• 제목/요약/키워드: Resisting strength

검색결과 408건 처리시간 0.033초

Cyclic test for beam-to-column abnormal joints in steel moment-resisting frames

  • Liu, Zu Q.;Xue, Jian Y.;Peng, Xiu N.;Gao, Liang
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1177-1195
    • /
    • 2015
  • Six specimens are tested to investigate the cyclic behavior of beam-to-column abnormal joints in steel moment-resisting frames, which are designed according to the principle of strong-member and weak-panel zone. Key parameters include the axial compression ratio of column and the section depth ratio of beams. Experimental results indicate that four types of failure patterns occurred during the loading process. The $P-{\Delta}$ hysteretic loops are stable and plentiful, but have different changing tendency at the positive and negative direction in the later of loading process due to mechanical behaviors of specimens. The ultimate strength tends to increase with the decrease of the section depth ratio of beams, but it is not apparent relationship to the axial compression ratio of column, which is less than 0.5. The top panel zone has good deformation capacity and the shear rotation can reach to 0.04 rad. The top panel zone and the bottom panel zone don't work as a whole. Based on the experimental results, the equation for shear strength of the abnormal joint panel zone is established by considering the restriction of the bottom panel zone to the top panel zone, which is suitable for the abnormal joint of H-shaped or box column and beams with different depths.

CFT 기둥-H형강보 엔드플레이트 접합부의 보-패널존 강도비에 따른 내진성능 평가 (Evaluation of Seismic Performance in Relation to Beam-Panel Zone Strength Ratio of CFT Column to H-beam Endplate Connections)

  • 김영주;김재건;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권6호
    • /
    • pp.769-777
    • /
    • 2000
  • 본 논문은 CFT기둥-H형강보 철골 모멘트 접합부의 보-패널존 강도비에 의한 내진거동을 평가하였다. 보에 대한 패널존의 상대강도를 주요변수로 하였다. 각 실험체는 $H-350{\times}175{\times}7{\times}11$ 보(SS400)와 ${\boxe}-250{\times}250{\times}9$, ${\boxe}-250{\times}250{\times}12$ 기둥(SPSR400)으로 제작되었다. 실험체의 에너지 흡수량은 5.2~12.7(tm)의 분포를 나타냈다. 패널존이 보에 비해 너무 강하거나 약하면, 에너지 흡수능력이 열등했다. 철골 모멘트 저항골조에 있어서 본 실험의 결과는 패널존의 항복을 허용하는 것이 내진거동에 유리함을 나타내고 있다.

  • PDF

철근콘크리트 기둥에서 원형전단철근에 의한 전단강도 산정 (Evaluation of the Shear Strength Component by Circular Transverse Reinforcement in Reinforced Concrete Columns)

  • 하태훈;홍성걸
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.982-988
    • /
    • 2002
  • 철근콘크리트 기둥에서 원형 전단철근에 의한 전단강도 성분을 산정하는 기존의 기준식들은 일반적으로 그 강도를 과대평가하는 경향이 있다. 그 이유는 불연속분포로 이루어진 철근의 배근을 단순한 연속분포로 가정하는 데에서 기인하며, 또 다른 한편으로는 단면이 직사각형인 부재에 사용되는 설계식을 원형 단면에 그대로 적용함으로써 발생한다. 전단철근은 부재에 대각선균열이 발생하면서 그 역할이 시작된다고 할 수 있는데, 원형 단면은 직사각형 단면과는 달리 균열을 가로지르는 지점에 따라 전단력에 저항하는 성분이 달라지기 때문이다. 본 연구에서는 원형 전단철근에 대하여 대각선 균열의 시작점과 그 균열을 가로지르는 전단철근의 개수, 그리고 원형단면 상에서의 저항성분의 변화를 고려한 새로운 강도모델을 제안하고자 하였다. 제안된 모델의 수학적인 해석에 따르면 균열을 가로지르는 철근의 개수가 적을수록 균열의 시작점 및 균열의 수직투영거리가 철근의 배근 간격과 이루는 배율이 철근의 전단저항에 미치는 영향이 크다는 사실을 알 수 있었다. 본 연구의 결과로 도출된 불연속 모델을 설계에 이용될 수 있는 식으로 단순화시키기 위해 선형회귀법이 이용되었으며, 이렇게 유도된 설계방정식은 수학적 정해의 하한계 값에 부합하는 결과를 가져왔다.

