Analysis Model of a Piezoelectric Transducer with Incomplete Contact (압전 변환기의 내부 불완전 접촉을 고려한 해석 모델)

  • Kim, Dae-Seung;Kim, Jin-Oh
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.864-868
    • /
    • 2005
  • This paper develops an analysis model of a piezoelectric transducer. The transducer considered in this paper is a bolt-clamped Langevin-type transducer, which consists of a couple of piezoelectric discs, a couple of metal blocks for added mass effect, and a bolt to tighten them. A new analytical model for the transducer has been developed by taking into account the contact area between the piezoelectric ceramic and the metal block. The analysis model is verified by calculating the variations of the resonance frequency due to the contact area and comparing them with reported experimental results.

  • PDF

"Brain Stunning" Atypical Feature of tPA Thrombolysis Following Aneurysm Embolization

  • Park, Min-Woo;Yi, Hyeong-Joong;Gupta, Rishi;Horowitz, Michael B.
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.300-302
    • /
    • 2006
  • "Stunning" represents prolonged contractile depression of any muscular component after alleviation of severe ischemia, as shown in reperfusion following acute myocardial ischemia or ischemic stroke. Clinically, it presents with no or delayed recovery past to thrombolytic therapy but its pathogenic mechanism is not fully uncovered yet. We describe a unique case of a 63-year-old woman, who was undertaken endovascular coiling for the aneurysms, deteriorated several hours later without known cause, and showed delayed clinical improvement over the next 3 days following thrombolysis. Immediate post-thrombolysis magnetic resonance imaging scan showed no apparent abnormality except for high signal intensity within the corresponding hemisphere. Reversible but delayed nature of " brain stunning" can be explained by these images and it seems to be caused by a certain type of reperfusion injury.

A review of effects of partial dynamic loading on dynamic response of nonlocal functionally graded material beams

  • Ahmed, Ridha A.;Fenjan, Raad M.;Hamad, Luay Badr;Faleh, Nadhim M.
    • Advances in materials Research
    • /
    • v.9 no.1
    • /
    • pp.33-48
    • /
    • 2020
  • With the use of differential quadrature method (DQM), forced vibrations and resonance frequency analysis of functionally graded (FG) nano-size beams rested on elastic substrate have been studied utilizing a shear deformation refined beam theory which contains shear deformations influence needless of any correction coefficient. The nano-size beam is exposed to uniformly-type dynamical loads having partial length. The two parameters elastic substrate is consist of linear springs as well as shear coefficient. Gradation of each material property for nano-size beam has been defined in the context of Mori-Tanaka scheme. Governing equations for embedded refined FG nano-size beams exposed to dynamical load have been achieved by utilizing Eringen's nonlocal differential law and Hamilton's rule. Derived equations have solved via DQM based on simply supported-simply supported edge condition. It will be shown that forced vibrations properties and resonance frequency of embedded FG nano-size beam are prominently affected by material gradation, nonlocal field, substrate coefficients and load factors.

A Mechanistic Study for Aminolysis of p-Nitrophenyl Phenylacetate

  • 엄익환;Yeom, E. Suk;권혜진;권동숙
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.8
    • /
    • pp.865-868
    • /
    • 1997
  • Second-order rate constants have been measured spectrophotometrically for the reactions of p-nitrophenyl phenylacetate (1) and benzoate (2) with a series of alicyclic amines in H2O containing 20 mole % DMSO at 25.0 ℃. 1 appears to be more reactive than 2 toward all the amines studied, although phenylacetic acid is a weaker acid than benzoic acid. The higher reactivity of 1 can be attributed to resonance and/or steric effect, since the ground state of 2 can be stabilized by resonance and 1 would experience less steric hindrance due to the presence of CH2 group between phenyl and C=O group. The reactivity of the amines increases with increasing their basicity. The Bronsted-type plots for aminolysis of 1 and 2 show good linearity with βnuc values of 0.81 and 0.85, respectively, indicating that the TS structures of the aminolyses of 1 and 2 are similar. Besides, the linear Bronsted plots obtained in the present system clearly suggest that there is no mechanism change for the given series of the amines and the reactions of 1 and 2 proceed in a same mechanism.

Kinetics and Mechanism of the Pyridinolysis of Benzyl Bromides in Dimethyl Sulfoxide

  • 홍성완;고한중;이혜황;이익춘
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1172-1176
    • /
    • 1999
  • Nucleophilic substitution reaction of Y-benzyl bromide with X-pyridines are investigated in DMSO at 45.0℃. Biphasic rate dependence is observed on varying the substituents in the substrate (Y) as well as in the nucleophile (X). The two well-defined straight lines in the Hammett (ρy) and Bronsted ( βx) plots are interpreted to indicate the changes in transition-state structure, a decrease in bond cleavage as the substituent on the substrate is changed from electron-donors ( ρy < 0) to electron-acceptors ( ρy > 0), and an increase in the extent of bond formation with the corresponding changes of the substituent on the pyridine. A Jencks' type analysis of separate polar (ρ) and resonance (ρr) effects can also be accounted for by the change of the transition-state structure, not by the variable combination of polar and resonance effects.

Overhauser dynamic nuclear polarization for benchtop NMR system using a permanent magnet of 1.56 T

  • Lee, Yeon-seong;Lim, Duk-Young;Shim, Jeong Hyun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.3
    • /
    • pp.81-86
    • /
    • 2019
  • Overhauser dynamic nuclear polarization (O-DNP) has been an efficient method to boost the thermal nuclear polarization in liquids at room temperature. However, O-DNP for a benchtop NMR using a permanent magnet has remained unexplored yet. In this work, we report the development of an O-DNP system adopting a permanent magnet of 1.6 T. Q-band (~43 GHz) high-power amplifier produced 6 W microwave for saturation. Instead of resonator, we used an open-type antenna for the microwave irradiation. For several representative small molecules, we measured the concentration and frequency dependences of the enhancement factor. This work paves the way for the development of a benchtop DNP-NMR system overcoming its disadvantage of low quality signal when using a permanent magnet.

Computed Tomography and Magnetic Resonance Imaging Findings of Bicuspid Aortic Valve and Related Abnormalities of the Heart and Thoracic Aorta

  • You Jin You;Sung Min Ko
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.960-973
    • /
    • 2023
  • The bicuspid aortic valve (BAV) is the most common congenital cardiovascular malformation. Patients with BAV are at higher risk of other congenital cardiovascular malformations and valvular dysfunction, including aortic stenosis/regurgitation and infective endocarditis. BAV may also be related to aortic wall abnormalities such as aortic dilatation, aneurysm, and dissection. The morphology of the BAV varies with the presence and position of the raphe and is associated with the type of valvular dysfunction and aortopathy. Therefore, accurate diagnosis and effective treatment at an early stage are essential to prevent complications in patients with BAV. This pictorial essay highlights the characteristics of BAV and its related congenital cardiovascular malformations, valvular dysfunction, aortopathy, and other rare cardiac complications using multimodal imaging.

Development of Prepolarization Coil Current Driver in SQUID Sensor-based Ultra Low-field Magnetic Resonance Apparatuses (SQUID 센서 기반의 극저자장 자기공명 장치를 위한 사전자화코일 전류구동장치 개발)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.105-110
    • /
    • 2011
  • SQUID sensor-based ultra low-field magnetic resonance apparatus with ${\mu}T$-level measurement field requires a strong prepolarization magnetic field ($B_p$) to magnetize its sample and obtain magnetic resonance signal with a high signal-to-noise ratio. This $B_p$ needs to be ramped down very quickly so that it does not interfere with signal acquisition which must take place before the sample magnetization relaxes off. A MOSFET switch-based $B_p$ coil driver has current ramp-down time ($t_{rd}$) that increases with $B_p$ current, which makes it unsuitable for driving high-field $B_p$ coil made of superconducting material. An energy cycling-type current driver has been developed for such a coil. This driver contains a storage capacitor inside a switch in IGBT-diode bridge configuration, which can manipulate how the capacitor is connected between the $B_p$ coil and its current source. The implemented circuit with 1.2 kV-tolerant devices was capable of driving 32 A current into a thick copper-wire solenoid $B_p$ coil with a 182 mm inner diameter, 0.23 H inductance, and 5.4 mT/A magnetic field-to-current ratio. The measured trd was 7.6 ms with a 160 ${\mu}F$ storage capacitor. trd was dependent only on the inductance of the coil and the capacitance of the driver capacitor. This driver is scalable to significantly higher current of superconducting $B_p$ coils without the $t_{rd}$ becoming unacceptably long with higher $B_p$ current.

Invasive Lobular Carcinoma: MRI Features and Clinicohistological Characteristics According to the ER, PR, and HER2 Statuses

  • Yoo, Eun Young;Nam, Sang Yu;Choi, Hye-Young;Cho, Hyun Yee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.137-145
    • /
    • 2015
  • Purpose: To investigate correlations of estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor type 2 (HER2) statuses with magnetic resonance imaging (MRI) features and clinicohistological characteristics in patients with invasive lobular carcinoma (ILC). Materials and Methods: Data from 64 histologically confirmed ILCs were analyzed retrospectively. Preoperative breast MRI was reviewed for morphology and dynamic contrast-enhanced kinetics of the tumor. Pathologic reports were reviewed for ER, PR, and HER2 positivity, tumor size, lymph node metastasis, and the number of metastatic lymph nodes. Furthermore, there was an investigation of the MRI features and clinicohistologic characteristics, according to the ER, PR, and HER2 statuses. Results: A significant difference in MRI features and clinicohistological tumor characteristics were observed only in relation to PR status. Of the 64 ILCs, 10 (15.6%) were PR negative. PR negative cancers, compared with PR positive cancers, were more likely to present as non-mass enhancement (P = 0.027); have a significantly larger mean tumor size ($5.00{\pm}1.05cm$ vs. $2.57{\pm}0.21cm$, P = 0.021); and have significantly more metastatic lymph nodes (P = 0.010). Conclusion: PR negative ILC presented more frequently as non-mass enhancement on MRI, with larger tumors and increased numbers of metastatic lymph nodes. Therefore, the PR status plays an important role in determining MRI features and clinicohistological characteristics of ILC.

Analysis of transmission efficiency of the superconducting resonance coil according the materials of cooling system

  • Lee, Yu-Kyeong;Hwang, Jun-Won;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.46-49
    • /
    • 2016
  • The wireless power transfer (WPT) system using a magnetic resonance was based on magnetic resonance coupling of the transmission and the receiver coils. In these system, it is important to maintain a high quality-factor (Q-factor) to increase the transmission efficiency of WPT system. Our research team used a superconducting coil to increase the Q-factor of the magnetic resonance coil in WPT system. When the superconductor is applied in these system, we confirmed that transmission efficiency of WPT system was higher than normal conductor coil through a preceding study. The efficiency of the transmission and the receiver coil is affected by the magnetic shielding effect of materials around the coils. The magnetic shielding effect is dependent on the type, thickness, frequency, distance, shape of materials. Therefore, it is necessary to study the WPT system on the basis of these conditions. In this paper, the magnetic shield properties of the cooling system were analyzed using the High-Frequency Structure Simulation (HFSS, Ansys) program. We have used the shielding materials such as plastic, aluminum and iron, etc. As a result, when we applied the fiber reinforced polymer (FRP), the transmission efficiency of WPT was not affected because electromagnetic waves went through the FRP. On the other hand, in case of a iron and aluminum, transmission efficiency was decreased because of their electromagnetic shielding effect. Based on these results, the research to improve the transmission efficiency and reliability of WPT system is continuously necessary.