• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.028 seconds

Design and Comparison of Superconducting Magnets with Circular Coil Elements for Magnetic Resonance Imaging (원형무코일로 구성된 MRI용 초전도 자석의 설계와 비교)

  • Kim, Yong-Gwon;Hyun, Jung-Ho;Seo, Jeung-Hoon;Kim, Hyug-Gi;Oh, Chang-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.57-62
    • /
    • 2011
  • This paper proposed a method which is the three types of magnet model for improving field inhomogeneity of superconducting magnet. The length of coil wire was compared for the optimized current pattern using minimum power methods and field inhomogeneity under the specific simulation condition in case of same magnet field strength about each magnet type field inhomogeneity. Length of wire and field inhomogeneity were compared under the same condition(18 target points, 20cm DSV). According to the simulation results, the smaller target points can reduce the wire length but it can not improve the field inhomogeneity. Length of wire and low field inhomogeneity can not improve in same time. However, small DSV and reducing target points can overcome the these problem. And to conclude, if it processes shimming as reducing target points in case of magnet model which is open to space, about the size of same imaging region it needs a lot of current values(or the length of wire) and decreases field homogeneity but it is useful to get small ROI.

Imaging Anatomy of Waldeyer's Ring and PET/CT and MRI Findings of Oropharyngeal Non-Hodgkin's Lymphoma

  • Zhang, Chun-Xing;Liang, Long;Zhang, Bin;Chen, Wen-Bo;Liu, Hong-Jun;Liu, Chun-Ling;Zhou, Zheng-Gen;Liang, Chang-Hong;Zhang, Shui-Xing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3333-3338
    • /
    • 2015
  • Background: This study was conducted to analyze positron emission tomography (PET) / computed tomography (CT) and magnetic resonance imaging (MRI) performance with oropharyngeal non-Hodgkin's lymphoma (ONHL).Materials and Methods: The complete image data of 30 ONHL cases were analyzed, all patients were performed PET / CT and MRI examination before the treatment, with the time interval of these two inspections not exceeding 14 days. The distribution, morphology, MRI signal characteristics, enhancement feature, standardized uptake value (SUV) max value and lymph node metastasis way of the lesions were analyzed. Results: Among the 30 cases, 23 cases were derived from the B-cell (76.7%), 5 cases were derived from the peripheral T cells (16.7%) and 2 cases were derived from the NK/T cells (6.7%). 19 cases exhibited the palatine tonsil involvement (63.3%). As for the lesion appearance, 10 cases appeared as mass, 8 cases were the diffused type and 12 cases were the mixed type. 25 cases exhibited the SUVmax value of PET / CT primary lesions as 11 or more (83.3%). MRI showed that all patients exhibited various degrees of parapharyngeal side-compressed narrowing, but MRI still exhibited the high-signal fat, and the oropharyngeal mucosa was intact. 25 cases were associated with the neck lymph node metastasis, among who 22 cases had no necrosis in the metastatic lymph nodes, while the rest 3 cases exhibited the central necrosis in the metastatic lymph nodes. Conclusions: PET / CT and MRI have important value in diagnosing and determining the lesion extent of ONHL.

The Relationship between Bone Bruise in MR-Imaging and the Degrees of Acute Anterior Cruciate Ligament Injury (급성 전방십자인대 손상 시 자기공명영상에서 나타나는 골멍과 전방십자인대 손상 정도의 관계)

