• Title/Summary/Keyword: Resolution phantom

Search Result 287, Processing Time 0.037 seconds

Numerical Study on the Sub-Voxel Tracking Using Micro-Beads in a 3.0 T MRI (3.0 T MRI 환경에서 마이크로비드를 이용한 서브복셀 추적에 관한 수치해석적 연구)

  • Han, Byung-Hee;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.102-107
    • /
    • 2007
  • In molecular imaging studies via magnetic resonance imaging, in vivo cell tracking is an important issue for the observation of cell therapy or disease behavior. High resolution imaging and longitudinal study are necessary to track the cell movement. Since the field inhomogeneity extends over several voxels, we have performed the numerical analysis using the sub-voxel method dividing a voxel of MR image into several elements and the information about the field inhomogeneity distribution around the micro-beads. We imbedded ferrite-composite micro-beads with the size of $20-150{\mu}m$ in the subject substituted for cells to induce local field distortion. In the phantom imaging with the isotropic voxel size of $200{\mu}m^3$, we could confirm the feasibility of sub-voxel tracking in a 3.0 T MRI.

Implementation of Multi-Streaming System of Live Video of Drone (드론 라이브 영상의 다중 스트리밍 시스템 구현)

  • Hwang, Kitae;Kim, Jina;Choi, Yongseok;Kim, Joonhee;Kim, Hyungmin;Jung, Inhwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.143-149
    • /
    • 2018
  • This paper presents an implementation of a streaming system which can forward live video stream to multiple users from a Phantom4, which is a drone made by DJI. We constructed the streaming server on Raspberry Pi 3 board for high mobility. Also We implemented the system so that the video stream can be played on any devices if the HTML5 standard web browser is utilized. We compiled C codes of FFmpeg open sources and installed in the Raspberry Pi3 as the streaming server and developed a Java application to execute as the integrated server that controls the other softwares on the streaming server. Also we developed an Android application which receives the live video stream from the drone and sends the streaming server continuously. The implemented system in this paper can successfully stream the live video on 24 frames per second at the resolution of 148x112 in considering the low hardware throughput of the streaming server.

Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table (전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가)

  • Jeon, Sang-Won;Pak, Jae-Yun;Suh, Tae-Suk
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.819-825
    • /
    • 2020
  • The purpose of this study was to evaluate the usefulness of the developed air mattress for reducing the deterioration of image quality due to the scattered radiation generated on the computed tomography equipment table. 5 cm and 10 cm thick air mattresses were developed and the image quality was measured by scanning the AAPM phantom according to thickness and thickness. Statistical significance was confirmed by One Way Analysis of Variance(ANOVA) Compared with the AAPM phantom scanned in the standard method, the image with the air mattress did not show any difference, but when the air mattress was not applied, the CT number and uniformity were low and the noise was high, and the spatial resolution Respectively. The developed air mattress has no harmful effect on the diagnostic image, it is very effective in improving the image quality and can increase the CT image quality by simply applying Air Mattress to existing equipment without using the technology applied to the latest and high-cost equipment.

Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave (탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.119-129
    • /
    • 2012
  • In the medical field, the hardening of tissues is one of important informations used in diagnosis or understanding progress of disease, a quantitative measuring method of hardening is important for objective diagnosis. It has been proposed MRE(Magnetic Resonance Elastography) method that measures an index of hardening, viscoelastic properties in a noninvasive. Because the S/N ratio of MRE images go down when measuring viscoelastic properties from local wavelength and local damping factor of a propagating wave in MRE method, methods using multiple phase MRE images have been examined to decrease the effect of noise. We propose a method measuring viscoelastic properties after Fitting a function for multiple phase MRE images in this research. This proposed method has a advantage to set up arbitrarily the variation rate of a space direction of viscoelastic properties or the spatial resolution of measuring values according to changing of the noise included in images, though it applies viscoelastic wave for multiple phase MRE images. We confirmed the effectiveness of a proposed method by experiment using simulation images and experiment using silicone-gel phantom.

Hand-Held Mobile Phone Design for SAR Reduction (SAR 저감을 위한 휴대폰 설계)

  • 홍수원;오학태;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.352-359
    • /
    • 2001
  • We propose the row method that is able to consider the SAR compliance test from the very beginning step of developing the mobile phone. The reason this new method is plausible is that we adopt the certified FDTD for the reliability of calculation, utilizing 1 mm high resolution model that is to model the phantom and the mobile phone almost identically to the reality. In this paper we introduce the process that will apply the proposed method in order to reduce the SAR of the mobile phone that has been problematic in satisfying the SAR compliance test. It results in dropping in the SAR that we keep the mobile phone or its antenna while we use it. Therefore here we make a claim as fellows. When we develop the new mobile phone, we should use the computer simulation combining the CAD design and radiation pattern rather than make a prototype and then use the trial and error method. Moreover the former way leads us to boost up the developing efficiency and reduce the cost.

  • PDF

A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation (치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구)

  • Lee, Dong-Hun;Kwon, Jang-Woo;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.11-20
    • /
    • 1996
  • In this paper, the characteristics of therapy radiation diode sensors have been studied by using therapy radiation from the MM22 microtron accelerator. The linearity, reproducibility and error ratio were measured for feasibility as a radiation detector. Energy dependence, sensitivity change after a amount of irradiation and output value according to a number of diodes were also measured for same purpose. We have formed pulse shaping of diode signal with nuclear instruments for portal image reconstruction. The percent depth dose ratio according to field size and depth was compared with that of the detector of a ion chamber. Using thirteen silicon diodes, we can directly read diode outputs on a computer monitor after A/D conversion with 16 channels analog to digital conversion board with 12 bit resolution. The possibility for portal image with diodes has been suggested from output comparison between output value with a human phantom and that without a human phantom.

  • PDF

A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence (인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구)

  • Yeon Jin, Im;Ho Seong, Hwang;Dong Hyun, Kim;Ho Chul, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF