• 제목/요약/키워드: Resistant performance

검색결과 673건 처리시간 0.022초

연초 버어리종 웅성불임 일대잡종 KB 111의 육성경과 및 농경적 특성

  • 정석훈;조천준;최상주;조명조
    • 한국연초학회지
    • /
    • 제20권2호
    • /
    • pp.153-159
    • /
    • 1998
  • The vein necrotic strain of Potato Virus Y (PVY - VN) and black shank (Phyto-phthora parasitica var. nicotianae) are the two major diseases causing severe damages especially in burley tobacco (N. tabacum L.) area in Korea. A new tobacco variety, KB 111, resistant to PVY and black shank disease, was developed by Korea Ginseng & Tobacco Research Institute in 1997. It is a male sterile(MS) F$_1$ hybrid of the cross between MS TC 613 and KB 108. KB 111 was compared to Burley 21 on the agronomic characteristics and disease resistances in performance tests: It possessed upright growth habit and flowered two days later than Burley 21. It was resistant to both PVY and black shank and yielded about 3% more cured leaf than Burley 21, but other characteristics are very simiar to those of Burley 21. The chemical composition and physical properties of the cured leaf of KB 111 were as much acceptable as those of Burley 21 while it produced average yield of good quality leaf and appeared to resistant to PVY and black shank disease on regional farm test in 1998.

  • PDF

Hydrothermally synthesized Al-doped BiVO4 as a potential antibacterial agent against methicillin-resistant Staphylococcus aureus

  • Vicas, Charles Sundar;Keerthiraj, Namratha;Byrappa, Nayan;Byrappa, Kullaiah
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.566-571
    • /
    • 2019
  • One-pot hydrothermal route was adopted to synthesize Al:BiVO4, at 4 h and 8 h reaction durations, by adding 1% aluminiumoxide powder (w/v) to the precursors. The products were investigated using several characterization techniques that conform a significant morphological change and a decrease in bandgap energy of the materials upon Al modification of scheelite monoclinic bismuth vanadate matrix at both hydrothermal durations. Antibacterial experiments were performed against methicillin-resistant Staphylococcus aureus in visible light condition to harness the photoxidation property of Al-doped BiVO4 and compare to that of unaltered BiVO4. Minimum inhibitory concentration of the synthesized materials was identified. The results indicate that Al-doping on BiVO4 has a significant effect on its photocatalytic antibacterial performance. Al:BiVO4 synthesized at 8 h hydrothermal treatment parades excellent sunlight-driven photocatalysis compared to the one synthesized at 4 h.

SPA에 견디는 스칼라 곱셈 방법과 하드웨어 (A Scalar Multiplication Method and its Hardware with resistance to SPA(Simple Power Analysis))

  • 윤중철;정석원;임종인
    • 정보보호학회논문지
    • /
    • 제13권3호
    • /
    • pp.65-70
    • /
    • 2003
  • 본 논문에서는 side-channel 공격법 중 SPA(Simple Power Analysis)에 견디면서도 효율적인 연산이 가능한 scalar multiplication 방법과 하드웨어 구조를 제시한다. 기존에 제시된 SPA에 견디는 스칼라 곱셈 방법은 연산 속도가 느린 것이 약점이다. 따라서 이를 보안하는 방법에 대한 연구는 중요한 분야이다. 본 논문에서 제시한 타원곡선암호법 전용 하드웨어는 SPA에 견디면서도 동일한 유한체 연산기(multiplier, inverter)를 사용한다는 가정 하에 Coron의 방법 보다 연산 속도가 빠른 스칼라 곱셈 방법과 구조를 제시한다. 논문에서 제시하는 하드웨어는 n비트 키를 사용할 때 연산 속도가 2n·(Inversion cycle)+3(Multiplication cycle)만이 소요된다.

강도저항형 코어와 프레임 구조의 진동주기차를 이용한 듀얼프레임 제진시스템의 응답특성 (Response Characteristic of the Dual-frame Passive Control System with the Natural Period Difference between the Strength Resistant Core and Frame Structure)

  • 김태경;최광용;오상훈;유홍식
    • 한국지진공학회논문집
    • /
    • 제19권6호
    • /
    • pp.273-282
    • /
    • 2015
  • In this study, shaking table test has been carried out for the dual frame passive control system for seismic performance verification of the proposed system. The proposed system was separated into two independent frameworks that are strength resistant core and frame structure by connecting to the damper. Moreover, the seismic performance improvement of the proposed system has been verified by comparing and analyzing the experimental results of the proposed system with an existing core system. As a result of the shaking table test, acceleration and displacement responses of dual-frame vibration control system are decreased than those of the existing strength resistant type core system. In the case of the core system, while the damage was concentrated on the column of first floor, the damage of the dual system was dispersed in each layer. The damage also was concentrated on the damper, almost no damage occurs to the structural members. It has been emphasized that installed dampers in the proposed dual system reduce the input energy of whole structure by absorbing seismic input energy, which leads overall system damage to be reduced.

동적 탄소성 지진응답해석에 의한 고층 벽식 아파트의 내진성능 검토 (Earthquake Resistant Performance of a High-rise Shear Wall Apartment Based on Nonlinear Time History Response Analysis)

  • 박성수
    • 한국지진공학회논문집
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 1999
  • 본 논문의 목적은 탄소성 지진 응답해석을 수행하여 고층 벽식 아파트의 내진성능을 평가하는 것이다 먼저 구조물을 3차원 입체 모델화 하여 정적 탄소성 해석을 수행하고 층강성 및 항복 충전단력을 평가한 후 그 결과를 이용하여 집준 질량계 모델을 사용한 시간 이력 지진 응답해석을 수행한다 탄소성 이력 모델로는 bi-linear 모델 및 Clough 모델을 입력 지진동파형으로는 4종류의 기록 지진동 띠 Centro 1940 NS, Taft 1952 EW Hachinohe 1968 NSm Kobe 1995 NS를 사용하고 입력 지진동의 강도는 최대 지반속도치 12Kine이 되도록 크기를 조절하여 입력한다 탄소성 지진응답 해석결과 고층 벽식 아파트는 진도 5정도의 지진동 크기에서 전층에소성 변형이 발생하여 취약한 내진성능을 보여준다.

  • PDF

내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 저항성 평가 (Evaluation of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance)

  • 원종필;최석원;박찬기;박해균
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.559-568
    • /
    • 2006
  • 본 연구의 목적은 화재에 의하여 붕괴 위험성이 있는 터널콘크리트 구조물을 보호하기 위해서 사용하는 습식 고강도 폴리머 스프레이 모르타르의 역학적 특성과 화재저항성을 평가하는 것이다. 본 연구의 주요 목적은 낮은 강도를 가지고 있어 내화재료로서 충분하지 않은 현재 사용되고 있는 재료의 단점을 극복하기 위하여 강도와 화재저항성을 동시에 증가시키는 것이다. 또한 습식 고강도 폴리머 스프레이 모르타르의 피복두께에 따른 내부온도분포를 평가하였으며 화재가 발생하였을 경우 터널콘크리트 구조물을 보호할 수 있는 습식 고강도 폴리머 스프레이 모르타르의 최적두께를 결정하였다. 본 연구의 결과 습식 고강도 폴리머 스프레이 모르타르는 현재 상용화되어 있는 내화용 재료와 비교하여 강도가 높았으며, 우수한 내화성능을 확보하였다. 무엇보다도 화재로부터 기존 구조물을 보호하기 위한 고강도 폴리머 모르타르의 최적 피복두께는 4cm이상 이었다.

고준위 폐기물 처분용기 내진 해석 모델 개발 (Development of an Earthquake-Resistant Model for a High-Level Waste Disposal Canister)

  • 최영철;윤찬훈;김현아;최희주
    • 터널과지하공간
    • /
    • 제24권4호
    • /
    • pp.316-324
    • /
    • 2014
  • 고준위 방사성 폐기물 처분시스템은 지하 500 m 심도에서 암반에 터널을 뚫어 고준위폐기물 처분용기를 넣고 주위를 완충재로 매우는 형태이다. 많은 통계 자료에 의하면 한반도에서 매년 지진이 증가하는 추세이며, 지진이 발생할 경우 지하에서 발생된 전단력에 의해 처분용기가 손상될 수 있다. 더 나아가 방사성 유해물질이 유출되어 큰 환경 문제가 유발될 수 있다. 이에 본 논문에서는 지진에 대해 안전하게 보호할 수 있는 방법으로 내진형 완충재를 개발하였다. 내진 성능에 영향을 미치는 주요인자를 분석하여 내진형 완충재를 설계하였고, ABAQUS를 이용하여 전단해석모델을 개발하여 내진형 완충재의 성능을 평가하였다.

건축물 내진성능평가에 의한 지진재해관리정보체계 구축 (Construction of Earthquake Disaster Management System Based on Seismic Performance Evaluation of Architectural Structure)

  • 김성삼;조은래;윤정배;유환희
    • 대한공간정보학회지
    • /
    • 제15권3호
    • /
    • pp.59-67
    • /
    • 2007
  • 본 논문에서는 도시지역 내 건축물의 지진 안전도를 평가하기 위하여 건축 구조학적인 자료조사와 실험결과를 데이터베이스화하고 여기에 GIS를 연계하여 지진의 위험도를 체계적으로 관리하고 분석할 수 있는 지진재해관리용 정보체계구축의 가능성을 제시하였다. 내진성능 평가를 위하여 건축물 대장과 건축도면, 수치지형도 등을 활용하여 건물의 구조, 주요 구조부재 등 지진내진평가 항목별로 자료를 수집 정리한 후 현장조사를 통해 자료를 보완하였으며, 내진 성능평가를 실시하고 종합평가지수를 산정한 후 지진 위험도를 평가함으로서 지진재해를 효과적으로 대처하고 관리할 수 있는 GIS 기반 정보체계를 구축하였다. 향 후 건물별 지진 위험도를 평가하는 절차와 방법을 모듈화 할 경우 보다 신속하고 정확한 지진재해정보관리체계를 구축할 수 있을 것으로 판단된다.

  • PDF