Effect of anchorage and strength of stirrups on shear behavior of high-strength concrete beams

  • Yang, Jun-Mo;Min, Kyung-Hwan;Yoon, Young-Soo
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.407-420
    • /
    • 2012
  • This study investigated possible ways to replace conventional stirrups used on high-strength concrete members with improved reinforcing materials. Headed bar and high-strength steel were chosen to substitute for conventional stirrups, and an experimental comparison between the shear behavior of high-strength concrete large beams reinforced with conventional stirrups and the chosen stirrup substitutes was made. Test results indicated that the headed bar and the high-strength steel led to a significant reserve of shear strength and a good redistribution of shear between stirrups after shear cracking. This is due to the headed bar providing excellent end anchorage and the high-strength steel successfully resisting higher and sudden shear transmission from the concrete to the shear reinforcement. Experimental results presented in this paper were also compared with various prediction models for shear strength of concrete members.

Seismic evaluation of vertically irregular building frames with stiffness, strength, combined-stiffness-and-strength and mass irregularities

  • Nezhad, Moosa Ebrahimi;Poursha, Mehdi
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.353-373
    • /
    • 2015
  • In this paper, the effects of different types of irregularity along the height on the seismic responses of moment resisting frames are investigated using nonlinear dynamic analysis. Furthermore, the applicability of consecutive modal pushover (CMP) procedure for computing the seismic demands of vertically irregular frames is studied and the advantages and limitations of the procedure are elaborated. For this purpose, a special moment resisting steel frame of 10-storey height was selected as reference regular frame for which the effect of higher modes is important. Forty vertically irregular frames with stiffness, strength, combined-stiffness-and-strength and mass irregularities are created by applying two modification factors (MF=2 and 4) in four different locations along the height of the reference frame. Seismic demands of irregular frames are computed by using the nonlinear response history analysis (NL-RHA) and CMP procedure. Modal pushover analysis (MPA) method is also carried out for the sake of comparison. The effect of different types of irregularity along the height on the seismic demands of vertically irregular frames is investigated by studying the results obtained from the NL-RHA. To demonstrate the accuracy of the enhanced pushover analysis methods, the results derived from the CMP and MPA are compared with those obtained by benchmark solution, i.e., NL-RHA. The results show that the CMP and MPA methods can accurately compute the seismic demands of vertically irregular buildings. The methods may be, however, less accurate especially in estimating plastic hinge rotations for weak or weak-and-soft top and middle storeys of vertically irregular frames.

용융금속 프로브용 규조토 내열보호관의 제조 및 특성연구 (Study on Characteristics and Manufacture of Heat-Resisting Diatomite Protection Tube for Probe Used in Steelmaking Process)

  • 이만업;정학재;이교운
    • 한국세라믹학회지
    • /
    • 제42권4호
    • /
    • pp.260-268
    • /
    • 2005
  • 규조토를 주원료로 사용한 서로 다른 조성비의 세라믹 슬러리를 압출성형하여 내열보호관을 제조하고, 기계적 강도, 미세구조, 탄소분석을 하였다. 입도가 $50\~100\;{\mu}m$ 다공성 규조토를 $60wt\%$로 고정하고, 조성물 변수로써 유$\cdot$무기바인더로 silica sol$(4.3\~7.3\;wt\%)$, CMC(Sodium CarboxyMethyl Cellulose $(6\~9\;wt\%)$) 및 paper powder$(4.7\~7.7\;wt\%)$$1\;wt\%$씩 변화시켜 최적의 배합비를 얻었다. 시편의 특성을 조사한 결과, 규조토 $60\;wt\%$에 silica sol $5.3\;wt\%$, CMC $7\;wt\%$를 첨가하였을 경우, 꺽임강도 7.12 MPa, 탄성율 1090 MPa, 압축강도 1.47 MPa, 탄소 $2.3\;wt\%$ 이하로 철강산업에서의 온도$\cdot$성분측정 및 sample 채취를 할 수 있는 용융금속 프로브용 규조토 내열보호관을 제조할 수 있었다.

