• Title/Summary/Keyword: Resonance Type

검색결과 1,085건 처리시간 0.026초

상용해석 툴을 이용한 소형 스크류 디캔터의 설계에 관한 연구 (A Study on Design of Small Type Screw Decanter using Commercial Analysis Tool)

  • 김용석;김종태;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.46-52
    • /
    • 2014
  • This study suggests a small-sized screw decanter specialized for dredging sites. Generally, conventional screw decanters are composed of a cylinder and a cone. However, the suggested screw decanter simply has a cone based on a cone-type bowl structure. In this research, a commercial analysis tool is used to establish an optimal design for the bowl and the screw conveyor. Moreover, the base frame, where the main bearings that support the spindle of the bowl and the screw conveyor are installed, is optimally designed considering the weight of the rotating body and the deflection caused by the high centrifugal force. Furthermore, the natural frequency range of the spinning body, the bowl and the screw conveyor, is applied to this base frame; it is designed not to correspond to the resonance frequency range and achieves stability as a result. This study suggests an optimal design for the rotating body and the base frame of a screw decanter considering its vibration characteristics. Such a design will prevent overuse of materials and help to reduce the weight and volume-and the price-of a screw decanter.

TMD 설치에 따른 돔 형상 대공간 구조물의 지진응답분석 (Seismic Response Analysis of Dome-Shaped Large Spatial Structures According to TMD Installation)

  • 구승연;유상호;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제23권4호
    • /
    • pp.27-34
    • /
    • 2023
  • In this study, the seismic response characteristics of the three analysis model with or without TMD were investigated to find out the effective dome shape. The three analysis models are rib type, lattice type and geodesic type dome structure composed of space frame. The maximum vertical and horizontal displacements were evaluated at 1/4 point of the span by applying the resonance harmonic load and historical earthquake loads (El Centro, Kobe, Northridge earthquakes). The study of the effective TMD installation position for the dome structure shows that seismic response control was effective when eight TMDs were installed in all types of analysis model. The investigation of the efficiency of TMD according to dome shape presents that lattice dome and geodesic dome show excellent control performance, while rib dome shows different control performance depending on the historical seismic loads. Therefore, lattice and geodesic types are desirable for seismic response reduction using TMD compared to rib type.

몰드형 건식 계기용 변압기 진동 특성 분석 (Analysis of Vibration Characteristics for a Molded Dry-type Potential Transformer)

  • 김무선;장동욱;김승모
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.209-214
    • /
    • 2017
  • 현재 철도 차량에 쓰이고 있는 대부분의 계기용 변압기는 장치 내부에 절연유가 충진되어 있는 유입식 계기용 변압기 방식으로서, 내구 연한 도래와 더불어 차량 운행 중 내부 압력 상승에 의해 폭발의 위험성이 있다. 이에 대한 해결책으로 절연 수지를 사용하여 방압 기능이 탁월한 몰드형 건식 계기용 변압기 개발이 필요하다. 이에 제품의 국산화가 가능하도록 한국철도기술연구원에서는 몰드형 건식 계기용 변압기를 개발 진행 중에 있다. 그 연구의 일환으로 개발 제품의 진동 특성 분석과 함께, 진동 환경하에서 변압기의 성능 유지 여부를 확인하여야 한다. 이번 연구에서는 철도 차량 부품의 진동 시험 방법 규격인 KS R 9144 및 IEC 61373 에 따라서 개발 제품의 공진시험과 모의 장기 수명 시험을 진행하였다. 고유 진동수는 해석을 통한 모달 분석과 공진 시험을 병행하여 결과를 비교 분석하였으며 규격 조건을 만족함을 확인하였다. 또한 모의 장기 수명 시험 후 성능 시험을 통해 오랜 시간 진동 환경 하에서도 개발 변압기의 기능에 문제가 없음을 확인하였다.

