• 제목/요약/키워드: Resonance Parameters

검색결과 754건 처리시간 0.026초

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제9권2호
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF

인두피판술 전.후의 공명파라미터의 비교: 예비연구 (A Comparison of Resonance Parameters before and after Pharyngeal Flap Surgery:A Preliminary Report)

  • 강영애;강낙헌;이태용;성철재
    • 말소리와 음성과학
    • /
    • 제1권3호
    • /
    • pp.133-144
    • /
    • 2009
  • Pharyngeal flap surgery changes the space and shape of the oral cavity and vocal tract, and these changing conditions bring resonance change. The purpose of this study was to determine the most reliable and valuable parameters for evaluating hypernasality to distinguish two patients before and after pharyngeal flap surgery. Each patient was asked to clearly speak the vowels /a/, /i/, /u/, /e/, /o/ for voice recording. There were nine parameters: Formant (F1, F2, F3), Bandwidth (BW1, BW2, BW3), LPC energy slope ($\Delta$ |A2-A1/F2-F1|), and Band Energy (0-500 Hz, 500-1000 Hz) by each vowel. From the results of discrimination analyses on acoustic parameters, the vowels /a/, /e/ appeared to be insignificant but vowels /i/, /u/, /o/ appeared to be efficient in the separation. A 95%, 100%, and 100% recognition score could be reached when vowels /i/, /u/, and /o/ were analyzed. The results showed that F2, BW3, and LPC slope are more important parameters than the others. Finally, there is a relation between perceptual evaluation score and LPC energy slope of acoustic parameters by least square slope.

  • PDF

Frequency-Domain Circuit Model and Analysis of Coupled Magnetic Resonance Systems

  • Huh, Jin;Lee, Wooyoung;Choi, Suyong;Cho, Gyuhyeong;Rim, Chuntaek
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.275-286
    • /
    • 2013
  • An explicit frequency-domain circuit model for the conventional coupled magnetic resonance system (CMRS) is newly proposed in this paper. Detail circuit parameters such as the leakage inductances, magnetizing inductances, turn-ratios, internal coil resistances, and source/load resistances are explicitly included in the model. Accurate overall system efficiency, DC gain, and key design parameters are deduced from the model in closed form equations, which were not available in previous works. It has been found that the CMRS can be simply described by an equivalent voltage source, resistances, and ideal transformers when it is resonated to a specified frequency in the steady state. It has been identified that the voltage gain of the CMRS was saturated to a specific value although the source side or the load side coils were strongly coupled. The phase differences between adjacent coils were ${\pi}/2$, which should be considered for the EMF cancellations. The analysis results were verified by simulations and experiments. A detailed circuit-parameter-based model was verified by experiments for 500 kHz by using a new experimental kit with a class-E inverter. The experiments showed a transfer of 1.38 W and a 40 % coil to coil efficiency.

원전 금속이물질 감시계통 센서 플레이트의 진동 특성 개선 연구 (Improvement of Vibration Response of a Sensor Plate of Loose Parts Monitoring System in Nuclear Power Plants)

  • 서정석;한순우;이정한;강토;박진호
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.148-154
    • /
    • 2017
  • This paper discussed design for resonance avoidance of sensor plates of loose-parts monitoring systems (LPMS) in nuclear power plants (NPP). An LPMS monitors impact of loose parts in primary loop of NPP by using accelerometers, which is mounted on sensor plates. Resonance of the plates may cause false alarms at frequencies over 10 kHz, which can be misunderstood as impact signals of loose parts with small mass and cause unnecessary response of NPP operators. Modal analysis was carried out for the existing sensor plate and design parameters affecting natural frequencies were chosen. Frequency response functions of plates were analyzed by changing the parameters and the optimized plate design for avoiding resonance was determined. Experiments was carried out for the plate specimen with improved design and verified the proposed approach and design.

TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선 (RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module)

  • 이동수
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.8-12
    • /
    • 2003
  • TO-can 레이저 다이오드를 사용한 광송수신기 모듈의 주파수 대역의 특성을 관찰하였다. 레이저 다이오드의 등가회로를 추출하기 위한 R-L-C변수는 임피던스 분석기를 이용하였다. 칩콘덴서를 사용하여 패키지내의 도선에 의한 인덕턴스 성분과의 임피던스 정합을 시도하였으나 저주파수 대역에서 공진으로 인한 경사가 발견되었다. 표면실장 형으로 소자를 구성하여 사용함으로써 공진주파수를 이동시켜 원하는 주파수 대역에서 공진 경사를 제거할 수 있었다.

Correction of resonance frequency for RF amplifiers based on superconducting quantum interference device

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.6-10
    • /
    • 2018
  • Low-noise amplifiers in the radio-frequency (RF) band based on the direct current (DC) superconducting quantum interference device (SQUID) can be used for quantum-limited measurements in precision physics experiments. For the prediction of peak-gain frequency of these amplifiers, we need a reliable design formula for the resonance frequency of the microstrip circuit. We improved the formula for the resonance frequency, determined by parameters of the DC SQUID and the input coil, and compared the design values with experimental values. The proposed formula showed much accurate results than the conventional formula. Minor deviation of the experimental results from the theory can be corrected by using the measured geometrical parameters of the input coil line.

Nonlinear vibration and primary resonance of multilayer functionally graded shallow shells with porous core

  • Kamran Foroutan;Liming Dai
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.335-351
    • /
    • 2023
  • This research studies the primary resonance and nonlinear vibratory responses of multilayer functionally graded shallow (MFGS) shells under external excitations. The shells considered with functionally graded porous (FGP) core and resting on two types of nonlinear viscoelastic foundations (NVEF) governed by either a linear model with two parameters of Winkler and Pasternak foundations or a nonlinear model of hardening/softening cubic stiffness augmented by a Kelvin-Voigt viscoelastic model. The shells considered have three layers, sandwiched by functionally graded (FG), FGP, and FG materials. To investigate the influence of various porosity distributions, two types of FGP middle layer cores are considered. With the first-order shear deformation theory (FSDT), Hooke's law, and von-Kármán equation, the stress-strain relations for the MFGS shells with FGP core are developed. The governing equations of the shells are consequently derived. For the sake of higher accuracy and reliability, the P-T method is implemented in numerically analyzing the vibration, and the method of multiple scales (MMS) as one of the perturbation methods is used to investigate the primary resonance. The results of the present research are verified with the results available in the literature. The analytical results are compared with the P-T method. The influences of material, geometry, and nonlinear viscoelastic foundation parameters on the responses of the shells are illustrated.

Parmeter Optimization for Calculation of Proton Chemical Shift in Protein

  • Park, Kyunglae;Wil
    • 한국자기공명학회논문지
    • /
    • 제1권2호
    • /
    • pp.71-78
    • /
    • 1997
  • The magnetic anisotropy effects of peptide group in structured protein on proton chemical shift have been investigated using trialanine modeling. The structure dependent part of chemical shift of C${\alpha}$H of the second amino acid residue was assumed to come purely from the magnetic anisotropy effects of C=O and C-N bonds of peptide in the direct neighborhood and thus to be dependent on and $\psi$ angle of this dipeptide. A set of dipeptide models with different and $\psi$angles were generated and from these models the chemical shift values were calculated using known algorithm to emphasize the role of parameters used in the equation. Comparison of sets of different parameters resulted in an optimized parameters which could reproduce the statistical chemical shift values observed in proteins with respect ot the secondary conformation.

  • PDF

Elucidating the Dynamic Properties of Globular Protein using Predicted Order Parameters and 15N NMR Relaxation

  • Yi, Jong-Jae;Kim, Won-Je;Rhee, Jin-Kyu;Lim, Jongsoo;Lee, Bong-Jin;Son, Woo Sung
    • 한국자기공명학회논문지
    • /
    • 제21권1호
    • /
    • pp.26-30
    • /
    • 2017
  • Dynamic properties of proteins can present key information on protein-ligand and protein-protein interaction. Despite their usefulness, the properties of protein dynamics have not been obtained easily due to protein stability and short-term measurement. Here, it is shown that combined method for analysis of dynamical properties. It utilizes predicted order parameter and NMR relaxation data such as $T_1$, $T_2$, and heteronuclear NOE. The suggested method could be used to know the flexibility of protein roughly without precise dynamical parameters such as order parameters through model-free analysis.