• Title/Summary/Keyword: Resolution Matrix

Search Result 357, Processing Time 0.027 seconds

A Novel Voltage-Programming Pixel with Current-Correction Method for Large-Size and High-Resolution AMOLEDs on Poly-Si Backplane

  • In, Hai-Jung;Bae, Joon-Ho;Kang, Jin-Sung;Kwon, Oh-Kyong;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.901-904
    • /
    • 2005
  • A novel active matrix organic light diodes (AMOLEDs) voltage-programming pixel structure with current-correction method is proposed for largesize and high-resolution poly-Si AMOLED panel applications. The HSPICE simulation results shows that the maximum error of emission current in proposed pixel is 1.536%, 2.45%, and 2.97% with the ${\pm}12.5%$ mobility variation and ${\pm}0.3V$ threshold voltage variation for 30-, 40-, and 50-inch HDTV panels, respectively.

  • PDF

Development of angiographic PIV and performance evaluation (Angiographic PIV기법 개발 및 성능 평가)

  • Jung, Sung-Yong;Kim, Guk-Bae;Lim, Nam-Yun;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.683-686
    • /
    • 2008
  • To diagnose vascular diseases from the viewpoint of hemodynamics, detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond were required. For investigating the hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique consisted of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulse-type X-ray source, and a synchronizer. Through several preliminary tests, the feasibility of the angiographic PIV technique was verified. For in-vivo measurements to real blood flows, we developed tracer microcapsules which were optimized to this system by encapsulating a contrast material of iodine with a matrix material of PVA (polyvinylpyrrolidone). In near future, the angiographic PIV technique would be useful for diagnosing hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

$ fractional factorial designs of resolution V and taguchi method

  • 김상익
    • The Korean Journal of Applied Statistics
    • /
    • v.5 no.1
    • /
    • pp.19-28
    • /
    • 1992
  • In this paper, minimal balanced $2^t$ fractional factorial designs which permit the estimation of main effects and 2-factor interactions are developed by using a partially balanced array. Such designs are characterized by a minimum number of runs and some balancedness property of the variance-covariance matrix of the estimates. In addition to describing the designs, optimality criteria are discussed and the trace-optimal designs are presented. The proposed designs are especially useful in Taguchi method, where we need to investigate up to 2-factor interactions of the control factors.

  • PDF

A Comparative Study on Discharge Characteristics of FHD and QFHD AC PDP (FHD와 QFHD 해상도를 가지는 AC PDP의 방전특성 비교연구)

  • Choi, Yong-Suk;Heo, Jun;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.119-123
    • /
    • 2011
  • We have investigated the luminous efficiency of various cell resolution and structure from 50" FHD to 50" QFHD Plasma Display. The suggested test panels have two different cell array types which are the delta and matrix cell array type. The results showed that, in the case of the suggested QFHDs, the firing and sustain voltage were increased and voltage margin was decreased. These results are caused by the reduced wall voltage and increased charged particle loss, at the side wall. The luminance of the suggested QFHDs was lower from 20% to 40% than that of the suggested FHDs and the power consumption was higher from 42% to 83% than that of the suggested FHDs. In conclusion, the maximum luminous efficiency of the suggested QFHD(D110) has reached about 38%, compared with suggested FHDs($\fallingdotseq$ 2.7 lm/W).

Feature Based Multi-Resolution Registration of Blurred Images for Image Mosaic

  • Fang, Xianyong;Luo, Bin;He, Biao;Wu, Hao
    • International Journal of CAD/CAM
    • /
    • v.9 no.1
    • /
    • pp.37-46
    • /
    • 2010
  • Existing methods for the registration of blurred images are efficient for the artificially blurred images or a planar registration, but not suitable for the naturally blurred images existing in the real image mosaic process. In this paper, we attempt to resolve this problem and propose a method for a distortion-free stitching of naturally blurred images for image mosaic. It adopts a multi-resolution and robust feature based inter-layer mosaic together. In each layer, Harris corner detector is chosen to effectively detect features and RANSAC is used to find reliable matches for further calibration as well as an initial homography as the initial motion of next layer. Simplex and subspace trust region methods are used consequently to estimate the stable focal length and rotation matrix through the transformation property of feature matches. In order to stitch multiple images together, an iterative registration strategy is also adopted to estimate the focal length of each image. Experimental results demonstrate the performance of the proposed method.