  • Jeong, Hwa-Jae;Shin, Hun-Kyu;Ko, Chun-Suk;Kim, Jang-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: The aim of this retrospective study was to evaluate the relationship between appearance and size of bone bruise and severity of anterior cruciate ligament (ACL) injury with magnetic resonance imaging (MRI), furthermore, to identify the mechanism of ACL injury by analyzing the footprint of bone bruise. Materials and Methods: Sixty-five subjects who was taken an MRI within 6 weeks after acute ACL injury were studied. All MRI showed ACL injury and associated bone bruises. Bone bruises were analyzed using Costa-Paz classification based on appearance and location and also scored using Kornaat bone bruise grading system based on size and location. The severity of the ACL injury was graded using a 4-point system (ie, grade 0-3) with oblique coronal MRI. Results: There was statistically significant correlation between Costa-Paz classification of bone bruises in lateral femoral condyle and grade of ACL injury. There were more type 2 lesions in partial tear group (grade 1, 2), however, type 3 lesions of Costa-Paz classification in complete tear group (P=0.037). Significant positive correlations were observed between Kornaat total bone bruise score and grade of ACL injury (P=0.014). Most common ACL injury mechanism was pivot shift injury. Other mechanisms were clip valgus injury, phantom foot injury, and hyperextension injury. Conclusion: It is highly suggested that appearance and size of bone bruise is related to severity of ACL injury after acute ACL injury. The foot print of bone bruise provides valuable clues to identify ACL injury mechanism.

  • PDF

Receptor Binding Affinities of Synthetic Cannabinoids Determined by Non-Isotopic Receptor Binding Assay

  • Cha, Hye Jin;Song, Yun Jeong;Lee, Da Eun;Kim, Young-Hoon;Shin, Jisoon;Jang, Choon-Gon;Suh, Soo Kyung;Kim, Sung Jin;Yun, Jaesuk
    • Toxicological Research
    • /
    • v.35 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • A major predictor of the efficacy of natural or synthetic cannabinoids is their binding affinity to the cannabinoid type I receptor ($CB_1$) in the central nervous system, as the main psychological effects of cannabinoids are achieved via binding to this receptor. Conventionally, receptor binding assays have been performed using isotopes, which are inconvenient owing to the effects of radioactivity. In the present study, the binding affinities of five cannabinoids for purified $CB_1$ were measured using a surface plasmon resonance (SPR) technique as a putative non-isotopic receptor binding assay. Results were compared with those of a radio-isotope-labeled receptor binding assay. The representative natural cannabinoid ${\Delta}^9$-tetrahydrocannabinol and four synthetic cannabinoids, JWH-015, JWH-210, RCS-4, and JWH-250, were assessed using both the SPR biosensor assay and the conventional isotopic receptor binding assay. The binding affinities of the test substances to $CB_1$ were determined to be (from highest to lowest) $9.52{\times}10^{-3}M$ (JWH-210), $6.54{\times}10^{-12}M$ (JWH-250), $1.56{\times}10^{-11}M$ (${\Delta}^9$-tetrahydrocannabinol), $2.75{\times}10^{-11}M$ (RCS-4), and $6.80{\times}10^{-11}M$ (JWH-015) using the non-isotopic method. Using the conventional isotopic receptor binding assay, the same order of affinities was observed. In conclusion, our results support the use of kinetic analysis via SPR in place of the isotopic receptor binding assay. To replace the receptor binding affinity assay with SPR techniques in routine assays, further studies for method validation will be needed in the future.

Antioxidant, Anti-inflammation, and Anti-aging Effects of Ethyl Acetate Fraction from Cynanchum paniculatum Extracts (산해박 분획물의 항산화, 항염증 및 항노화 활성 효과 연구)

  • Jae Yong Seo;Go Eun Kim;Ji Soo Ryu;A Reum Jang;Su An Sim;Jung No Lee;Seunghee Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.1
    • /
    • pp.85-93
    • /
    • 2024
  • In this study, we prepared fractions from Cynanchum paniculatum (C. paniculatum) with ethyl acetate and identified the structure and content of paeonol, an indicator substance. Fractions were obtained by sequential solvent fractions using n-hexane, methylene chloride, ethyl acetate, n-butanol, and distilled water, and showed the highest paeonol content in ethyl acetate (EtOAc). The structure of the ethyl acetate fraction (EA) was confirmed by nuclear magnetic resonance (NMR) and the content was determined by high performance liquid chromatography (HPLC) analysis. The antioxidant activity of EA was tested through its ability to scavenge 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS), and its ability to inhibit nitric oxide (NO) production in RAW 264.7 cells induced by lipopolysaccharide (LPS) was tested for its ability to inhibit NO production in a concentration-dependent manner. Furthermore, MMP-1 production induced by ultraviolet B (UVB) was decreased in a concentration-dependent manner by the EA, and the ability to produce procollagen type-I was increased in a concentration-dependent manner. In addition, as a result of conducting clinical trials using cosmetic formulations containing EA, the effect of improving wrinkles around the eyes was confirmed. Thus, it is expected that Cynanchum paniculatum can be used as a natural functional cosmetic material with antioxidant and anti-aging effects.

