• Title/Summary/Keyword: Resonance

Search Result 11,082, Processing Time 0.047 seconds

Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI (효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상)

  • Park, Ji Hee;Choi, Seon-Hyeong;Kim, Sungjun;Yong, Hwan Seok;Woo, Hyunsik;Jin, Kwang Nam;Jeong, Woo Kyoung;Shin, Na-Young;Choi, Moon Hyung;Jung, Seung Eun
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.254-258
    • /
    • 2018
  • Purpose: Establishment of an appropriate protocol for breast magnetic resonance imaging (MRI) in the study of image quality standards to enhance the effectiveness of medical image information exchange, which is part of the construction and activation of clinical information exchange for healthcare informatization. Materials and Methods: The recommended protocols of breast and MRI scans were reviewed and the questionnaire was prepared by a responsible researcher. Then, a panel of 9 breast dedicated radiologists was set up in Korea. The expert panel conducted a total of three Delphi agreements to draw up a consensus on the breast MRI protocol. Results: The agreed breast MRI recommendation protocol is a 1.5 Tesla or higher device that acquires images with prone position using a breast dedicated coil and includes T2-weighted and pre-contrast T1-weighted images. Contrast enhancement images are acquired at least two times, and include 60-120 seconds between images and after 4 minutes. The contrast enhancement T1-weighted image should be less than 3 mm in thickness, less than 120 seconds in temporal resolution, and less than $1.5mm^2$ in-plane pixel resolution. Conclusion: The Delphi agreement of the domestic breast imaging specialist group has established the recommendation protocol of the effective breast MRI.

Effect of Facet Tropism on the Degeneration of the Cervical Facet Joint and Intervertebral Disc (경추의 후관절 퇴행과 추간판 퇴행에서 후관절 비대칭성의 영향)

  • Chung, Sung Soo;Park, Chan-Ho;Heo, Ki Seong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.413-418
    • /
    • 2021
  • Purpose: To investigate the effect of facet tropism on the degeneration of facet joint and intervertebral disc in the cervical spine. Materials and Methods: From January 2017 to December 2018, cervical tropism of 100 patients at the C5/6 level was analyzed retrospectively. In computed tomography (CT), the orientation and tropism of the facet joint with respect to the sagittal, coronal, and horizontal planes were measured. Regression of the facet joint in magnetic resonance imaging (MRI) and CT was assessed using a grading system. Intervertebral disc degeneration was assessed and divided into five grades on MRI. For the left and right asymmetry, a difference between two facet angles of less than 7° was classified as the control group, more than 7° was classified as the tropism group. Results: The mean age of the patients was 55.44±12.3 years (31-81 years) in the tropism group and 55.66±10.7 years (32-76 years) in the control group. In the tropism group, 32 were male and 18 were female. In the control group, 24 were male and 26 were female. Facet joint degeneration was identified in 24 patients (48.0%) in the tropism group and 14 patients (28.0%) in the control group, showing a significant difference. Intervertebral disc degeneration was identified in 29 patients (58.0%) in the tropism group and 17 patients (34.0%) in the control group, showing a significant difference. Multivariate revealed, tropism to be a factor that affected the facet joint and intervertebral disc degeneration. Conclusion: Facet joint and intervertebral disc degeneration occurred significantly in the tropism group, and tropism is a factor affecting the degeneration of facet joint and intervertebral disc in the C5/6 level.

Risk Factor for Poor Clinical Outcome in Patients with Retear after Repair of the Rotator Cuff (회전근 개 파열 봉합술 후 재파열 환자에서 불량한 임상 결과의 원인 인자)

  • Lee, Hee Jae;Joo, Il Han;Hur, Jeong Min;Oh, Hyun Keun;Lee, Bong Gun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.61-67
    • /
    • 2021
  • Purpose: To evaluate the prognostic factors affecting poor functional outcomes in patients with retear after rotator cuff repair. Materials and Methods: From January 2013 to December 2018, among 631 patients who underwent arthroscopic repair of a rotator cuff tear, 42 patients, who could be followed-up for more than one year and showed a retear of the repaired cuff on magnetic resonance imaging (MRI), were collected retrospectively. The preoperative demographic data, range of motion, American Shoulder and Elbow Surgeons (ASES) score, fatty degeneration, and tear progression on postoperative MRI, as well as other factors that could affect the clinical outcomes, were analyzed. Patients who scored <80 points on the ASES score were allocated to the poor function group. The risk factors for poor clinical outcomes were compared with the group with ASES scores of 80 or above. Results: The postoperative functional results in the group with retear (n=42) after arthroscopic rotator cuff repair showed significant improvement. Univariate analysis revealed the preoperative visual analogue scale (VAS) score and tear progression to have associations with a poor shoulder function. In addition, subscapularis repair was found to be associated with a good shoulder function. The preoperative VAS score and tear progression except for subscapularis repair were independent factors associated with poor clinical outcomes according to multivariate logistic regression analysis. Conclusion: In patients with retear after rotator cuff repair, the preoperative VAS and tear progression in postoperative MRI are factors predicting a poor functional outcome.