Direction-of-Arrival Estimation : Signal Eigenvector Method(SEM) (도래각 추정 : 신호 고유벡터 알고리즘)

  • 김영수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.12
    • /
    • pp.2303-2312
    • /
    • 1994
  • A high resolution algorithm is presented for resolving multiple narrowband plane waves that are incident on an equispaced linear array. To overcome the deleterious effects due to coherent sources, a number of noise-eigenvector-based approaches have been proposed for narrowband signal processing. For differing reasons, each f these methods provide a less than satisfactory resolution of the coherency problem. The proposed algorithm makes use of fundamental property possessed by those eigenvectors of the spatial covariance matrix that are associated with eigenvalues that are larger than the sensor noise level. This property is then used to solve the incoherent and coherent sources incident on an equispaced linear array. Simulation results are shown to illustrate the high resolution performance achieved with this new approach relative to that obtained with MUSIC and spatial smoothed MUSIC.

  • PDF

A Study on Power Spectrum Algorithm for Signal Resolution Improvement (신호 분해능 향상을 위한 전력스펙트럼 알고리즘 연구)

  • Lee, Kwan-Hyeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.2
    • /
    • pp.153-158
    • /
    • 2020
  • In this paper, we studied an algorithm for estimating a desired target by removing noise and interference in a wireless communication environment. When an information signal with a mixture noise and interference receive a receiver, noise and interference signals must be removed to accurately estimate a desired target. In order to divide the received signal region into two spatial, a power spectrum is obtained by analyzing a correlation matrix, covariance, eigen vector, and eigen value. The proposed spectrum is an algorithm that can remove noise and interference, and analyzes the existing algorithm and target estimation performance through simulation. As a result of simulation, the target estimation resolution of existing algorithm is more than 10°, but the resolution of the proposed algorithm is less than 10°. The proposed algorithm has improved the resolution of about 5° than the exiting algorithm. The proposed algorithm proved that the target estimation accuracy and resolution are superior to the existing algorithm.

Raw Sensor Single Image Super Resolution Using Color Corrector-Attention Network (코렉터 어텐션 네트워크을 이용한 로우 센서 영상 초해상화 기법)

  • Paul Shin;Teaha Kim;Yeejin Lee
    • Journal of Broadcast Engineering
    • /
    • v.28 no.1
    • /
    • pp.90-99
    • /
    • 2023
  • In this paper, we propose a super resolution network for raw sensor image which data size is lower comparatively to RGB image. But the actual capabilities of raw image super resolution depends on color correction because its absent of camera post processing that leads to unintended result having different white balance, saturation, etc. Thus, we introduce novel color corrector attention network by adopting the idea of precedent raw super resolution research, and tune to the our faced problem from data specification. The result is not superior to former researches but shows decent output on certain performance matrix. In the same time, we encounter new challenging problem of unexpected shadowing artifact around image objects that cause performance declination despite its good result overall. This problem remains a task to be solved in the future research.

Construction of an Improved Tandem Time-of-flight Mass Spectrometer for Photodissociation of Ions Generated by Matrix-assisted Laser Desorption Ionization (MALDI)

  • Moon, Jeong-Hee;Yoon, So-Hee;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.763-768
    • /
    • 2005
  • An improved tandem time-of-flight (TOF) mass spectrometer for the photodissociation (PD) study of ions generated by matrix-assisted laser desorption ionization (MALDI), MALDI-TOF-PD-TOF, has been designed and constructed. Recording a full spectrum with better than unit mass resolution even in low mass range has been achieved without reflectron voltage stepping which was needed in the previous version. Other aspects of the improvement, such as those in the data system which now allow 10-100 times faster spectral acquisition than with the previous instrument, are described. Rationale for the ideas which have led to the improvements is presented also.

Multigrid Wavelet-Based Natural Pixel Method for Image Reconstruction in Emission Computed Tomography

  • Chang je park;Park, Jeong hwan;Cho, Nam-Zin
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.705-710
    • /
    • 1998
  • We describe a multigrid wavelet-based natural pixel (WNP) method for image reconstruction in emission computed tomography (ECT). The ECT is used to identify the tagged radioactive material's position in the body for detection of abnormal tissue such as tumor or cancer, as in SPECT and PET. With ECT methodology in parallel beam mode, we formulate a matrix-based reconstruction method for radionuclide sources in the human body. The resulting matrix for a practical problem is very large and nearly singular. To overcome this ill-conditioning, wavelet transform is considered in this study. Wavelets have inherent de-noising and multiscale resolution properties. Therefore, the multigrid wavelet-based natural pixel (WNP) method is very efficient to reconstruct image from projection data that is noisy and incomplete. We test this multigrid wavelet natural pixel (WNP) reconstruction method with the MCNP generated projection data for diagnosis of the simulated cancerous tumor.

  • PDF