• Title/Summary/Keyword: Resonance

Search Result 11,589, Processing Time 0.047 seconds

Urachal Anomalies in Children (소아 요막관 기형)

  • Kang, Eun-Young;Lee, Cheol-Koo;Park, Kwan-Hyeon;Seo, Jeong-Meen;Lee, Suk-Koo
    • Advances in pediatric surgery
    • /
    • v.11 no.2
    • /
    • pp.150-156
    • /
    • 2005
  • Failure of the urachus to regress completely results in anomalies that may be classified as patent urachus, urachal sinus, urachal cyst and bladder diverticula. The presenting symptoms of children with urachal anomalies are variable and uniform guidelines for diagnosis and treatment are lacking. The purpose of this study was to analyze our experience and develop conclusions regarding the presentation, diagnosis and treatment of urachal anomalies. We retrospectively analyzed the records of 32 patients who were admitted for urachal anomalies from March 1995 to February 2005. The age distribution of these patients at presentation ranged from 1 day to 14 years old (median age 1 month). There were 20 boys and 12 girls. The 32 cases comprised 13 cases of urachal sinus (40.6 %), 10 urachal cyst (31.3 %), and 9 patent urchus (28.1 %). In 30 patients ultrasonography was used for diagnosis and 2 patients with patent urachus were explored without using a diagnostic method. Twenty-three patients were confirmed by ultrasonography alone and 7 patients were examined using additional modalities, namely, computed tomography for 2 patients with an urachal cyst, magnetic resonance imaging for 1 patient with an urachal cyst, and fistulography for 3 patients with an urachal sinus. The presenting symptoms were umbilical discharge (14 patients), umbilical granuloma (8), abdominal pain and fever (3), fever (3), abdominal pain (2), and a low abdominal mass (2). Excision was performed in 29 patients, and 3 patients were conservatively managed. Urachal anomalies in children most frequently presented in neonates, and the most common complaint was umbilical discharge with infection. Urachal anomalies can be diagnosed by a physical examination and an appropriate radiographic test. Ultrasound was the most useful diagnostic method. Complete surgical excision of an urachal anomaly is recommended to avoid recurrence, and the rare development of carcinoma.

  • PDF

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I (이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I)

  • Kim, Si-Yeob;Kim, Byung-Kook;Heo, Jin-Ho;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.327-336
    • /
    • 2007
  • Purpose This study was planned to compare and evaluate the stability of implant using $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Material and methods Artificial bone and RBM(resorbable blasting media) surface blasted implants(Osstem US II, SS II implants - diameter: 4mm, length: 13mm) were used. To measure the stability of installed implants, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ were used. In the first experiment, five implants were installed in D1(external type implants) and D3(internal type implants). In the second experiment, 4 internal type implants were divided in two groups and installed in D1 artificial bone with different depth. In the third experiment, two external implants were installed in D1 and D3 artificial bone each and two internal implants were installed in D1 and D3 artificial bone. In all groups, their stability were measured by $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Results In all groups, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ both showed reliable measurement values. The value difference between $Osstell^{TM}$ and Osstell $Mentor^{TM}$ was observed but the difference was small and clinically acceptable. Conclusion These results suggest that the use of Osstell $Mentor^{TM}$ has clinical relevance in the assessment of implant stability.

Effects of Surface Microstructure on Microwave Dielectric Properties of ZrO2-NiO added Ba(Zn1/3Ta2/3)O3 Ceramics (ZrO2와 NiO가 첨가된 Ba(Zn1/3Ta2/3)O3에서 표면 미세조직이 고주파 유전특성에 미치는 영향)

  • Kang, Sung-Woo;Kim, Tae-Heui;Moon, Joo-Ho;Kim, Sung-Youl;Park, Jun-Young;Choi, Sun-Hee;Kim, Joo-Sun
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.11
    • /
    • pp.701-706
    • /
    • 2008
  • High frequency dielectric ceramics have potential for applications in mobile and satellite communications systems at frequencies higher than 10GHz. The Ba$(Zn_{1/3}Ta_{2/3})O_3$ ceramics are known to have a high quality factor, a small temperature coefficient of the resonance frequency and a high dielectric constant. On the other hands, sintering at high temperature for extended time is required to obtain the ordered structure for high quality factor. In this study, the microwave dielectric properties of $ZrO_2$ and NiO-added Ba$(Zn_{1/3}Ta_{2/3})O_3$ ceramics prepared by solid-state reaction have been investigated. Adding $ZrO_2$ and NiO could effectively promote the densification even the case of decreasing the sintering time. At the surface of samples, secondary phase of Ba-Ta compounds was formed possibly due to the evaporation of ZnO, however, the interior of the samples remained as pure Ba$(Zn_{1/3}Ta_{2/3})O_3$. The samples sintered at $1600^{\circ}C$ for 2h exhibited 1:2 ordering of Zn and Ta cations. Excellent microwave dielectric properties of $Q{\cdot}f$(>96,000 GHz) and ${\varepsilon}_r$=30 has been obtained.

