• Title/Summary/Keyword: Resistance-type

Search Result 4,036, Processing Time 0.029 seconds

Clinical Significance of Airway Resistance Curve by the Body Plethysmograph (Body Plethysmograph를 이용한 Airway Resistance Curve의 임상적 의의)

  • Cheon, Seon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.218-225
    • /
    • 1995
  • Background: Airway resistance(Raw) is measured with the body plethysmograph by displaying the relationship between airflow and alveolar pressure($V/P_A$). If the resistance curve on $V/P_A$ tracing is curved or looped, the estimation of Raw is difficult. This study was designed to examine wheather there is any correlation between the shape of resistance curve and the clinical status and the pulmonary function of patients. Methods: The 146 pulmonary disease patients with increased Raw were included in this study. The shapes of resistance curves on $V/P_A$ tracing with body plethysmograph during quiet breathing were analyzed and compared with pulmonary function. Results: The results were as follows ; 1) The shapes of resistance curves were summarized in 5 categories; type 1: linear, type 2: ovoid, type 3: sigmoid, type 4: scoop, type 5: paisley. The type 3 except 1 case, type 4 and type 5 were found to have loop mainly in expiratory phase. 2) Although the shapes of resistance curves were not typical for specific disease, the resistance curves of acute disease tended to belong to type 1 or 2 and those of chronic airflow obstruction tended to belong to type 3, 4 or 5. But resistance curves of bronchial asthma and destructive lung with tuberculosis showed all types in proportion to degree of airflow obstruction or destruction of parenchyme. 3) In the cases of resistance curves going to type 5 rather than type 1 and those with looping, airflow obstuction tended to be severe and airway resistance and residual volume tended to increase. Conclusions: Analysis of resistance curve on $V/P_A$ tracing measuring airway resistance is helpful for judging degree of airflow obstruction and air trapping. Although the shape of resistance curve is not typical for specific disease, there is a close association between looping and airway obstruction.

  • PDF

Shear resistance characteristic and ductility of Y-type perfobond rib shear connector

  • Kim, Sang-Hyo;Park, Se-Jun;Heo, Won-Ho;Jung, Chi-Young
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.497-517
    • /
    • 2015
  • This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.

Classification of Korean Rice Cultivars based on Reaction Pattern to Japanese Isolates of Blast Pathogen

  • Jin, Xuan-Ji;Lee, Eun-Jeong;Choi, Jae-Eul
    • Journal of Crop Science and Biotechnology
    • /
    • v.10 no.1
    • /
    • pp.3-7
    • /
    • 2007
  • Classification of blast resistance type of 129 Korean rice cultivars was carried out based on reaction pattern to 10 Japanese blast pathogen isolates(Pyricularia oryzae). The cultivars were divided into 11 groups based on the presumed resistance genes as follows; Pia type(19 cultivars), Pita-2 type(4), Pik type(3), Pib type(5), Piz type(11), Pik-s type(8), Pik and Pii type(4), Pia and Pita type(8), Pia and Pik type(6), Pita, Pik and Pii type(4) and no-grouping type(57). These results would provide important information to rice breeding for durable and broad resistance to rice blast.

  • PDF

Measuring Experiment of Resistance Force on a Reciprocating Motion of Rod Type Piston (로드형 피스톤의 왕복운동 저항력 측정실험)

  • 함영복;박경민;김성동;최병오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.486-489
    • /
    • 2003
  • To reduce lateral force of traditional plunger type piston in the swash plate type hydraulic piston pumps and motors, we have proposed rod type piston with ball joint on both ends. We have studied the theoretical reaction force on two types of piston moving in the cylinder block bore. and made an experiment for the resistance force measurement on a reciprocating motion of plunger and rod type piston, changing the test condition such as swash plate angel and supply oil pressure and so on. As a result. a rod type piston has more smaller resistance force, about 29%. than a plunger type one.

  • PDF

Effects of Density, Temperature, Size, Grain Angle of Wood Materials on Nondestructive Moisture Meters

  • Pang, Sung-Jun;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.40-50
    • /
    • 2019
  • The aim of this study was to investigate the effects of density, temperature, size, and grain direction on measurement of moisture contents (MC) of wood materials non-destructively. The MC of different sizes of solid wood, glulam, and CLT from larch (larix kaempferi, $560kg/m^3$) and pine (pinus koraiensis, $430kg/m^3$) were measured using the dielectric type and resistance type meters. The specimens were conditioned in the environmental chamber to be equilibrium moisture content (EMC) of 12 % and 19 %. When density setting in dielectric type meter was increased from $400kg/m^3$ to $600kg/m^3$, the MCs of specimen (S-L-100-E) were decreased from 13.4 % to 11.3 %. However, when wood group (WG) setting in resistance type meter was changed from WG1 to WG4, the measured MCs were increased from 9.2 % to 12.3 %. When temperature setting in resistance type meters was changed from 0 to $35^{\circ}C$, the MC was decreased from 17.0 % to 13.0 %. The MCs measured by dielectric type meter for larger specimens (S-L-100-E_11.3 %, G-L-240-E_11.7 % and C-L-120-E_12.8 %) were higher than those of small size specimens (S-L-30-E_8.7 %, G-L-150-E_10.3 %, and C-L-90-E_9.7 %). The MCs measured by resistance type meter for larger specimens (G-L-240-E_11.6 % and C-L-120-E_13.3 %) were also higher than those of small size specimens (G-L-150-E_10.4 %, and C-L-90-E_11.8 %). The resistance type meter was not affected by the grain direction but the dielectric type meter were affected by the grain direction. The MC measured by resistance type meter for G-L-120-E perpendicular to grain direction was 11.5 % and the measured MC parallel to grain direction was 11.3 %. The MC measured by dielectric type meter parallel to grain direction (12.1 %) was higher than that measured perpendicular to grain direction (10.7 %).

