• Title/Summary/Keyword: Resonance Characteristics

Search Result 1,874, Processing Time 0.032 seconds

Experimental Study on Sloshing Characteristics of a Ferrofluid in the Spherical Container (구형 용기 내 자성유체의 슬로싱 특성에 관한 실험적 연구)

  • Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.5
    • /
    • pp.173-177
    • /
    • 2013
  • This work describes the experimental investigations on sloshing characteristics of water and ferrofluid as working fluids in the spherical container with the horizontal oscillation motion and compared the results obtained by two working fluids. In order to Investigate the sloshing characteristics of the sphere container with the horizontal oscillation, experiments are performed with the magnetic intensities from 0 mT to 50 mT and horizontal oscillation motions from 5 mm to 15 mm. As results, Ferrofluid without magnetic field in the sphere container showed a similar liquid surface movement with water. The resonance point of the ferrofluid in the sphere container happened at higher value than that of the theoretical resonance frequency with the rise of the magnetic field. In addition, the sloshing characteristics of the ferrofluid in the sphere container can be controlled with the resonance frequency with the magnetic intensity and the liquid surface displacement could be also controlled.

Actuating Characteristics of an Asymmetric Optical Pick-up Fine Actuator of a High Speed CD-ROM (고배속 CD-ROM용 비대칭형 광픽업 미세구동기의 구동특성)

  • 고상선;류제하;박기환;정호섭
    • Journal of KSNVE
    • /
    • v.8 no.2
    • /
    • pp.346-352
    • /
    • 1998
  • This paper presents actuating characteristics of an asymmetric high-speed optical pick-up fine actuator that can be installed in a small area such as a notebook personal computer. In the asymmetric actuator four points (mass center, actuation center, supporting point of wire suspension on a bobbin, and optical axis) are not coincident so that the proposed actuator suspension reveals undesirable suspension resonance in the pitch and yaw direction. Lumped parameter dynamic model in each direction is used to investigate the driving characteristics with respect to relative location of the four points. Some of desired design directions toward reducing resonance peaks are suggested by using sensitivity information. In order to avoid undesirable resonance, at least supporting point on the obbin must be located in the middle of the mass and actuation center of the asymmetric pick-up actuator.

  • PDF

Cobalt (Co) Electrode FBAR Devices Fabricated on Seven-Layered Bragg Reflectors and Their Resonance Characteristic

  • Mai Linh;Munhyuk Yim;Kim, Dong-Hyun;Giwan Yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.381-384
    • /
    • 2003
  • In this paper, cobalt (Co)-electrode FBAR devices fabricated on seven-layered Bragg Reflectors are presented along with their resonance characteristics. ZnO films are used as the resonating material in FBAR devices where the Co electrode is 3000$\AA$ thick. All processes are preformed in an RF magnetron sputtering system. As a result of characterization, the resonance characteristics are observed to depend strongly on the quality of ZnO film and Bragg Reflectors. In addition, the FBAR devices with W/SiO$_2$ reflectors show good resonance characteristics in term of return loss and quality-factor (Q-factor).

  • PDF

Electrical Characteristics of Disk-type Piezoelectric Transformer Poled with the Same Direction (동일 방향으로 분극된 디스크형 압전변압기의 전기적 특성)

  • 이종필;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.688-692
    • /
    • 2003
  • For high voltage operation, a new type of piezoelectric transformer using radial vibration of disk, poled with the same direction was proposed. The piezoelectric ceramics was composed to PZT-PMN-PSN. The diameter and thickness of a disk type piezoelectric transformer were 45[mm]and 4[mm], respectively The surface ratio of driving electrode and generating electrode of the piezoelectric transformer was 2 : 1. The resonance characteristics of input admittance, step-up voltage ratio and power transmission efficiency of the piezoelectric transformer were measured by varying the load resistance(0.1∼70[kΩ]). As a result, both resonance frequency and step-up voltage ratio increased with increasing load resistance. The step-up voltage ratio was reached more than 60 times under no load resistance. The maximum efficiency of 97% at load resistance of 2kΩ was obtained.

Resonance Characteristics of ZnO-Based FBAR Devices by Two-Step Annealings

  • Song, Hae-Il;Mai, Linh;Yoon, Gi-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.371-375
    • /
    • 2005
  • In this paper, the resonance characteristics of ZnO-based FBAR devices are compared. Several FBAR device samples were fabricated by using three different annealing methods while one sample remained non-annealed as a reference for comparison. Resonance characteristics could be significantly improved by both Bragg reflector-annealing and/or post-annealing steps. Especially, the use of two-step annealings resulted in most desirable resonance characteristic improvement compared with the Bragg reflector-annealing or post-annealing step alone.

  • PDF

Fabrication Techniques and Their Resonance Characteristics of FBAR Devices

  • Yoon, Gi-Wan;Song, Hae-Il;Lee, Jae-Young;Mai, Linh;Kabir, S. M. Humayun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.204-207
    • /
    • 2007
  • Film bulk acoustic wave resonator (FBAR) technology has attracted a great attention as a promising technology to fabricate the next-generation RF filters mainly because the FBAR technology can be integrated with current Si processing. The RF filters are basically composed of several FBAR devices connected in parallel and in series, and their characteristics depend highly on the FBAR device characteristics. Thus, it is important to design high quality FBAR devices by device or process optimization. This kind of effort may enhance the FBAR device characteristics, eventually leading to FBAR filters of high performance. In this paper, we describe the methods to more effectively improve the resonance characteristics of the FBAR devices.

  • PDF

Analysis of Resonance Characteristics of Bulk Acoustic Resonator with Acoustic Bragg Reflector for Biosensor Development (바이오센서 개발을 위한 음향 브래그 반사층을 가지는 체적탄성파 공진기의 공진특성 분석)

  • Kim, Hee-Young;Kim, Ki-Bok;Ha, Tae-Hoon;Kim, Yong-Il;Lee, Jin-Min;Kim, Man-Soo
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • As a basic study to develop a high sensitive biosensor using film bulk acoustic resonator, the mathematical model for analyzing the resonance characteristics of bulk acoustic resonator with acoustic Bragg reflectors was investigated. The simulation results due to the number of acoustic Bragg reflectors with low and high acoustic impedance materials were compared with the experimental results for 1, 2.25 and 5 MHz of PZT based bulk acoustic resonators with various acoustic Bragg reflectors. At the fabricated bulk acoustic resonator with an odd number of acoustic Bragg reflectors, low and high acoustic impedance materials in sequence under the bottom electrode showed better resonance characteristics than even number of acoustic Bragg reflectors. The changes of resonance frequencies due to the increase of number of acoustic Bragg reflectors by simulation and experiment, respectively showed approximately similar tendency but some differences in input impedance between the experiment and simulation were found. The derived mathematical model for describing the resonance characteristics of the bulk acoustic resonator with acoustic Bragg reflector will be available for analyzing the design parameters for development of biosensor using bulk acoustic resonator.

Noise Reduction Characteristics of a High-performance Air-gap Resonator (고효율 에어갭 공명기의 소음 저감 특성)

  • Kang, Sang-Wook;Lee, Jang-Moo;Lim, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.118-124
    • /
    • 2004
  • The objective of the paper is to demonstrate the noise reduction characteristics of an air-gap resonator, which is composed of an air gap and a partition sheet. By means of installing the air-gap resonator in an enclosed cavity, acoustic resonance can be effectively suppressed using a small space. In particular, it is revealed from a simple, one-dimensional model that the air-gap resonator serves as the Helmholtz resonator that generally absorbs acoustic resonance energy at its resonance frequency. As a result, the air-8ap resonator also has a resonance frequency, which can be predicted with a simple frequency equation derived in the paper. Finally, verification experiments show that the air-gap resonator can be effectively designed by predicting a reasonable gap thickness using the simple frequency-equation.

Operational Characteristics of Flux-lock Type SFCL using Series Resonance

  • Lim, Sung-Hun;Han, Byoung-Sung;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.4
    • /
    • pp.159-163
    • /
    • 2005
  • We analyzed the fault current limiting characteristics of a flux-lock type $high-T_c$ super­conducting fault current limiter (HTSC-FCL) using series resonance between capacitor for series resonance and magnetic field coil which was installed in coil 3. The capacitor for the series resonance in the flux-lock type HTSC-FCL was inserted in series with the magnetic field coil to apply enough magnetic field into HTSC element, which resulted in higher resistance of HTSC element. However, the impedance of the flux lock type HTSC-FCL has started to decrease since the current of coil 3 exceeded one of coil 2 after a fault accident. The decrease in the impedance of the FCL causes the line current to increase and, if continues, the capacitor for the series resonance to be destructed. To avoid this operation, the flux-lock type HTSC-FCL requires an additional device such as fault current interrupter or control circuit for magnetic field. From the experimental results, we investigated the parameter range where the operation as mentioned above for the designed flux-lock type HTSC-FCL using series resonance occurred.

Acoustic resonance and refrigerating capability of a Hofler type thermoacoustic refrigerating system (Hofler 타입 열음향 냉장시스템의 공진특성과 냉장성능)

  • Hah, Zae-Gyoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.76-80
    • /
    • 1997
  • Acoustic resonance characteristics were analyzed and their effect on the refrigerating capability were experimentally verified on a fabricated Hofler-type thermoacoustic refrigerating system. Factors governing the overall resonance are the resonator composed of a cavity and two pipes, the loudspeaker driving the resonator, and rear side impedance characteristics of speaker housing. All these are coupled with electric constants of the speaker to exhibit electric resonance. Also the 'wall-effect' within the resonator causes attenuation to reduce the sharpness of the resonance. Analysis and experiments showed housing and the wall-effect of the resonator reduce the sharpness of resonance. Maintaining the accuracy of the resonance is, therefore, very important for efficient refrigeration.

  • PDF