Shear resistance characteristic and ductility of Y-type perfobond rib shear connector |
Kim, Sang-Hyo
(Department of Civil and Environmental Engineering, Yonsei University)
Park, Se-Jun (Department of Civil and Environmental Engineering, Yonsei University) Heo, Won-Ho (Department of Civil and Environmental Engineering, Yonsei University) Jung, Chi-Young (Department of Civil and Environmental Engineering, Yonsei University) |
1 | Ahn, J.H., Lee, C.G., Won, J.H., and Kim, S.H. (2010), "Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement", J. Construct. Steel Res., 66(10), 1295-1307. DOI ScienceOn |
2 | Baran, E. and Topkaya, C. (2012), "An experimental study on channel type shear connectors", J Construct. Steel Res., 74, 108-117. DOI |
3 | Candido-Martins, J.P.S., Costa-Neves, L.F. and Vellasco, P.C.G.S. (2010), "Experimental evaluation of the structural response of perfobond shear connectors", Eng. Struct., 32(8), 1976-1985. DOI ScienceOn |
4 | Erdelyi, S. and Dunai, L. (2009), "Light-gauge composite floor beam with self-drilling screw shear connector: experimental study", Steel Compos. Struct., Int. J., 9(3), 255-274. DOI |
5 | European Committee for Standardization (2007), "prEN 1994-1-1 Design of Composite Steel and Concrete Structures Part 1-1: General rules and rules for buildings", CEN, Brussels, Belgium. |
6 | Kim, H.Y. and Jeong, Y.J. (2010), "Ultimate strength of a steel-concrete composite bridge deck slab with profiled sheeting", Eng. Struct., 32(2), 534-546. DOI ScienceOn |
7 | Kim, S.H., Ahn, J.H., Choi, K.T. and Jung, C.Y. (2011), "Experimental evaluation of the shear resistance of corrugated perfobond rib shear connections", Adv. Struct. Eng., 14(2), 249-263. DOI ScienceOn |
8 | Kim, S.H., Choi, K.T., Park, S.J., Park, S.M. and Jung, C.Y. (2013), "Experimental shear resistance evaluation of Y-type perfobond rib shear connector", J. Construct. Steel Res., 82, 1-18. DOI |
9 | Korea Highway Bridge Specifications (2010), Korean Ministry of Construction and Transportation. |
10 | Medberry, S.B. and Shahrooz, B.M. (2002), "Perfobond shear connector for composite construction", Eng. J., 2-12. |
11 | Oguejiofor, E.C. and Hosain, M.U. (1997), "Numerical analysis of push-out specimens with perfobond rib connectors", Comput. Struct., 62(4), 617-624. DOI |
12 | Papastergiou, D. and Lebet, J.P. (2014), "Design and experimental verification of an innovative steel-concrete composite beam", J. Construct. Steel Res., 93, 9-19. DOI |
13 | Vianna, J.C., Costa-Neves, L.F., Vellasco, P.C.G. da S. and Andrade S.A.L. (2009), "Experimental assessment of Perfobond rib and T-Perfobond shear connectors' structural response", J. Construct. Steel Res., 65(2), 408-421. DOI ScienceOn |
14 | Vianna, J.C., Andrade, S.A.L., Vellasco, P.C.G.S. and Costa-Neves, L.F. (2013), "Experimental study of perfobond shear connectors in composite construction", J. Construct. Steel Res., 81, 62-75. DOI |