Magnetic Resonance Imaging Factors Predicting Re-excision in Breast Cancer Patients Having Undergone Conserving Therapy (유방보존술을 시행받는 유방암환자에서 재절제 예측의 자기공명영상소견)

  • Jang, Mijung;Kim, Sun Mi;Yun, Bo La;Kim, Sung-Won;Kang, Eun Young;Park, So Yeon;Kim, Jee Hyun;Kim, Yeongmi;Ahn, Hye Shin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.133-143
    • /
    • 2014
  • Purpose : The aim of this study was to determine the magnetic resonance imaging (MRI) features associated with re-excision due to the presence of a positive margin after breast conserving therapy (BCT) in breast cancer patients. Materials and Methods: We reviewed the records of 286 consecutive breast cancer patients who received BCT between January 2006 and December 2007. Among 246 patients who had undergone BCT, 38 (15.4%) underwent immediate further surgery due to positive margin status. We analyzed the MRI findings using ${\chi}^2$ test, Fisher's exact test and t tests. Multivariate logistic regression was conducted for prediction of re-excision. Results: Tumor size (p < 0.001), lesion multiplicity (p = 0.003), and non-mass-like enhancement (NMLE) type on MRI (p < 0.001) were associated with margin involvement in BCT. On preoperative MRI, larger size (${\geq}5cm$) (odds ratio = 2.96), NMLE (odds ratio = 3.81), and multifocal lesions (odds ratio = 2.54) were positively associated with re-excision. In cases involving NMLE, segmental distribution was associated with a greater likelihood of immediate re-excision. Conclusion: Larger size, multiplicity, and NMLE on MRI are significantly associated with re-excision after BCT in breast cancer patients. For NMLE lesions, the segmental distribution pattern was predictive of re-excision.

Early Changes of Left Ventricular Geometry and Function after Surgical Ventricular Restoration and Mitral Valve Annuloplasty: Magnetic Resonance Imaging (외과적 심실 복원과 승모판 고리성형 후 좌심실 형태와 기능의 초기 변화: 자기공명영상)

  • Choi, Byoung-Wook;Chang, Byung-Chul;Kim, Young-Jin;Hur, Jin;Lee, Hye-Jeong;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Purpose : We sought to determine the early change of ventricular geometry and function after concomitant surgeries of modified Dor procedure and mitral valve annuloplasty by using magnetic resonance imaging. Materials and Methods : We enrolled 21 patients with dilated heart failure who underwent modified Dor procedure (n=8), mitral valve annuloplasty (n=6), or both surgeries (n=7). Cine MRI was used to assess left ventricular dimensions and function before and after surgery. We measured the left ventricular end-diastolic and end-systolic volumes and the dimensions of the left ventricular long-axis and short-axis. Left ventricular stroke volume, ejection fraction, and sphericity index were calculated from these measurements. These parameters were analyzed and compared between three different surgery groups to explain the combined effect of the concomitant surgeries. Results : MRI was performed within average $12\;{\pm}\;15$ days (range 1-58 days) before and $38\;{\pm}\;50$ days (range 7- 231 days) after the surgery. The patients who underwent concomitant surgeries had more profound enlargement of left ventricle and decreased contractility prior to surgery than those in the patients who underwent single surgical procedure. Left ventricular end-diastolic volume and endsystolic volume significantly decreased in all patients regardless of surgery type after surgery. Ejection fraction significantly increased only in the patients who got modified Dor procedure without mitral valve annuloplasty (25.4% to 40.7%). Sphericity index increased in patients with modified Dor procedure but decreased in patients with mitral valve annuloplasty (0.65 to 0.78 vs. 0.75 to 0.65). In the patients who underwent concomitant surgeries showed no significant change in sphericity index after surgery. Conclusion : The early change of the left ventricular geometry and function after the concomitant surgeries with modified Dor procedure and mitral valve annuloplasty in patients with dilated heart failure includes a marked reduction in left ventricular volume and in stroke volume. The shape of the left ventricle does not change because the effect of sphericity index decrease from mitral valve annuloplasty is counteracted by the effect of sphericity index increase from modified Dor procedure. Improvement of left ventricular ejection fraction is not the early change after the concomitant surgeries.

  • PDF

Study on Vibration Characteristics for Reducing Vibration of the Hopper-type Feeder (호퍼식급이기의 진동 저감을 위한 진동 특성 연구)

  • Lee, S.J.;Chang, D.I.;So, J.K.;Chang, H.H.;Yoon, T.J.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • This study was carried out to measure and analyze the vibration levels and modes produced by a hopper type feeder used at laying hen farms, to prevent the vibration resonance and to reduce the vibration of the hopper type feeder (6-tier). The most vibration in a layer house were produced by hopper type feeder as shown the previous study. According to the measurement results, the ratio of transmissibility was as high as 100-638% for natural frequency of 170 Hz or less. And vibration simulations were taken by the results of vibration mode analysis and the weakest points to vibrations were determined accordingly. Then measurement and analysis were taken for those points. The quantities of vibration were 4.6354-4.9118 g($g=9.81^m/s^2$) by axis. In this study, it was found that hopper type feeder generated vibration as much as to influence the ratio of laying eggs of layer. And by the analysis of vibration on the weakest points, design methods and equipment were suggested for isolating/reducing of vibration by each axis.

  • PDF

Wave Analysis and Spectrum Estimation for the Optimal Design of the Wave Energy Converter in the Hupo Coastal Sea (파력발전장치 설계를 위한후포 연안의 파랑 분석 및 스펙트럼 추정)

  • Kweon, Hyuck-Min;Cho, Hongyeon;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • There exist various types of the WEC (Wave Energy Converter), and among them, the point absorber is the most popularly investigated type. However, it is difficult to find examples of systematically measured data analysis for the design of the point absorber type of power buoy in the world. The study investigates the wave load acting on the point absorber type resonance power buoy wave energy extraction system proposed by Kweon et al. (2010). This study analyzes the time series spectra with respect to the three-year wave data (2002.05.01~2005.03.29) measured using the pressure type wave gage at the seaside of north breakwater of Hupo harbor located in the east coast of the Korean peninsula. From the analysis results, it could be deduced that monthly wave period and wave height variations were apparent and that monthly wave powers were unevenly distributed annually. The average wave steepness of the usual wave was 0.01, lower than that of the wind wave range of 0.02-0.04. The mode of the average wave period has the value of 5.31 sec, while mode of the wave height of the applicable period has the value of 0.29 m. The occurrence probability of the peak period is a bi-modal type, with a mode value between 4.47 sec and 6.78 sec. The design wave period can be selected from the above four values of 0.01, 5.31, 4.47, 6.78. About 95% of measured wave heights are below 1 m. Through this study, it was found that a resonance power buoy system is necessary in coastal areas with low wave energy and that the optimal design for overcoming the uneven monthly distribution of wave power is a major task in the development of a WEF (Wave Energy Farm). Finding it impossible to express the average spectrum of the usual wave in terms of the standard spectrum equation, this study proposes a new spectrum equation with three parameters, with which basic data for the prediction of the power production using wave power buoy and the fatigue analysis of the system can be given.

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF