• 제목/요약/키워드: Resonance Suppression

검색결과 135건 처리시간 0.03초

Data fusion based improved HOSM observer for smart structure control

  • Arunshankar, J.
    • Smart Structures and Systems
    • /
    • 제24권2호
    • /
    • pp.257-266
    • /
    • 2019
  • The benefit of data fusion in improving the performance of Higher Order Sliding Mode (HOSM) observer is brought out in this paper. This improvement in the performance of HOSM observer, resulted in the improvement of active vibration control of a piezo actuated structure, when controlled by a Discrete Sliding Mode Controller (DSMC). The structure is embedded with two piezo sensors for measuring the first two vibrating modes. The fused output of sensors is applied to the HOSM observer for generating state estimates, these states generated are applied to the DSMC, designed for the fourth order linear time invariant model of the structure. In the simulation study, the structure is excited at the first and second mode resonance. It is found that better vibration suppression is obtained, when the states generated by the fused output of sensors is applied as controller input, than the vibration suppression obtained by applying the states generated by using individual sensor output. The closed loop performance of DSMC obtained with HOSM observer is compared with the closed loop performance obtained with the conventional observer. Results obtained shows that better vibration suppression is obtained when the states generated by HOSM observer is applied as controller input.

Corrugated CPW EBG 구조를 이용한 낮은 위상잡음과 향상된 고조파 특성을 갖는 새로운 형태의 발진기 (A Novel Oscillator Utilizing Corrugated CPW EBG Structure with Reduced Phase Noise and Improved Harmonic Characteristics)

  • 황철규;명로훈
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.101-106
    • /
    • 2005
  • This paper presents a new microwave oscillator incorporating a corrugated coplanar waveguide (CCPW) electromagnetic bandgap (EBG) structure as its terminating resonance component. The use of a compact CCPW EBG structure was effective in reducing the phase noise and improving the harmonic characteristics of the microwave oscillator circuit without additional backside processing and drastic size increment. The fully planar CCPW oscillator oscillating at the frequency of 5.41 GHz showed a phase noise characteristic of -90.7 dBc/Hz at 100kHz offset and a second harmonic suppression of 42.67 dB.

  • PDF

전자기 션트 감쇠기를 이용한 빔의 진동억제에 관한 연구 (Vibration Suppression of Beam by Using Electromagnetic Shunt Damper)

  • 성태홍;임승현;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.77-80
    • /
    • 2008
  • In this paper the electromagnetic shunt damper was newly employed for vibration suppression of the flexible structures. The electromagnetic shunt damper consists of a coil and a permanent magnet. The ends of the coil were connected to the RLC shunt circuit. The numerical solutions of resonant frequency of the shunt circuits were calculated by using Pspice. The vibration and damping characteristics of the flexible beams with the electromagnetic shunt damper were investigated by tuning the circuit parameters. Also, the effect of the magnetic intensity on the shunt damping was studied with the variation of the gap between the aluminum beam and the permanent magnet. Present results show that the magnet shunt damper can be successfully applied to reduce the vibration of the flexible structures.

  • PDF

Design of Balanced Dual-Band Bandpass Filter with Self-Feedback Structure

  • Chen, Xinwei;Han, Guorui;Ma, Runbo;Gao, Jiangrui;Zhang, Wenmei
    • ETRI Journal
    • /
    • 제31권4호
    • /
    • pp.475-477
    • /
    • 2009
  • A balanced dual-band bandpass filter based on ${\lambda}$/2 stepped-impedance resonators and open-loop resonators is proposed in this letter. By employing a type of self-feedback structure, an extra transmission zero is introduced near the common-mode resonance frequency, and the common-mode signal is suppressed. The measured results indicate that the filter can operate in 2.46 GHz and 5.6 GHz bands, and the insertion loss is 1.85 dB and 1.9 dB, respectively. Also, better common-mode suppression is achieved.

Silo 형 가스터빈 연소기에서 발생하는 연소진동 분석 및 저감 (Analysis of Combustion Oscillation and its Suppression in a Silo Type Gas Turbine Combustor)

  • 서석빈;안달홍;차동진;박종호
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.126-130
    • /
    • 2009
  • The present study describes an investigation into the characteristics of combustion oscillation and its suppression instability of a silo type gas turbine combustor in commercial power plant. Combustion oscillation is occurred the combustor in near full load during operation. As a result of FFT analysis of the combustion dynamics, the frequency of the oscillation is analyzed as the 1'st longitudinal mode of acoustic resonance of the combustor. For suppress of the instability, combustion tuning with adjust of fuel valve schedule is carried out, which changes equivalent ratio of each burners. As the result, the oscillation is successfully reduced with meeting the level of NOx emission regulation.

Design of Power Plane for Suppressing Spurious Resonances in High Speed PCBs

  • Oh Seung-Seok;Kim Jung-Min;Yook Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제6권1호
    • /
    • pp.62-70
    • /
    • 2006
  • This paper presents a new power plane design method incorporating a single geometry derived from a unit cell of photonic bandgap(PBG) structure. This method yields constantly wide suppression of parallel plate resonances from 0.9 GHz to 4.2 GHz and is very efficient to eliminate PCB resonances in a specified frequency region to provide effective suppression of simultaneous switching noise(SSN). It is shown that with only two cells the propagation of unwanted high frequency signals is effectively suppressed, while it could provide continuous return signal path. The measured results agree very well with theoretically predicted ones, and confirm that proposed method is effective for reducing EMI, with measured near-field distribution. The proposed topology is suitable for design of high speed digital system.

가공품질 향상을 위한 스마트폰 커버용 Machining Center Jig의 설계 개선 (Design Alterations of a Machining Center Jig for the Improved Surface Quality)

  • 윤현진;이일환;한대성;길사근;김영조
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.75-80
    • /
    • 2019
  • One of the most critical aspects of the smartphone industry is the quality of the cover. And the vibrations of machining center are supposed to be the most dominant factors to damage the cover quality. In this study, structure of a machining center has been analyzed through experiments and computer simulations to figure out the main reasons of the vibrations. And the design alterations based on the analysis were applied to identify the effects of those alterations on the vibration suppression. The result shows that the design alterations can effectively suppress about 90% of the vibrations.

발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법 (Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression)

  • 조경은;윤춘식;송호택;이영한;임대건;서진석;김성준
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.110-122
    • /
    • 2013
  • 목적: 발목관절 VISTA 자기공명영상을 이용하여 지방억제를 한 것과 하지 않은 VISTA 사이에서 정량평가를 하며, 발목 인대의 traceability 차이를 알아보고자 하였다. 대상과 방법: SNR의 비교를 위해 팬텀과 한명의 자원자에서 자기공명영상을 촬영하였다. CR (contrast ratio)과 인대 traceability 비교를 위해 발목 관절의 외상 과거력이 없는 10명의 자원자에서 자기공명영상을 촬영하였다. 모든 자기공명영상은 VISTA를 이용하였고 3T에서 촬영하였다. 지방억제는 SPAIR (Spectral Attenuated Inversion Recovery) 기법을 이용하였다. SNR은 피검자가 있을 때와 피검자 없이 촬영한 것으로 구하였다. CR은 열개의 오른쪽 발목관절의 관절액-힘줄, 관절액-연골, 관절액-인대, 지방-힘줄, 지방-연골, 지방-인대의 신호강도를 얻어 구하였다. 두 명의 근골격계 영상의학과 의사가 지방억제를 한 것과 하지 않은 영상을 calcaneofibular ligament (CFL)을 포함한 7개의 발목관절 인대에 대해서 점수를 매겼다 (1, not traceable; 2, barely traceable; 3, adequately traceable; 4, excellently traceable). VISTA 와 VISTA SPAIR 사이에 CR을 비교하는 데는 Wilcoxon signed-rank test를 이용하였다. VISTA 와 VISTA SPAIR사이에 인대 traceability를 비교하는 데에는 Fisher's exact test와 Pearson's chi-squared test를 이용하였다. 결과: 정량평가의 SNR을 보면 지방억제를 하지 않은 영상에 비해 지방억제를 한 자원자의 골수에서 더 낮은 수치를 나타내었다. (7.65 versus [vs.] 36.64). 관절액, 연골, 근육에서는 두 연쇄간에 SNR의 차이가 없었다. 지방억제 VISTA는 관절액-인대 사이 CR만 더 나은 결과를 보여주었지만 (p=0.04) VISTA는 지방-힘줄, 지방-연골, 지방-인대 간에서 모두 더 나은 CR값을 나타내었다(P=0.005). CFL 인대만 통계학적으로 의미 있는 값을 보였는데 지방억제를 하지 않은 VISTA 영상에서 traceability의 값이 더 우세 하였다(p <0.05). 결론: 지방 억제를 한 VISTA와 하지 않은 VISTA에서 유의한 SNR 차이는 골수를 제외하고 없었다. 지방억제를 하지 않은 VISTA에서 CFL을 trace하는데 있어서 더 유리하였다.

Simultaneous Spectral Resolution and Sensitivity Enhancement in MR spectrum: Maximum Likelihood Deconvolution Reconstruction

  • Jeong, Gwang-Woo;Jeong, Jenny Eunice;Kang, Heoung-Keun
    • 한국자기공명학회논문지
    • /
    • 제15권2호
    • /
    • pp.157-174
    • /
    • 2011
  • Although the use of apodization functions in connection with postprocessing of a 2D NMR spectrum proves improved spectral quality, there is usually a trade-off between resolution enhancement and noise suppression due to a classical "uncertainty principle." In this study, therefore, a mathematical deconvolution technique called "Maximum Likelihood Deconvolution (MLD)" was adopted to achieve the spectral resolution and sensitivity enhancement simultaneously. The MLD technique greatly facilitates visualization and restoration of the genuine spectral information from complex 2D NMR spectra that would be problematic with the conventional apodization/FT processing. In particular, application of the MLD to the 2D-NOE spectrum would be very useful to derive the important proton connectivities, which are essential to achieve elucidating the 3D molecular structure.

초고진공 전자 사이클로트론 공명 화학 기상증착장치의 제작과 수소 플라즈마를 이용한 실리콘 기판 표면 세정화 (Manufacturing of Ultrahigh Vacuum Electron Cyclotron Resonance Chemical Vapor Deposition Reactor and Si Wafer Surface Cleaning by Hydrogen Plasma)

  • 황석희;태흥식;황기웅
    • 전자공학회논문지A
    • /
    • 제31A권4호
    • /
    • pp.63-69
    • /
    • 1994
  • The Ultrahigh Vacuum Electron Cyclotron Resonance Chemical Vapor Deposition(UHV-ECRCVD) system whose base pressure is 1${\times}10^{9}$ torr has been constructed. In-situ cleaning prior to the epitaxial growth was carried out at 56$0^{\circ}C$ by ECR generated uniform hydrogen plasma whose density is $10^{10}/cm{3}$. The natural oxide was effectively removed without damage by applying positive DC bias(+10V) to the substrate. RHEED(Reflection High Energy Electron Diffraction) analysis has been used to confirm the removal of the surgace oxide and the streaky 2$\times$1 reconstruction of the Si surface, and the suppression of the substrate damage is anaylized by X-TEM(cross-sectional Transmission Electron Microscopy). Surface cleaning technique by ECR hydrogen plasma confirmed good quality epitaxial growth at low temperature.

  • PDF