자기공진방식 무선전력전송 등가회로 추출 및 특성 분석 (Performance Analysis and Equivalent Circuit Extraction for Magnetic Resonance Type Wireless Power Transfer)

  • 박대길;김영현;구경헌
    • 한국항행학회논문지
    • /
    • 제21권4호
    • /
    • pp.371-376
    • /
    • 2017
  • 본 논문에서는 6.78 MHz 에서 공진하는 대형 코일을 이용한 자기공진방식 무선전력전송 시나리오를 제시하고 3차원 전자계 시뮬레이션, 자기공진방식 무선전력전송 등가회로를 통한 특성을 비교하였다. 본 논문에서 제시한 자기공진방식의 무선전력전송 등가회로는 기존 등가회로에 추가적으로 코일 간에 발생하는 기생 커패시턴스를 고려하였다. 이를 바탕으로 제작한 자기공진방식 무선전력전송 코일을 측정하고 시뮬레이션 예측과 비교하였다. 비교 결과 전송 특성 및 공진 주파수 천이 정도를 예측할 수 있었다. 제시한 자기공진방식 무선전력전송 등가회로 특성과 측정치의 오차는 ${\Delta}{\mid}S11{\mid}$이 최대 1.31 dB, ${\Delta}{\mid}S21{\mid}$이 최대 1.36 dB로 유사하게 예측하였다.

복합재료의 파손 감지를 위한 동조형 음향방출 신호분석 기법 (Resonance Type Acoustic Emission Signal Analyzing Method for the failure detection of the composite materials)

  • 이창훈;최진호;권진희
    • 한국항공우주학회지
    • /
    • 제32권3호
    • /
    • pp.30-36
    • /
    • 2004
  • 장섬유 복합재료는 항공우주 구조물, 로봇 팔 등의 구조물에 광범위하게 적용되고 있으며, 복합재료의 비파괴 검사방법에 대한 연구는 구조의 안전성과 신뢰성을 향상시키기 위하여 매우 중요한 연구 분야로 대두되고 있다. 본 논문에서는 AE 선호의 특정주파수 성분을 추출할 수 있는 풍조회로를 가진 AE 신호 분석 장비를 설계, 제작하였다. 제작된 AE 신호 분석 장비에 충격이나 기계적 진동 등과 같은 외란을 가하였을 때 제작된 AE 신호 분석 장비의 잡음레벨은 상용 AE 신호 분석 장비의 잡음레벨보다 매우 낮은 값을 나타내었다. 또한 복합재료 시편의 정, 동적 인장시험 하에서 제작된 AE 분석 장비는 상용 장비와 통일한 수준의 복합재료 파손감지능력을 나타냄을 확인할 수 있었다.

Predicting the Frequency of Combustion Instability Using the Measured Reflection Coefficient through Acoustic Excitation

  • Bae, Jinhyun;Yoon, Jisu;Joo, Seongpil;Kim, Jeoungjin;Jeong, Chanyeong;Sohn, Chae Hoon;Borovik, Igor N.;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권4호
    • /
    • pp.797-806
    • /
    • 2017
  • In this study, the reflection coefficient (RC) and the flame transfer function (FTF) were measured by applying acoustic excitation to a duct-type model combustor and were used to predict the frequency of the combustion instability (CI). The RC is a value that varies with the excitation frequency and the geometry of the combustor as well as other factors. Therefore, in this study, an experimentally measured RC was used to improve the accuracy of prediction in the cases of 25% and 75% hydrogen in a mixture of hydrogen and methane as a fuel. When the measured RCs were used, an unstable condition was correctly predicted, which had not been predicted when the RCs had been assumed to be a certain value. The reason why the CI occurred at a specific frequency was also examined by comparing the peak of the FTF with the resonance frequency, which was calculated using Helmholtz's resonator analysis and a resonance frequency equation. As the CI occurred owing to the interaction between the perturbation in the rate of heat release and that in the pressure, the CI was frequent when the peak of the FTF was close to the resonance frequency such that constructive interference could occur.

An Improved Active Damping Method with Capacitor Current Feedback

  • Geng, Yi-Wen;Qi, Ya-Wen;Liu, Hai-Wei;Guo, Fei;Zheng, Peng-Fei;Li, Yong-Gang;Dong, Wen-Ming
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.511-521
    • /
    • 2018
  • Proportional capacitor current feedback active damping (CCFAD) has a limited valid damping region in the discrete time domain as (0, $f_s/6$. However, the resonance frequency ($f_r$) of an LCL-type filter is usually designed to be less than half the sampling frequency ($f_s$) with the symmetry regular sampling method. Therefore, ($f_s/6$, $f_s/2$) becomes an invalid damping region. This paper proposes an improved CCFAD method to extend the valid damping region from (0, $f_s/6$ to (0, $f_s/2$), which covers all of the possible resonance frequencies in the design procedure. The full-valid damping region is obtained and the stability margin of the system is analyzed in the discrete time domain with the Nyquist criterion. Results show that the system can operate stably with the proposed CCFAD method when the resonance frequency is in the region (0, $f_s/2$). The performances at the steady and dynamic state are enhanced by the selected feedback coefficient H and controller gain $K_p$. Finally, the feasibility and effectiveness of the proposed CCFAD method are verified by simulation and experimental results.

A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

  • Kang, In-Ho;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.190-195
    • /
    • 2011
  • PURPOSE. This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS. As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Br${\aa}$nemark System$^{(R)}$ Mk III TiUnite$^{TM}$, Straumann Standard Implant SLA$^{(R)}$, and Astra Tech Microthread$^{TM}$-OsseoSpeed$^{TM}$) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS. In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Br${\aa}$nemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION. The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level.

용량형 격막식 게이지와 공진형 실리콘 게이지의 저진공 특성 (Low vacuum characteristics of the capacitance diaphragm gauges and the resonance silicon gauges)

  • 홍승수;신용현;정광화
    • 한국진공학회지
    • /
    • 제12권3호
    • /
    • pp.151-156
    • /
    • 2003
  • 저진공 국가표준기인 초음파간섭 수은주압력계를 이용하여 두 개의 용량형 격막식 게이지와 두 개의 공진형 실리콘 게이지를 교정하였다. 용량형 격막식 게이지의 센서부는 금속으로 되어 있으므로 견고하고 과압에 잘 견딜 뿐만 아니라 우수한 분해능을 가지고 있으며, 공진형 실리콘 게이지는 우수한 안정성과 기계적인 충격에 강한 특성을 가지고 있다. 이들의 교정 불확도를 국제표준화기구에서 제정한 측정불확도 표현지침서에 따라 분석하여 비교하였으며, 그 결과 확장불확도의 최대 차이는 교정압력 100 Pa에서 $9\times10^{-3}$Pa 이었다. 또한 공진형 실리콘 게이지의 표준압력에 대한 압력비의 차이가 0.5 % 이내이었으므로 저진공 영역의 전달표준기로 사용이 가능함을 알 수 있었다.

Pseudoglandular Formation in Hepatocellular Carcinoma Determines Apparent Diffusion Coefficient in Diffusion-Weighted MRI

  • Park, In Kyung;Yu, Jeong-Sik;Cho, Eun-Suk;Kim, Joo Hee;Chung, Jae-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.79-85
    • /
    • 2018
  • Purpose: To determine the impact of pseudoglandular formation on apparent diffusion coefficient (ADC) values of hepatocellular carcinoma (HCC) in diffusion-weighted imaging (DWI), and to validate the results using histopathological grades. Materials and Methods: We assessed 182 HCCs surgically resected from 169 consecutive patients. Each type of tumor pseudoglandular formation was categorized into "non-," "mixed-," or "pure-," based on official histopathology reports. The ADC for each tumor was independently measured, using the largest region of interest on the ADC map. Data were assessed using the analysis of variance test, with Bonferroni correction for post hoc analysis to stratify the relationship of ADCs with pseudoglandular formation, followed by subgroup analysis according to the histopathological tumor grades. Results: The mean ADC was significantly higher in pure pseudoglandular lesions (n = 5, $1.29{\pm}0.08{\times}10^{-3}mm^2/s$) than in non-pseudoglandular lesions (n = 132, $1.08{\pm}0.17{\times}10^{-3}mm^2/s$; P = 0.003) or mixed-pseudoglandular lesions (n = 45, $1.16{\pm}0.24{\times}10^{-3}mm^2/s$; P = 0.034). The ADC values and pseudoglandular formation were significantly correlated in moderately differentiated HCCs (n = 103; r = 0.307, P = 0.007), while well- (n = 19) and poorly-differentiated HCCs (n = 60) did not show significant correlation (r = 0.105 and 0.068, respectively; P = 0.600 and 0.685, respectively). Conclusion: The degree of pseudoglandular formation could be one of the determinants of ADC in DWI of HCCs-especially moderately differentiated HCCs-while its influence does not appear to be significant in well- or poorly differentiated HCCs.