• 제목/요약/키워드: Resistance variation

검색결과 1,246건 처리시간 0.033초

순전기자동차용 타여자직류기의 속도제어기 설계 (Design of a Speed Controller for the Separately Excited DC Motor in Application on Pure Electric Vehicles)

  • 현근호
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.6-12
    • /
    • 2007
  • In this paper, an robust adaptive backstepping controller is proposed for the speed control of separately excited DC motor in pure electric vehicles. A general electric drive train of PEV is conceptually rearrange to major subsystems as electric propulsion, energy source, and auxiliary subsystem and the load torque is modeled by considering the aerodynamic, rolling resistance and grading resistance. Armature and field resistance, damping coefficient and load torque are considered as uncertainties and noise generated at applying load torque to motor is also considered. It shows that the backstepping algorithm can be used to solve the problems of nonlinear system very well and robust controller can be designed without the variation of adaptive law. Simulation results are provided to demonstrate the effectiveness of the proposed controller.

유도전동기 회전자 저항 보상을 위한 벡터제어 (Vector Control for the Rotor Resistance Compensation of Induction Motor)

  • 박현철;이수원;김영민;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.65-68
    • /
    • 2001
  • In the vector control methods of induction motor, the stator current is divided into the flux and torque component current. By controlling these components respectively, the methods control independently flux and torque as in the DC motor and improve the control effects. To apply the vector control methods, the position of the rotor current is identified. The indirect vector control use the parameters of the machine to identify the position of rotor flux. But due to the temperature rise during machine operation, the variation of rotor resistance degrades the vector control. To solve the problem, the q-axis is aligned to reference frame without phase difference by comparing the real flux component with the reference flux component. Then to compensate the slip, PI controller is used. The proposed method keeps a constant slip by compensating the gain of direct slip frequency when the rotor resistance of induction motor varies. To prove the validations of the proposed algorithm in the paper, computer simulations is executed.

  • PDF

동일 분극방향의 디스크형 압전변압기 전기적 특성 (Electrical Characteristics of Disk-type Piezoelectric Transformer Poled with Same Direction)

  • 이종필;채홍인;윤만순;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.261-264
    • /
    • 2003
  • In this paper, a disk-type piezoelectric transformer for the high power was investigated with the variation of road resistance. The diameter and thickness of a disk-type piezoelectric transformer was 45mm and 4mm, respectively. The piezoelectric ceramics was composed to PZT-PMN-PSN. The ratio of driving electrode and generating electrode is 2:1. The poling direction of driving part and generating part are the same. A voltage step-up ratio increased with increasing the load resistance, $R_L$, so it reached 60 under no road resistance. Also, the maximum efficiency of 97% was obtained.

  • PDF

항만센서용 수정진동자의 해수에 의한 부식 (Corrosion of Quartz Crystal Marine Sensors in Sea Water)

  • 최광재;장상목;김영한
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.323-328
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the corrosion process of an aluminum surface of a quartz crystal for marine sensor by sea water. A quartz crystal having 2000 $\AA$ of aluminum layer is installed in a specially designed cell and is in contact with sea water imitated electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrometer(EDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of sensor surface.

  • PDF

폐유리를 혼입한 콘크리트의 황산마그네슘 저항성에 관한 연구 (Magnesium Sulfate Resistance of Concrete Containing Waste Glass)

  • 김영수;정유진;이동운
    • 한국건축시공학회지
    • /
    • 제9권3호
    • /
    • pp.109-116
    • /
    • 2009
  • The magnesium sulfate solution digestion test carried out for resistance of concrete containing waste glass powder on magnesium sulfate attack. Moreover, it yielded S.D.F index was used for the criteria of quantitative assessment to the resistance of magnesium sulfate for the purpose of evaluation of chemical deterioration on concrete. Furthermore, to evaluate for micro-cracks within concrete and external corrosion, the weight variation of specimens and the dynamic elasticity were compared and analyzed and also the applicability was examined using the analysis of product of hydration through out observing external deformation and micro-structural deformation.

전도성 CNT 박막의 온도에 따른 저항 변화도 연구 (Temperature-dependent Resistance Change of Conductive CNT Thin-film)

  • 권민규;홍용택
    • 한국전기전자재료학회논문지
    • /
    • 제22권2호
    • /
    • pp.151-157
    • /
    • 2009
  • This paper reports the resistance change of conductive carbon nanotube (CNT) thin-films according to the temperature variation. Resistance of conductive CNT thin-films intrinsically has good thermal sensitivity, but shows environmental dependency. In order to reduce environmental effects, we spin-coated polydimethylsiloxane (PDMS) on the conductive CNT thin-films. We observed that conductive CNT thin-films with a PDMS encapsulation layer showed little environmental dependency, but more linear and stable temperature dependencies. If proper encapsulation is provided, conductive CNT thin-films can be used for temperature sensor applications.