The Effects of Resistance Exercise Program for Elders with Type 2 Diabetes on the Self Care, Stress and HbA1c (저항운동 프로그램이 제 2형 당뇨병 노인의 자가간호, 스트레스 및 당화혈색소에 미치는 효과)

  • Lee, Sun-Woo;Shin, Sung-Rae
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.3
    • /
    • pp.431-442
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effects of resistance exercise program for elders with type 2 Diabetes on the self care, stress and HbA1c. Methods: Thirty three elders with type 2 Diabetes(18 experimental and 15 control subjects) were selected conveniently among the aged who had been enrolled in a community senior center. The subjects in experimental group participated in a resistance exercise program for 8 weeks. Data were analyzed using the SPSS/Win 12.0. Results: The resistance exercise program showed a statistical difference in self care(t=-4.39, p=.000) and stress(t=2.22, p=.034). However, there was not a statistical difference in HbA1c (F=.556, p=.557), but experimental group had decreased continuously in HbA1c after the program. Conclusion: The resistance exercise program improved self care and reduced the stress in the elders with type 2 Diabetes. Therefore, resistance exercise program can be applied as an effective nursing intervention to promote self care, decrease the stress and to prevent complication for the elders with type 2 Diabetes.

  • PDF

Effects of Corrosion Resistance Characteristics of Opponent Materials in relative Motion on Sliding Wear Behavior of Mild Carbon Steel (상대재 내식성이 철강재료의 미끄럼마모 특성에 미치는 영향)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.35 no.2
    • /
    • pp.139-147
    • /
    • 2019
  • This study investigates the effects of corrosion resistance characteristics of opponent materials in relative motion on the sliding wear behavior of mild carbon steel. Pin specimens made of mild carbon steel are tested at several sliding speeds against mating discs made of two types of alloyed steels, such as type D2 tool steel (STD11) and type 420 stainless steel (STS420J2), with different corrosion resistance characteristics in a pin-on-disc type sliding wear test machine. The results clearly show that the sliding wear behavior of mild carbon steel is influenced by the corrosion resistance characteristics of the mating disc materials at low sliding speeds. However, the sliding wear behavior at high sliding speeds is irrelevant to the characteristics because of the rising temperature. During the steady state wear period, the sliding wear rate of mild carbon steel against the type 420 stainless steel at a sliding speed of 0.5 m/s increases considerably unlike against the type D2 tool steel. This may be because the better corrosion resistance characteristics achieve a worse tribochemical reactivity. However, during the running-in wear period at low sliding speeds, the wear behavior of mild carbon steel is influenced by the microstructure after heat treatment of the mating disc materials rather than by their corrosion resistance characteristics.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

Current Status of the Durability Study of Concrete Made with Various Cements in Korean Marine Environment (한국해양조건에서의 시멘트 종류별 콘크리트 내구 특성)

  • 박춘근;엄태형;정해문;임정렬;지정식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.163-169
    • /
    • 1997
  • The sea water resistance of cement and concrete must be considered when it is used for construction on the seashore of in the ocean. The concrete specimens using seven type of cements such as ordinary Portland cement, moderate heat Portland cement, sulfate resistance Portland cement, type A. B. C Portland blastfurnace slag cement and Portland flyash cement were immersed for 10 years in seawater in Kunsan. This study proved that moderate heat Portland cement, sulfate resistance Portland cement, type A Portland blastfurnace slag cement had higher resistance for seawater.

  • PDF

A Study on the ballistic impact resistance and dynamic failure behavior of aramid FRMLs by high velocity impact (고속충격에 의한 아라미드 섬유강화 금속적층재의 방탄성능 및 동적파손거동에 관한 연구)

  • 손세원;이두성;김동훈;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.527-532
    • /
    • 2000
  • The armor composite material targets such as aramid FRMLs with different type and ply number of face material and different type of back-up material, were studied to determine ballistic impact resistance and dynamic failure behavior during ballistic impact. Ballistic impact resistance is determined by $\textrm{V}_{50}$ ballistic limit, a statical velocity with 50% probability for complete penetration, test method. Also dynamic failure behaviors are respectfully observed that result from $\textrm{V}_{50}$ tests. $\textrm{V}_{50}$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during high velocity impact tests. As a result, ballistic impact resistance of anodized Al 5052-H34 alloy(2 ply) is better than that of anodized Al 5052-H34 alloy(1 ply), but Titanium alloy showed the similar ballistic impact resistance. In the face material, ballistic impact resistance of titanium alloy is better than that of anodized Al 5052-H34 alloy. In the back-up material, ballistic impact resistance of T750 type aramid fiber is better than that of CT709 type aramid fiber.

  • PDF