Humeral Head Decentralization of Preoperative Magnetic Resonance Images and the Treatment of Shoulder Dislocations in Large to Massive Rotator Cuff Tears in Elderly over 65 Years Old (65세 이상 고령의 회전근 개 대파열 및 광범위 파열에 동반된 견관절 탈구의 치료 및 술 전 자기공명영상의 상완골두 탈중심화)

  • Lee, Bong-Ju;Song, In-Soo;Cha, Kihun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.418-426
    • /
    • 2019
  • Purpose: This study analyzed the features of humeral head decentralization in large to massive rotator cuff tears with a shoulder dislocation in the elderly. Moreover, shoulder instability and treatment were reviewed. Materials and Methods: From May 2005 to February 2017, Group A containing 45 cases (45 patients) over 65 years old accompanied by a large or massive rotator cuff tear with a shoulder dislocation and Group B containing 45 cases (45 patients) without a shoulder dislocation were enrolled. The mean ages in Groups A and B were 73.2 and 72.1 years old, and the mean follow-up periods were 30.7 and 31.3 months, respectively. Twenty-one cases (46.7%) in Group A underwent rotator cuff repair, and 8 cases (17.8%) underwent concomitant rotator cuff repair with Bankart repair. Sixteen cases (35.6%) underwent reverse total shoulder arthroplasty for cuff tear arthropathy. 45 cases (100%) in Group B underwent rotator cuff repair. The off-the center and head elevation were measured in the preoperative magnetic resonance imaging (MRI) of Groups A and B. The preoperative and postoperative visual analogue scale (VAS) score, American Shoulder and Elbow Surgeons (ASES) score, and University of California Los Angeles (UCLA) score in Groups A and B were compared. Results: In Groups A and B, the mean off-the centers were posterior 7.41 mm and posterior 2.02 mm (p=0.03), and the mean head elevations were superior 6.66 mm and superior 2.44 mm (p=0.02), respectively. The mean ASES scores of Groups A and B were 32.8 and 33.4 before surgery, and 77.1 (p=0.02) and 78.1 (p=0.02) after surgery (p=0.18), respectively. The mean UCLA scores of Groups A and B were 13.1 and 12.8 before surgery, and 28.9 (p=0.02) and 29.5 (p=0.01) after surgery (p=0.15), respectively. Conclusion: Patients over 65 years old with a shoulder dislocation in large to massive rotator cuff tears had higher off-the center and head elevation on the preoperative MRI than those without a shoulder dislocation. This measurement can help predict preceding shoulder instability. Early rotator cuff repairs should be performed and other treatments, such as Bankart repair and reverse total shoulder arthroplasty, should also be considered.

The Diagnostic Accordance between Transcranial Doppler and MR Angiography in the Intracranial Artery Stenosis (두개강내 혈관 협착에 대한 경두개도플러와 자기공명 혈관조영술의 일치도 평가)

  • Moon, Sang-kwan;Jung, Woo-sang;Park, Sung-uk;Park, Jung-mee;Ko, Chang-nam;Cho, Ki-ho;Bae, Hyung-sup;Kim, Young-suk;Cho, Seong-il
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.7 no.1
    • /
    • pp.11-16
    • /
    • 2006
  • Objectives : Transcranial Doppler (TCD) has been reported to be established as useful in detecting spasm after subarachnoid hemorrhage and to be probably useful in diagnosing stenosis or occlusion in intracranial arteries. In the detection of intracranial stenosis using TCD there have been reported some kinds of diagnostic criteria. This study was aimed to evaluate the accordance between TCD and magnetic resonance angiography (MRA) in detection of intracranial stenosis and to find out more accurate criteria for intracranial stenosis using TCD. Methods : Seventy-six stroke patients were evaluated by TCD and MRA. TCD criteria for middle cerebral artery (MCA) stenosis were used by 3 methods; ≥ 80cm/sec of mean velocity(Vm), ≥ 140 cm/sec of systolic velocity(Vs), and both. For stenosis of vertebral(VA) and basilar arteries(BA), the TCD criteria followed by 2 methods; ≥ 70 cm/sec of Vm and ≥ 100 cm/sec of Vs. The stenosis of intracranial artery in MRA followed by the interpretation of specialist in the department of radiology. The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and kappa agreement were calculated in each criteria of TCD compared with the result of MRA. Results : The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and kappa agreement using ≥ 80cm/sec of Vm for MCA stenosis were 55.6%, 81%, 34.5%, 91.0%, 77.1%, and 0.293, respectively. Using 140 cm/sec of Vs, those were 44.4%, 92.0%, 50.5%, 90.2%, 84.7%, 0.380, and using both criteria those were 44.4%, 95.0%, 61.5%, 90.5%, 87.3%, 0.445, respectively. Those using ≥ 70 cm/sec of Vm for VA and BA stenosis were 71.4%, 93.7%, 26.3%, 99.0%, 93.0%, 0.186 and using ≥ 100 cm/sec of Vs those were 71.4%, 97.3%, 45.5%, 99.1%, 96.5%, 0.539, respectively. Conclusion : These results suggested that for the diagnosis of MCA stenosis using TCD we should use the criteria of both ≥ 80cm/sec of Vm and 140 cm/sec of Vs, and for the VA and BA stenosis we adapt the criteria of ≥ 70 cm/sec of Vm.

  • PDF

A Study on The Measurement of Cerebral Cortical Thickness in Patients with Mood Disorders (기분장애 환자의 대뇌 피질 두께 측정에 관한 연구)

  • Do-Hun Kim;Hyo-Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2024
  • This study compared the cortical thickness of patients with mood disorders and a control group to assess structural abnormalities. A retrospective study was conducted from September 2020 to August 2022 at the Department of Psychiatry, P Hospital in Yangsan, Gyeongsangnam-do. The study included 44 individuals diagnosed with mood disorders and 59 healthy individuals without any pathological lesions. The 3D-T1 MPRAGE images obtained from magnetic resonance imaging examinations were utilized, and FreeSurfer software was employed to measure cortical thickness. Statistical analysis involved independent samples t-tests to measure the differences in means between the two groups, and Cohen's d test was used to compare the effect sizes of the differences. Furthermore, the correlation between the measured average cortical thickness and Positive and Negative Syndrome Scale scores was analyzed. The research results revealed that patients with mood disorders exhibited decreased cortical thickness compared to the normal control group in both superior frontal regions, both rostral middle frontal regions, both caudal middle frontal regions, both pars opercularis, pars orbitals, pars triangularis regions, both superior temporal regions, both inferior temporal regions, both lateral orbitofrontal regions, both medial orbitofrontal regions, both fusiform regions, both posterior cingulate regions, both isthmus cingulate regions, both superior parietal regions, both inferior parietal regions, both supramarginal regions, left postcentral region, right bank of the superior temporal sulcus region, right middle temporal region, right rostral anterior cingulate region, and right insula region. Among them, regions that showed differences with effect sizes of 0.8 or higher were left fusiform (d=0.82), pars opercularis (d=0.94), superior frontal (d=0.88), right lateral orbitofrontal (d=0.85), and pars orbitalis (d=0.89). Additionally, there was a weak negative correlation between PANSS scores and average cortical thickness in both the left hemisphere (r=-0.234) and right hemisphere (r=-0.230). These findings are expected to be helpful in identifying areas of cortical thickness reduction in patients with mood disorders compared to healthy individuals and understanding the relationship between symptom severity and cortical thickness changes.

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

The Magnetic Relaxation Properties of DTPA-bis(4-carboxycyclohexyl) amide Paramagnetic Gd-chelates (DTPA-bis(4-carboxycyclohexyl)amide 상자성 복합체의 자기이완특성에 관한 연구)

  • Kim, In-Sung;Lee, Young-Ju;Lee, Jae-Jun;Kim, Ju-Hyun;Kim, Yoo-Kyung;Sujit, Dutta;Kim, Suk-Kyung;Kim, Tae-Jeong;Kang, Duk-Sik;Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • Purpose : To evaluate the NMR relaxation properties of newly developed high performance paramagnetic complexes. Materials and methods : 4-aminomethylcyclohexane carboxylic acid (0.63g, 4 mmol) was mixed with the suspension solution of DMF (15mL) and DTPA-bis-anhydride (0.71g, 2 mmol) to synthesize the ligand. The ligand was then mixed with Gd2O3 (0.18g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1mM and then the relaxation times were measured at 1.5T(64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG(Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. Using MATLAB(Version 7.1) program, T1 magnetic relaxation map, R1 map, T2 magnetic relaxation map and R2 map were developed to represent magnetic relaxation time and magnetic relaxivity as image. Results : Compared to $R1=4.9mM^{-1}sec^{-1}$ and $R2=4.8mM^{-1}sec^{-1}$ of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, R1 of SUK090(Gd-C32H74N5O24) was $12.46mM^{-1}sec^{-1}$ and R1 of SUK091(Gd-C34H78N5O24) was $12.77mM^{-1}sec^{-1}$. However, R1 of SUK092(Gd-C30H56N5O17) was decreased to $2.09mM^{-1}sec^{-1}$. In case of R2, SUK090(Gd-C32H74N5O24) was $8.76mM^{-1}sec^{-1}$ and SUK091(Gd-C34H78N5O24) was $7.60mM^{-}1sec^{-1}$ whereas SUK092(Gd-C30H56N5O17) was decreased to $1.82mM^{-1}sec^{-1}$. Conclusion : Among three new paramagnetic complexes, SUK090(Gd-C32H74N5O24) and SUK091(Gd-C34H78N5O24) showed higher T1, T2 magnetic relaxation rates than that of commercially available paramagnetic MR agent and thus expected to have more contrast enhancement effect.

  • PDF