AC8A 알루미늄 합금 주조재의 열처리에 의한 특성 평가(II) (Evaluation of the Characteristics of the Aluminum Alloy(AC8A) Casting Material by Heat Treatment(II))

  • 문경만;정재현;이명훈;백태실
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.29-36
    • /
    • 2016
  • Aluminum alloys have been widely used in engine materials, cold & hot-water storage vessels and piping etc., Furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston for various vehicles because of its properties of temperature, wear and corrosion resistance. Therefore, it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and to prolong its lifetime. In previous paper, the effect of solution($510^{\circ}C$:4hrs) and tempering($190^{\circ}C$: 16, 24, and 36 hrs)heat treatments to corrosion resistance and hardness were investigated using electrochemical method. In this study, in order to examine completely the effect of the tempering hours to hardness variation and corrosion resistance, the results of solution($510^{\circ}C$:4hrs) and tempering($190^{\circ}C$: 2, 4, 8 and 12hrs)heat treatments to hardness and corrosion resistance were investigated using electrochemical method. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment. Furthermore, the corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. And the tempering heat treatment temperature at $190^{\circ}C$ for 8 hrs exhibited the highest value of the hardness and also indicated the highest corrosion current density. However, the values of hardness and corrosion current density was again increasingly decreased with increasing of tempering hours than 8 hrs, Consequently, it is suggested that decision of the optimum. tempering hours is very important to improve the corrosion or wear resistance.

CFD를 이용한 표면 거칠기에 따른 선박의 저항 성능 추정에 관한 연구 (A Study on Predicting Ship Resistance Performance due to Surface Roughness Using CFD)

  • 석준;박종천;신명수;김성용
    • 대한조선학회논문집
    • /
    • 제53권5호
    • /
    • pp.400-409
    • /
    • 2016
  • In recent, shipping companies have made an enormous effort to improve the operation of vessel in various approaches, due to recession of shipping market and increasing competition among shipping companies. One of important parameters for improving the efficiency of vessel is the resistance performance that consist of friction and residual resistance. Especially, it is recognized that the friction resistance tends to be affected by conditions of vessel’s surface and occupies approximately 70~90% of the total resistance for slow speed ships. In general, the surface of vessel is covered with various type of paint to reduce fouling and corrosion. As time goes by, however, it is so hull roughness would be increased by fouling over the wetted surface that anti-fouling paints, such as CDP(Controlled Depletion Paint), Tin-Free SPC(Self Polishing Co-polymer) or Foul Release, are applied evenly on the hull surface. Nevertheless, these anti-fouling paints could not prevent fouling absolutely. A fundamental study on evaluating ship resistance performance variation due to hull roughness has been performed using a commercial software, Star-CCM+, which solves the continuity and Navier-Stokes equations for incompressible and viscous flow. The results of present simulation for plate are compared with some experimental data available and the effect of surface roughness to ship resistance performance is discussed.

구기자품종의 구기자혹응애 저항성 유전 (Inheritance of Resistance to Gall Mite(Eriophys macrodonis) in Boxthorn (Lycium chinese) Cultivars)

  • 최재을;차선경;김영창;김진희;강희경
    • 한국자원식물학회지
    • /
    • 제15권3호
    • /
    • pp.298-304
    • /
    • 2002
  • 구기자품종의 혹응애에 대한 저항성 반응 및 저항성 유전양식 을 검정하기 위하여 저항성 품종과 감수성 품종을 인공교배 하여 얻은F$_1$집단의 포장자연 발생율에 의하여 저항성을 조사한 결과 다음과 같은 결과를 얻었다. 1. 구기자혹응애 저항성 품종인 일본 1호,중국 1호를 감수성인 CL42-56과 교배한 F$_1$은 혹응애 저항성과 감수성이 3 ; 1로 분리되었으며, 일본 1호와 중국 1호를 교배한 F$_1$은 혹응애 저항성과 감수성이 15 : 1로 분리 되었다. 2. 일본 1호와 중국 1호의 혹응애 저항성은 hetero 인 두 개의 우성유전자에 의해 지배되며, 저항성 유전자를 E1e1E2e2로 명명하였다. 3. 청양구기자를 CL42-56에 교배한 F$_1$은 혹응애 저항성과 감수성의 분리비가 명확하지 않았으며 변이 의 폭이 크므로 청양구기자의 혹응애 저항성은 주동유전자와 polygenes에 의해 지배되었다. 4. 일본 1호와 중국 1호는 혹응애 저항성 품종 육성을 위한 모본으로 우수하였으며, 청양구기자도 저항성 모본으로서 가치가 인정되었다.

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.