fMRI Study on the Brain Activity Induced by Manual Acpuncture at BL62 (신맥(申脈) 혈위자극이 fMRI상 뇌활성화 변화에 미치는 영향 연구)

  • Rheu, Kyoung-Hwan;Choi, Il-Hwan;Park, Hi-Joon;Lim, Sa-Bi-Na
    • Korean Journal of Acupuncture
    • /
    • v.23 no.2
    • /
    • pp.89-103
    • /
    • 2006
  • Objectives: Recently, the effect of acupuncture has been approved not only in the East but also in the West, so the interest on acupuncture was greatly improved. Especially, functional magnetic resonance imaging(fMRI) was embossed as the study tool for the mechanism of acupuncture noninvasively and many studies on the mechanism of acupuncture using fMRI were carried out. We archived the fMRI study on the brain activity induced by manual acupuncture at BL62(申脈). Methods: The study was the acupuncture at BL62(申脈) and we acquired 9 fMRI results from 6 persons$(age\;20{\sim}30,\;4\;male\;and\;2\;female)$. These studies employed The block design for mapping brain activity and acupuncture was perfomed at BL62(申脈) on the left foot. Results: The brain related motor function was cerebellum, basal ganglia and cerebral cortex and thalamus connected these elements. In the result of this study, the regions of significant activation in the cerebellum was centered on the spinocerebellum in the anterior lobe, so we presumed that this result showed the input of stimulation by the acupuncture on BL62(申脈). But basal ganglia and cerebral cortex showed the regions of significant activation in the left larger than the right and regions of the cerebral cortex was the motor and sensory cortex. Such a result explained that acupuncture at BL62(申脈) could have influence the motor function and acupuncture at left BL62(申脈) could affect the right side through the activation of the left basal ganglia and cerebral cortex. Conclusions: In the theory of crossing needling at collaterals(繆刺論), it the pathogenic factor invaded in the Yang Heel channel(陽?脈) that was one of the eight Extra meridians(奇經八脈), we recognized the disease of the collateral channel and used contralateral BL62(申脈) for treatment of the Yang Heel channel(陽?脈). Moreover the result of this study could bear the construction that acupuncture at the left BL62(申脈) treats the contralateral lesion and this construction is related to the theory of crossing needling at collaterals(繆刺論).

  • PDF

Electrochemical Properties of Molydenum (V) Complexes with Multidentate Ligands Containing Nitrogen or / and Oxygen Donor Atom (질소, 산소 주게원자 리간드를 가진 몰리브덴 (V) 착물의 전기화학적인 성질)

  • Sang Oh OH;Soo Gyun ROH
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.484-495
    • /
    • 1989
  • Reactions of $(Et_4N)_2[MoOCl_5]$ with multidentate ligands containing nitrogen or/and oxygen donor atom (EDTA, DTPA, IDA, CyDTA, OX) produce a series of binuclear molybdate (V) complexes. The prepared Mo (V) complexes has been identified by Elemental Analysis, Infrared Spectra, Proton Magnetic Resonance Spectra, and Electronic Spectra. The electrochemical reduction mechanism has been studied by Cyclic voltammetry, Controlled Potential Coulometry, and Spectrophotometry in pH 3.571-10.375 acetate, borate, phosphate/sodium hydroxide, phosphate, ammonium/ammonia buffers. The cyclic voltammogram of the Mo-EDTA, DTPA, IDA, CyDTA complexes at pH < ca. 6.00 have shown two reduction waves. The first reduction wave shows two electron process and the second reduction wave shows two electron process. The cyclic voltammogram of the Mo-EDTA, DTPA, IDA, CyDTA complexes at pH < ca. 8.00 has shown one reduction wave. This reduction wave show four electron process. The cyclic voltammogram of the Mo-OX complex at pH < ca. 7.2 has shown one reduction wave. This reduction wave show four electron process.

  • PDF

A Study on Discriminative Criteria of 6 Kinds of Achyranthis Radix Using HPLC/DAD;Isolation and Identification of 20-hydroxyecdysone from Aclryranthes japonica $N-{AKAI}$ and Comparison of Patterns of Achyranthis Radix from Different Locations by HPLC (HPLC/DAD를 이용한 6종(種) 우슬(牛膝)의 분류기준 연구;우슬(牛膝)(쇠무릎, Achyranthes japonica $N_{AKAI}$)로부터 20-hydroxyecdysone 분리.동정 및 산지별 우슬의 HPLC 패턴 비교)

  • Kim, Jeong-Hi;Kim, Jong-Mun;Kang, Dae-Hoon
    • The Korea Journal of Herbology
    • /
    • v.23 no.1
    • /
    • pp.109-116
    • /
    • 2008
  • Objectives : This study was performed to investigate the discriminative criteria of 6 kinds of Achyranthis Radix by HPLC/DAD. Methods : 20-hydroxyecdysone is isolated by silica gel column chromatography ($CHCl_3$:MeOH, 7:1-1:1 v/v) and identified by nuclear magnetic resonance, A high-performance liquid chromatographic method with diode array detection was used to identify 20-hydroxyecdysone in A. japonica. The analysis was performed using $C_{18}$ column with isocratic elution consisted of 18% acetonitrile and 82% water and the detection was carried out by DAD at 254 nm. 6 kinds of Achyranthis Radix from different locations were extracted in MeOH. Each extracts was analyzed by HPLC in same condition as used in analysis of 20-hydroxyecdysone. The identities of each extracts were determined by comparing the retention time and UV spectrum with that of reference compound. Results : 1. A. japonica and A. bidentata showed the similar patterns of HPLC chromatogram and 20-hydroxycedysone was present in both of them because the peaks having the same retention time and UV spectrum as 20-hydroxyecdysone were shown in the HPLC chromatograms of A. japonica and A. bidentata 2. Cyathula officinalis and C. capitata showed the similar patterns of HPLC chromatogram. The peak having the same retention time and UV spectrum as 20-hydroxyecdysone was shown in the HPLC chromatogram of C. capitata but not shown in the HPLC chromatogram of C. officinalis. 3. Two species of medicinal drugs from Sacheon province showed similar patterns of HPLC chromatogram. Achyranthis Radix from Sacheon(wild) did not have 20-hydroxycedysone but Achyranthis Radix from Sacheon(cultivated) showed the peak having the same retention time as 20-hydroxyecdysone but UV spectrum of the peak was different from that of 20-hydroxyecdysone. Conclusions : These results suggested that 20-hydroxyecdysone could be the discriminative criteria for Achyranthis Radix contain 20-hydroxyecdysone though they belong to different genus and species. And the patterns of HPLC chromatogram also could be the discriminative criteria as the different species of Achyranthis Radix belonging to the same genus showed similar patterns of HPLC chromatogram.

  • PDF

Percutaneous Radiofrequency ablation for the Treatment of Osteoid osteoma (유골골종의 경피적 고주파 열 치료)

  • Seo, Jai-Gon;Jung, Kwang-Hoon;Yang, Il-Soon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.3
    • /
    • pp.83-89
    • /
    • 2002
  • Purpose: To analyze the postoperative functional and radiographic follow-up results in patients who underwent percutaneous radiofrequency ablation therapy after the diagnosis of osteoid osteoma. Materials and Methods: Seven patients, who were clinically and radiographically diagnosed with osteoid osteoma from July 1999 to January 2001, and received percutaneous radiofrequency ablation therapy. The average follow-up period was 15.5 months(range, 8~25 months). For the diagnosis and accurate localization of the lesion, simple radiography, computed tomography and magnetic resonance imaging(MRI) were performed preoperatively. Simple radiographs and MRI were taken periodically for the follow-up studies. Results: In all 7 patients, symptoms completely disappeared within 3 days after the operation. The average period of hospitalization was 2.4 days, excluding 1 patient who needed an additional burn treatment. The average postoperative night and day pain scores were 1.8 and 1.3, respectively. The average vocational and recreational activity scores were 1 and 0.6, respectively. Conclusions: Satisfactory functional results were obtained with percutaneous radiofrequency ablation therapy for the elimination of osteoid osteoma. Compared to conventional treatment, the advantages of this therapy were short hospitalization period, no internal fixation and bone graft for preventing fracture, and no limitation of joint motion by long fixation period.

  • PDF

Design and Fabrication of Low Loss, High Power SP6T Switch Chips for Quad-Band Applications Using pHEMT Process (pHEMT 공정을 이용한 저손실, 고전력 4중 대역용 SP6T 스위치 칩의 설계 및 제작)

  • Kwon, Tae-Min;Park, Yong-Min;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.584-597
    • /
    • 2011
  • In this paper, low-loss and high-power RF SP6T switch chips are designed, fabricated and measured for GSM/EGSM/DCS/PCS applications using WIN Semiconductors 0.5 ${\mu}m$ pHEMT process. We utilized a combined configuration of series and series-shunt structures for optimized switch performance, and a common transistor structure on a receiver path for reducing chip area. The gate width and the number of stacked transistors are determined using ON/OFF input power level of the transceiver system. To improve the switch performance, feed-forward capacitors, shunt capacitors and parasitic FET inductance elimination due to resonance are actively used. The fabricated chip size is $1.2{\times}1.5\;mm^2$. S-parameter measurement shows an insertion loss of 0.5~1.2 dB and isolation of 28~36 dB. The fabricated SP6T switch chips can handle 4 W input power and suppress second and third harmonics by more than 75 dBc.

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.