 30분 동안 데이터를 획득하였다. 획득된 영상 데이터는 위상차 영상으로 재구성된 다음 각 ROI에서의 평균 위상차를 관측하였다. 온도를 34.2∼50.2℃의 범위에서 변화시켰을 때 phantom의 위상차는 온도 변화에 대해 선형적으로 변하였다. 이 범위에서 측정된 온도의 해상도는 0.0457 radian/℃(0.0038 ppm/℃)였다. 인체 실험에서는 각 영상에서 hot pack과 가까운 위치의 평균 위상차가 hot pack과 먼 위치의 평균 위상차보다 작은 값을 나타냈다 이를 통해 같은 영상 단면에서도 열원(heat source)과의 거리에 따라서 온도 변화가 다르게 나타나는 것을 관찰할 수 있었다. 본 연구를 통해 PRF방법을 이용하여 MRI에서도 비침습적으로 인체 내부의 열전달과정을 관측하였고 이로서 온열치료 시 MRI가 임상적 이용 가능성이 있음을 확인하였다.

두개강내 고형성 종양의 H-1 자기공명분광법 (In Vivo H-1 MR Spectroscopy of Intracranial solid Tumors)

  • 성수옥;장기현;한문희;연경모;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.86-93
    • /
    • 1997
  • 목적: 두개강내 고형성 종야에서 병리조직학적 진단과 악성도에 따라 특징적 H-1자기공명분광(MRS) 양상이 나타나는지를 알아보고자 하였다. 대상 및 방법: 고형성 뇌종양 환자 81명(저등급 교종 17예, 고등ㅇ급 교종 31예, 림프종 9예, 뇌수막종 8예, 신경세포종 4예, 수아세포종 3예, 원시성신경외배엽종 3예, 전이암 2예, 기타 4예)을 대상으로 생체내 MRS를 시행하여 스펙트럼을 분석하였다. MRS는 1.5T 장치를 사용하여 PRESS기법으로 TR/TE 2000/270msec, VOI $2{\times}2{\times}2cm^3$로 얻었다. 대사 산물의 공명(resonance) 분석은 N-acetyl aspartate(NAA)/Creatine complix(Cr)비, Choline complex(Cho)/Cr비, Lactate(Lac)/Cr비를 구하였으며, 기타 산물에 대하여는 기존의 문헌에 기초하여 존재 유무를 분석하였다. 결과: 모든 고형성 뇌종양에서 NAA는 감소하고, Cho과 lactate는 증가하였다. Cr은 증가하거나 감소하는 등 다양한 결과를 보였다. 모든 종야에서 NAA/Cr이 감소한 반면, Cho/Cr과 Lac/Cr은 증가하였다. 고등급 교종에서는 평균 Cho/Cr과 lactate/Cr이 각각 저등급 교종에 비해 모두 유의하게 높았다(Cho/Cr ; $2.4{\pm}0.7{\;}vs.{\;}1.7{\pm}0.8,{\;}P<0.05,{\;}lactate/Cr{\;};{\;}1.3{\pm}1.9{\;}vs.{\;}0.4{\pm}0.6$, P<0.05). 그러나 NAA/Cr은 유의한 차이가 없었다. 뇌수막종과 신경세포종, 수아세포종에서 Cho/Cr이 고등급 교종의 수준 이상으로 높았다. 결론: H-1 MRS는 고형성 뇌종에서 저등급과 고등급 교종의 감별에 유용하게 이용될 수 있으나, 교종이외의 고형성 양성종양에서도 고등급 교종과 같은 양상을 보이므로 한게가 있다고 생각된다.

  • PDF

정상 위 조직과 위암 조직의 시험관 내 수소자기공명분광 (Ex Vivo ${1}^H$ MR Spectroscopy: Normal gastric and cancer tissue)

  • 조지연;신운재;최기승;김수현;은충기;양영일;이정희;문치웅
    • Journal of Gastric Cancer
    • /
    • 제3권3호
    • /
    • pp.151-157
    • /
    • 2003
  • Purpose: In this study, we attempted to ascertain the proton magnetic resonance spectroscopy (${1}^H$ MRS) peak characteristics of human gastric tissue layers and finally to use the metabolic peaks of MRS to distinguish between normal and abnormal gastric specimens. Materials and Methods: Ex-vivo ${1}^H$ MRS examinations of thirty-five gastric specimens were performed to distinguish abnormal gastric tissues invaded by carcinoma cells from normal stomach-wall tissues. High-resolution 400-MHz (9.4-T) ${1}^H$ nuclear magnetic resonance (NMR) spectra of two gastric layers, a proper muscle layer, and a composite mucosasubmucosa layer were compared with those of clinical 64- MHz (1.5-T) MR spectra. Three-dimensional spoiled gradient recalled (SPGR) images were used to determine the size and the position of a voxel for MRS data collection. Results: For normal gastric tissue layers, the metabolite peaks of 400-MHz ${1}^H$ MRS were primarily found to be as follows: lipids at 0.9 ppm and 1.3 ppm; alanine at 1.58 ppm; N-acetyl neuraminic acid (sialic acid) at 2.03 ppm; and glutathione at 2.25 ppm in common. The broad and featureless featureless spectral peaks of the 64-MHz MRS were bunched near 0.9, 1.3, and 2.0, and 2.2 ppm in human specimens without respect to layers. In a specimen (Borrmmann type III) with a tubular adenocarcinoma, the resonance peaks were measured at 1.26, 1.36 and 3.22 ppm. All the peak intensities of the spectrum of the normal gastric tissue were reduced, but for gastric tumor tissue layers, the lactate peak split into 1.26 and 1.39 ppm, and the peak intensity of choline at 3.21 ppm was increased. Conclusion: We found that decreasing lipids, an increasing lactate peak that split into two peaks, 1.26 ppm and 1.36 ppm, and an increasing choline peak at 3.22 ppm were markers of tumor invasion into the gastric tissue layers. This study implies that MR spectroscopy can be a useful diagnostic tool for gastric cancer.

  • PDF

유전체 다중층을 이용한 국소 표면 플라즈몬 공명 센서의 감도 향상에 관한 연구 (Estimation of Sensitivity Enhancements on Localized Surface Plasmon Resonance Sensor Using Dielectric Multilayer)

  • 안희상;강태영;오진우;김규정
    • 한국광학회지
    • /
    • 제28권1호
    • /
    • pp.28-32
    • /
    • 2017
  • 본 논문에서는 LSPR 센서에 적용하기 위한 제한된 높이 100 nm에서 $TiO_2$, $SiO_2$의 다중층을 이용한 LSPR 센서를 디자인을 제안했다. LSPR 센서의 구조는 유전체 층과 나노 구조가 있는 금속층으로 디자인 하였다. 금속층은 금 박막 40 nm와 높이 40 nm, 주기 600 nm, 선폭 300 nm인 나노와이어 구조체를 올려놓은 구조로 디자인하였다. 유전체 층의 높이를 100nm로 제한하고, $TiO_2$, $SiO_2$가 반복되는 구조로 하여 반복층의 개수를 1~4개로 변경하면서 비교 분석하였다. 파장 가변형 SPR을 디자인하기 위해 각도를 75도로 고정하고 파장을 변화시켜 FEM방식으로 계산하였다. 결과로 굴절율이 고정되어 있을 때 다중층의 개수가 증가할수록 공명 파장이 짧아지는 현상을 확인 하였고, 파장의 변화에 더 민감하게 변화하는 것을 측정하였다. 다만, 다중층의 개수가 3개층 이상이 되면 변화하지 않는 것을 확인하였다.