• Title/Summary/Keyword: Resonance Mode

검색결과 807건 처리시간 0.029초

Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film

  • Bogdanowicz, Robert;Sobaszek, Michał;Ficek, Mateusz;Gnyba, Marcin;Ryl, Jacek;Siuzdak, Katarzyna;Bock, Wojtek J.;Smietana, Mateusz
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.705-710
    • /
    • 2015
  • The fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ℃. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD films and mean grain size in the range of 100-250 nm. The films deposited on the glass reference samples exhibit high refractive index (n=2.05 at λ=550 nm) and low extinction coefficient. Furthermore, cyclic voltammograms (CV) were recorded to determine the electrochemical window and reaction reversibility at the B-NCD fiber-based electrode. CV measurements in aqueous media consisting of 5 mM K3[Fe(CN)6] in 0.5 M Na2SO4 demonstrated a width of the electrochemical window up to 1.03 V and relatively fast kinetics expressed by a redox peak splitting below 500 mV. Moreover, thanks to high-n B-NCD overlay, the coated fibers can be also used for enhancing the sensitivity of long-period gratings (LPGs) induced in the fiber. The LPG is capable of measuring variations in refractive index of the surrounding liquid by tracing the shift in resonance appearing in the transmitted spectrum. Possible combined CV and LPG-based measurements are discussed in this work.

메타 물질 기법을 이용한 전방향성 복사 패턴을 갖는 평면형 S-DMB 안테나 설계 및 구현 (Design and Implementation of Plannar S-DMB Antenna with Omni-Directional Radiation Pattern Using Metamaterial Technique)

  • 안찬규;유주봉;전준호;김우찬;양운근;나병구;이재호
    • 한국전자파학회논문지
    • /
    • 제21권12호
    • /
    • pp.1343-1351
    • /
    • 2010
  • 본 논문에서는 metamaterial CRLH(Composite Right- and Left-Handed) 구조 기반의 새로운 패치 안테나를 설계 제작하여 측정하였다. 일반 마이크로스트립 패치 구조의 기본 공진 모드인 반파장 공진이나 반파장 공진의 양의 정수배와 달리 제안된 안테나는 구조 전체에 전계가 같은 위상을 갖게 한다. 본 논문에서 제안하는 안테나는 요구되는, $\lambda/4$ 모노폴 안테나의 전형적인 특성인 전방향 패턴을 갖는 동시에 low-profile의 장점을 가진다. 제안된 안테나의 전산 모의 실험에는 Ansoft사의 FEM(Finite Element Method) 방식의 HFSS(High Frequency Structure Simulator)를 사용하였다. 제안된 안테나는 두께 1.6 mm, 유전율 4.4의 FR-4 기판을 사용하여 제작하였다. 구현된 안테나는 S-DMB(Satellite-Digital Multimedia Broadcasting) 서비스에서 사용되는 2.63~2.655 GHz에서 VSWR(Voltage Standarding Wave Ratio)$\leq$2임을 만족하며, 측정된 최대 이득과 효율은 각각 2.65 dBi와 81.14 %이다.

중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가 (Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes)

  • 이삼철;권오성;김호철;황영실;이현철
    • 멤브레인
    • /
    • 제15권3호
    • /
    • pp.224-232
    • /
    • 2005
  • 생체 폐를 대신해서 임시적으로 제공하는 폐 보조 장치(LAD)의 사용은 기계 환기술의 단순화와 체외순환 막형 인공폐의 기능을 결합하여 급성호흡부전 환자에 적합하다. 본 연구에서의 주 관심은 폐 보조 장치에서의 막 진동 효율에 있었으며 정량적인 실험 측정은 혈액 용혈에 대한 막 진동 의존을 확인하기 위하여 실행하였다. 또, 혈액 용혈은 막 진동이 이루어질 때 한계 용혈의 가진 주파수 대에서 결정하였다. 최대 기체 전달율을 보이는 675의 중공사 막으로 이루어져 있는 유형 5의 가진 주파수에서 최대 진폭의 발생 및 중공사에 진동의 전달에 의해 최대 산소 전달율이 일어났다. 이 주파수가 혈류량에 가동 가능했던 제 2 형태의 공진 주파수가 되어 높은 각 혈류량 비에서 $25{\pm}5$ 헤르쯔까지 가진이 되었으며, 혈액 용혈은 $25{\pm}5$ 헤르쯔의 가진 주파수에서 상대적으로 낮았다. 따라서 우리는 이 폐 보조 장치의 한계 용혈 주파수가 $25{\pm}5$ 헤르쯔인 것으로 결정했다.

JPEG 표준안을 이용한 의료 영상 압축 (Medical Image Compression Using JPEG International Standard)

  • 안창범;한상우;김일연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.504-506
    • /
    • 1993
  • JPEG(Joint Photographic Experts Group) 표준안은 디지털 정지 압축을 위하여 국제표준화기구(ISO/SC29/WG10)와 국제전신전화 자문회의(CCITT SG VIII)에 의해서 제안되었다. JPEG 표준안은 전자영상, 컴퓨터 그래픽, 멀티미디어 등과 관련하여 널리 응용되고 있으나, 의료 영상분야에서는 JPEG 압축의 손실 특성 때문에 사용이 매우 제한적이었다. 본 논문에서는 JPEG 표준안을 핵자기 공명 단층 영상 (256 gray levels, $256{\times}256$ size) 압축에 적용하여 그 성능을 조사하였다. 이를 위하여 JPEG 표준안 중 DCT에 기반을 둔 순차식 부호화 압축을 C-Cube Microsystems의 CL550 chip을 사용하여 구현하였고, 점진식 및 무손실 부호화 방식은 특별한 Hardware 없이 Software로 구현하여 실험하였다. 본 실험을 통하여 핵자기 공명 단층 시험 영상에 대해 거의 왜곡없이 약 10-20 정도의 압축률이 얻어짐을 확인할 수 있었다. 특히 JPEG으로 압축하였을 경우 재구성한 영상과 원영상과의 에러 신호가 random noise에 가깝게 나타남으로써 특별한 artifact가 없는 것도 JPEG의 큰 장점으로 부각된다. 한편 JPEG의 점진식 및 게층식 부호화 방식은 압축률과 신호대 잡음비에 있어서는 순차식과 동일하나, 거대한 영상 데이터 베이스 내에서의 빠른 탐색과 비교적 속도가 느린 공중망을 통한 원격 진단에 유용한 특성을 갖는다.

  • PDF

A Conserved Mechanism for Binding of p53 DNA-Binding Domain and Anti-Apoptotic Bcl-2 Family Proteins

  • Lee, Dong-Hwa;Ha, Ji-Hyang;Kim, Yul;Jang, Mi;Park, Sung Jean;Yoon, Ho Sup;Kim, Eun-Hee;Bae, Kwang-Hee;Park, Byoung Chul;Park, Sung Goo;Yi, Gwan-Su;Chi, Seung-Wook
    • Molecules and Cells
    • /
    • 제37권3호
    • /
    • pp.264-269
    • /
    • 2014
  • The molecular interaction between tumor suppressor p53 and the anti-apoptotic Bcl-2 family proteins plays an essential role in the transcription-independent apoptotic pathway of p53. In this study, we investigated the binding of p53 DNA-binding domain (p53DBD) with the anti-apoptotic Bcl-2 family proteins, Bcl-w, Mcl-1, and Bcl-2, using GST pull-down assay and NMR spectroscopy. The GST pull-down assays and NMR experiments demonstrated the direct binding of the p53DBD with Bcl-w, Mcl-1, and Bcl-2. Further, NMR chemical shift perturbation data showed that Bcl-w and Mcl-1 bind to the positively charged DNA-binding surface of p53DBD. Noticeably, the refined structural models of the complexes between p53DBD and Bcl-w, Mcl-1, and Bcl-2 showed that the binding mode of p53DBD is highly conserved among the anti-apoptotic Bcl-2 family proteins. Furthermore, the chemical shift perturbations on Bcl-w, Mcl-1, and Bcl-2 induced by p53DBD binding occurred not only at the p53DBD-binding acidic region but also at the BH3 peptide-binding pocket, which suggests an allosteric conformational change similar to that observed in Bcl-$X_L$. Taken altogether, our results revealed a structural basis for a conserved binding mechanism between p53DBD and the anti-apoptotic Bcl-2 family proteins, which shed light on to the molecular understanding of the transcription-independent apoptosis pathway of p53.

해수소통구를 구비한 진동수주형 파력발전구조물 내에서 공기흐름과 구조물 주변에서 파랑특성에 관한 3차원수치해석(규칙파의 경우) (3-Dimensional Numerical Analysis of Air Flow inside OWC Type WEC Equipped with Channel of Seawater Exchange and Wave Characteristics around Its Structure (in Case of Regular Waves))

  • 이광호;이준형;정익한;김도삼
    • 한국해안·해양공학회논문집
    • /
    • 제30권6호
    • /
    • pp.242-252
    • /
    • 2018
  • 진동수주형의 파력발전구조물(OWC-WEC)는 파랑에너지 흡수장치 중에 가장 효율적인 것으로 알려져 있다. 이 장치는 공기실 내부에서 해수면의 상 하운동을 공기흐름으로 변환하고, Wells 터빈으로 대표되는 터빈의 구동력으로부터 전기에너지가 생산된다. 따라서, 높은 전기에너지를 얻기 위해서는 공기실 내부에서의 수면변동에 피스톤모드의 공진을 유발시켜 수면진동을 증폭시킬 필요가 있다. 본 연구에서는 해수소통구를 구비한 신형식의 OWC-WEC를 상정하고, 구조물에 의한 파랑변형, 공기실 내에서 수면변동과 노즐에서 공기유출속도 및 해수소통구에서 해수흐름속도를 수치해석적으로 상세히 평가한다. 수치해석모델은 Navier-Stokes solver의 혼상류해석기법에 기초한 공개 CFD code인 OLAFLOW 모델을 적용하며, 모델의 타당성을 검증하기 위하여 기존의 실험결과 및 수치해석결과와를 비교 논의한다. 본 연구의 범위 내에서 Ursell수가 커질수록 노즐에서 공기흐름속도가 증가하며, 공기실 내부에서 외부로 유출되는 공기속도가 외부에서 공기실 내부로 유입되는 공기속도보다 더 크다 등의 중요한 사실을 알 수 있었다.

3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견 (Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.120-128
    • /
    • 2002
  • 목적 : 성상세포종과 다형성교모세포증과 같은 뇌종양에서 37 양성자 자기공명분광법을 이용한 분광 소견을 알아보고, 이를 정상인 뇌의 분광소견과 비교하여, 그 차이를 알아보고자 하였다. 대상 및 방법 : 대상환자는 가톨릭의대 부속 강남성모병원에서 2001년 1월 1일부터 2002년 6월 1일까지 조직학적으로 확인된 astrocytoma 및 glioblastoma multiforme (GM) 환자들 중에서 양성자 자기공명분광을 시행한 10명의 환자를 대상으로 하였다. 연령분포는 28세에서 73세(평균: 52.2세), 남녀비는 4:6이었다. 양성자 자기공명분광법은 전신용 3T MRI/MRS 시스템(Medinus Co., LTD. Magnus 2.1)과 STEAM (stimulated echo acquisition mode) pulse sequence를 사용하였다. 획득한 자기공명분광 소견은 각각의 군에서 N-acetyla-spartate (NAA), phosphocreatine and creatine (Cr), choline containing compounds (Cho) and lactate (Lac)와 같은 대사물질들을 Cr을 기준으로 대사산물 신호강도의 비율로 상대적으로 계측하였다. 각각의 군에서 상대적인 비율의 평균과 표준편차를 구하여 정상뇌와 뇌종양을 비교하였고, 종합적인 결과는 Student t-test로 통계 처리하였다. 결과 : 양성자 자기공명분광소견상 정상 뇌조직과 뇌종양의 Cho/Cr 평균값은 각각 1.16$\pm$0.15, 1.79$\pm$1.02로 측정되었고, NAA/Cr은 각각 1.67$\pm$0.18, 0.64$\pm$0.38로 측정되었다. Lactate는 정상 뇌조직에서는 거의 발견되지 않은데 비해 뇌종양에서는 모두 관찰되었고 그 양은 3.53$\pm$2.54로 높게 나타났다. 결론 뇌종양(성상세포종, 다형성교모세포증)은 정상 뇌조직에 비해 Cho/Cr 비율이 현저히 증가하였으며, NAA/Cr 비율은 감소하였다. 또한 뇌종양에서는 강한 Lactate signal을 보여 주었다. 양성자 자기공명분광은 뇌종양에 대한 생화학적 정보를 얻을 수 있으므로, 임상적으로 비침습적인 방법을 통한 진단뿐 만 아니라 치료후 효과 판정이나, 뇌종양 재발 등의 감별진단에도 이용할 수 있을 것으로 사료된다.

  • PDF