내부 구속 중공 CFT 기둥의 내화 성능에 대한 해석 연구 (Analytical Study on the Fire Resistance of Internally Confined Hollow CFT Column)

  • 원덕희;한택희;박종섭;강영종
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.461-470
    • /
    • 2009
  • 기둥은 축하중과 지진하중에 저항하는 주부재로서 구조물에서 가장 중요한 부재중의 하나이다. 이러한 기둥은 화재 시 고온에 의해 그 성능이 저하되어 전체 구조물계에 심각한 균열을 초래할 수 있으며, 구조물의 붕괴로도 이어질 수 있다. 본 연구에서는 새로운 형식의 기둥인 내부구속 중공 콘크리트 충전강관 기둥 (ICH CFT column; Internally Confined Hollow Concrete Filled Tube column)의 내화 성능이 연구되어져 있지 않기 때문에 건축물에 적용을 하여 기준에 맞는 기둥을 만들기 위해서는 내화 성능 평가가 필요하다. 본 기둥은 콘크리트 충전 강관 기둥 (CFT column; Concrete Filled Tube column)과 같이 외부 강관에 의해 콘크리트가 구속되어 기둥의 성능을 발휘하므로, 외부 강관의 항복 여부가 전체 기둥의 강도를 결정하게 될 것이다. 그래서 본 연구에서는 화재에 의한 기둥의 온도 변화에 따른 ICH CFT 기둥의 강도를 콘크리트의 구속효과와 재료비선형성을 고려하여 해석을 수행하였고, 또한 기둥의 중공비, 외부강관의 두께, 콘크리트의 강도를 매개 변수로 선정하여 기둥의 내화 성능을 평가하였으며, 해석에는 범용 프로그램과 전용 프로그램을 병행하여 사용하였다.

주인장 철근을 가진 HPFRCC 보 부재 전단 강도 예측 모델 (Shear Strength Model for HPFRCC Beams with Main Longitudinal Tensile Reinforcements)

  • 이성철;신경준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.60-67
    • /
    • 2020
  • 최근 HPFRCC의 구조 거동에 대한 연구가 많이 이루어져 왔으나, 휨 거동에 대한 연구가 주로 수행된 반면, 전단 거동에 대한 연구는 많이 부족한 상황이다. 이 연구에서는 전단 철근이 없는 HPFRCC 보 부재의 전단 강도를 합리적으로 예측할 수 있는 모델을 개발하였다. 모델을 개발하기 위해 HPFRCC 보 부재를 휨 모멘트에 저항하는 상·하현재와 전단력에 저항하는 복부 전단 요소로 간단히 이상화하였다. 이후 HPFRCC의 인장 거동 특성을 바탕으로 전단 파괴 시 복부 전단 요소의 주압축대 기울기 및 전단 응력을 산정하였으며, 이로부터 HPFRCC 보부재의 전단 강도를 산정할 수 있는 모델을 제안하였다. 제안 모델의 검증을 위해 기존의 전단 파괴된 48개의 HPFRCC 보 부재의 실험 결과와 비교하였다. 실험과 비교한 결과, 제안 모델이 실제 전단 강도를 평균 1.045, 변동계수 0.125로서 상당히 합리적으로 예측하는 것으로 나타났다. 이 연구의 주요 내용은 향후 HPFRCC가 적용되는 부재 또는 구조물에 대한 관련 연구 및 설계에 유용할 것으로 기대된다.

화재 피해를 입은 일반강도 및 고강도 RC 휨 부재의 잔존강도 평가 (Evaluation of Residual Strength of Fire-Damaged RC Beams with Normal and High Strength)

  • 최은규;강지연;신미경;신영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.51-54
    • /
    • 2005
  • Reinforced Concrete structures have been commonly regarded as fire-resisting constructions. In the case of high-strength concrete, however, the behavior of a concrete member under fire and after fire has characteristics in different way with normal strength concrete members because of spalling. The resonable evaluation about the residual strength and stiffness of members as well as material properties has to be conducted before reusing the fire-damaged structures or retrofitting or strengthening them. Therefore, the guideline is needed for evaluation the residual strength and stiffness. In this study, the fire test is conducted with parameters like concrete strength, fire time and cover thickness, etc. The loads-deflection curves are used for comparison and analysis with the parameters.

  • PDF

철근콘크리트 기둥의 전단강도 모델 (Shear Strength Model of Reinforced Concrete Columns)

  • 하태훈;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.430-437
    • /
    • 1998
  • The existing design expressions for shear strength of reinforced concrete columns are lacking in consistent seismic design philosophy and very conservative. However, relatively not so many experiments have been conducted to verify the shear resisting mechanisms of columns. The previous researches concentrated on deriving an experimental model from their test results. So, there is a need to approach this problem from the analytical point of view to be balanced with the experimental effort. This paper presents a method of modeling reinforced concrete columns under seismic shear loading. Lower bound solutions are obtained by using an analogous truss model and concrete arch actions. This model agrees with the precedented test results by some margins.

  • PDF