• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.025 seconds

A Study on the Dynamic Stability of a Power Pack for Heavy Construction Equipments (토목공사용 파워팩의 동적 안정성에 관한 연구)

  • Kim, Dong-Il;Kim, Chae-Sil;Lee, Sang-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.134-138
    • /
    • 2014
  • Power packs can change energy to hydraulic energy generated by an engine as a tool for use with civil engineering construction equipment. This paper determines which type of power pack meets the standards of construction machinery. A power pack was formulated as a three-dimensional model by using the software CATIA. A modal analysis was conducted using ANSYS Workbench, and the resonance was checked. Next, a harmonic analysis was conducted. The analytical results show that the dynamic stability of the power pack is assured.

High b-value Diffusion Study of Normal Brain at 3 Tesla

  • 이영주;손철호;황문정;배성진;장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.83-83
    • /
    • 2002
  • 목적: 현재 임상적으로 사용되고 있는 확산경사자장의 세기 이상( > 1200)의 강한 확산 경사자장이 가해진 경우 뇌구조물들의 확산계수값을 조사하고 고자장(Bo = 3T)에서 이러한 강한 확산 경사자장을 이용하는 경우 1.5T에서 시행하는 경우와의 차이점을 비교 연구해보고자 하였다. 대상 및 방법: 정상 성인 3명을 대상으로 b-value를 0부터 3500까지 변화시키며 확산강조영상을 최대경사자장 40 mT/m, slew rate 150 T/m/s의 경사자장계가 장착된 3T MR scanner (General Electric, USA)에서 획득하였다. 사용한 펄스열은 Stejskal-Tanner type의 확산강조 경사자장이 포함된 single-shot SE EPI를 사용하였으며 영상획득시 사용한 파라미터는 다음과 같다. TR/TE= 10000/95.1, Thickness/space=512mm, FOV=24$\times$21cm, Matrix=128$\times$128, NEX=1 뇌구조물들에 관심 영역을 설정하고 b-value에 따른 신호감소를 측정하였다. 측정된 데이터를 hi-exponential decay 모델을 이용하여 분석하였다.

  • PDF

Magnetic Properties of High Electrical Resistive CoPdAlO Film for RF Device (높은 비저항을 갖는 RF 소자용 CoPdAlO 박막의 자기적 특성)

  • 김택수;이영우;김종오
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.109-113
    • /
    • 2001
  • Presently, an inductor adapted at MMIC (Monolithic Microwave Integrated Circuit) which is used for cellular phone or PHS operates at quasi-microwave range over 800 MHz. However, a W-CDMA (Wideband Code Division Multiple Access) will use about 2 GHz range. Therefore magnetic film device should be compatible up to 2 GHz. We have deposited Co-Pd-Al-O system film using rf sputtering method which is expected up to 2 GHz, and investigated the effect of Pd content and magnetic field annealing. When Pd composition is 19%, Hk was 118 Oe, and ${\mu}$′showed flat frequency characteristics up to 1.5 GHz. The Q factor (=${\mu}$′/${\mu}$") was 23.3 at 1 GHz, 6.7 at 1.5 GHz and 1.5 at 2 GHz, respectively. Resonance frequency was 2 GHz. Therefore Co-Pd-Al-O thin film could be used at over 1 GHz, and also expected as an inductor material for wide band CDMA type cellular phone.

  • PDF

The Soft Recovery Pulse Width Modulation Quasi Resonant Converter with Revised Folding Snubber Network (개선된 폴딩 스너버 망을 이용하여 소프트하게 역 복귀하는 의사 공진형 펄스 폭 컨버터)

  • Chung, Jin-Kuk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.62-66
    • /
    • 2010
  • A new soft recovery pulse width modulation quasi resonant converter composed only passive devices snubber network is proposed. This passive devices snubber network is revised form of folding snubber network that suppressed the reverse recovery current of main rectify diode in PWM converter. It also makes the MOSFET switching devices operate in soft state. The efficient of the proposed converter is almost same level to that of the converter of active snubber type. The overall circuit is simple and easy to realized. Therefore, it is suitable to apply to middle range output power source.

Synthesis of PSSQs Siloxane Resin Polymer Using Monomolecular Fluoro Silane

  • Bae, Jae Young;Mun, Han Jun;Kim, Tae Ho;Park, Hyun Ho
    • Elastomers and Composites
    • /
    • v.55 no.2
    • /
    • pp.103-107
    • /
    • 2020
  • Herein, resin-formed polysilsesquioxanes (PSSQs) were synthesized using monomolecular fluoro silane as a precursor. The synthesized PSSQs exhibited anti-smudge performance and were used as coating liquid. Two structures were acquired by controlling the amount of the silane precursor and the K2CO3 catalyst; these materials were used to prepare the anti-smudge coating liquid solution. The synthesized product was analyzed by various methods such as nuclear magnetic resonance spectroscopy, X-ray diffraction analysis, gel permeation chromatography, and water contact angle measurement. The results confirmed that the as-synthesized PSSQs exhibited the ladder structure and had a molecular weight of 5,117 g/mol and water contact angle of 102.31°.

Design and FEM Analysis of a Circular Piezoelectric Transformer with Crescent-Shaped Input Electrode (Crescent형 입력부를 가진 원형압전변압기의 설계 및 유한요소 해석)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1951-1953
    • /
    • 2005
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. The piezoelectric transformers operated in each transformer's resonance vibration mode. The electrodes and poling directions on commercially available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor $(k_p,\;k_{15})$ becomes effective rather than the transverse mode coupling factor ($k_{31}$). A single layer prototype transformer, 26[mm] in diameter and $1.5{\sim}4.0[mm]$ thick, was fabricated, such as step-up ratio, power transformation efficiency and temperature were measured.

  • PDF

Resonance inverter power system for plasma sterilization effective improvement (플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템)

  • Kim, J.Y.;Mun, S.P.;Kim, J.S.;Kim, Y.M.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Computer Simulation and MRA Observation for Steady Flow in the Carotid Arterial Bifurcation (경동맥 분지관내 정상유동에 대한 컴퓨터 시뮬레이션과 MRA 관찰)

  • Suh, S.H.;Cho, M.T.;Yoo, S.S.;Chung, T.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.73-76
    • /
    • 1996
  • Computer simulation and magnetic resonance angiograms(MRAs) are used to understand for flow patterns in the carotid arterial bifurcation. Steady momentum equation is solved by the finite volume method. A Phantom of the carotid artery made of bioacrylic material is used for MRA observation. Flow Patterns are observed by using MRA for flow in the phantom of an automatic closed-type circulatory system filled with sugar 4 w% solution. For numerical analysis the idealized geometric shape of the carotid artery is constructed to portray the phantom. Results of numerical analysis are compared with those of MRA. The flow patterns of the phantom on MRA are almost identical to those of the computer simulation.

  • PDF

The Research of Ultra Sonic Controller for Operating BLT (BLT를 구동하기 위한 초음파 제어기에 관한 연구)

  • 이종규;유태제
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.361-363
    • /
    • 2003
  • The purpose of this research was to discuss the system that operated Ultra sonic transducer of Pelzo electric ceramics type. The structure of controller was made up of digital signal part drive and feedback circuit, and half bridge inverter. Digital signal part was designed to gain the stable oscillation frequency by making consideration of pointed resonance bandwidth. We tried to control inverter by forward feedback condition because BLT based on the flexibility of elements such as temperature and load condition. In addition, transducer was operated as inverter in order to enhance its power efficiency. In this experiment, output voltage waveform and current waveform have been observed by using BLT.

  • PDF

Resonance Inverter Power System for Sterilization Effective Improvement of Plasma (플라즈마 살균 효과 향상을 위한 공전형 전원 시스템)

  • 김주용;문상필;정장근;이현우;서기영
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF