• 제목/요약/키워드: Resistance value

검색결과 2,569건 처리시간 0.041초

NiCr 박막저항의 전기적 특성 연구 (The study on electrical properties of the NiCr thin film resistor)

  • 류제천;김동진;김용일;강전홍;김한준;유광민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.275-278
    • /
    • 2000
  • We were fabricated of NiCr thin film resistors(TFR) on A1$_2$O$_3$(99.5%) substrates by dc magnetic sputtering system. The characteristics of electrical resistance (Sheet resistance & Temperature-Coefficient of the resistance-value:TCR) by annealing condition and reactive gas on the resistors were studied.

  • PDF

보정함수를 이용한 강판의 열간 압연하중 예측 정도향상 (Improvement of Rolling Force Estimation by Modificaiton Function for Hot Steel Strip Rolling Process)

  • 문영훈;이경종;이필종;이준정
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1193-1201
    • /
    • 1993
  • 본 연구에서는 통계학적 이론 및 희귀분석에 근거한 보정함수를 모델 수정에 도입하여 조업조건별로 예측오차 요인들을 제거함으로써 예측 모델의 정도를 향상시키 고자 하였다. 이를 위해 일반강에 비해 압연하중 모델의 예측정도가 상대적으로 낮은 극저탄소강을 대상으로 하여 압연조업에 따른 압연하중 예측모델의 오차요인을 조업인 자별로 분석하였고 적용시켜 모델의 적중도를 향상시켰다.

고분자 전해질 연료전지 금속분리판 316L 스테인리스강의 부식거동 및 기체확산층(GDL)과의 계면접촉저항 측정 (Corrosion Behaviors of 316L Stainless Steel Bipolar Plate of PEMFC and Measurements of Interfacial Contact Resistance(ICR) between Gas Diffusion Layer(GDL) and Bipolar Plate)

  • 오인환;이재봉
    • Corrosion Science and Technology
    • /
    • 제9권3호
    • /
    • pp.129-136
    • /
    • 2010
  • The corrosion behaviors of 316L stainless steel were investigated in simulated anodic and cathodic environments for proton exchange membrane fuel cell (PEMFC) by using electrochemical measurement techniques. Interfacial contact resistance(ICR) between the stainless steel and gas diffusion layer(GDL) was also measured. The possibility of 316L was evaluated as a substitute material for the graphite bipolar plate of PEMFC. The value of ICR decreased with an increase in compaction stress(20 N/$cm^2$~220 N/$cm^2$) showing the higher values than the required value in PEMFC condition. Although 316L was spontaneously passivated in simulated cathodic environment, its passive state was unstable in simulated anodic environment. Potentiostatic and electrochemical impedance spectroscopy (EIS) measurement results showed that the corrosion resistance in cathodic condition was higher and more stable than that in anodic condition. Field emission scanning electron microscopy (FE-SEM), and inductively coupled plasma(ICP) were used to analyze the surface morphology and the metal ion concentration in electrolytes.

수분의 흡수에 따른 구조용 목질판넬의 인발 및 함입성능 (Nail Withdrawal Resistance and Embedding Strength of Structural Wood Panels with Water Absorption)

  • 오세창
    • 한국가구학회지
    • /
    • 제10권2호
    • /
    • pp.1-8
    • /
    • 1999
  • The use of structural wood based panels like plywood, OSB in many applications involves the use of nails, and data on the performance of panel-nail connection are needed for design and comparative purpose. This study was carried out to develop basic information on nail performance(withdrawal, embedding, nailhead push through) with water absorption in plywood and OSB. In withdrawal resistance test, initial stiffness of plywood performed better than OSB in 24hr soaked condition. The soaked condition reduced average nail withdrawal resistance value about 46% (12d mail), 53%(8d nail) in OSB, 17%(12d mail), 24%(8d mail) in plywood. The nail embedding strength of plywood also performed better than that of OSB and retention value(wet strength/dry strength) yielded similar in each nail types. The nail head push through capacity of OSB was higher than that of plywood in dry condition, but equal or lower in soaked condition. Therefore, critical consideration about structural panels is required in moist applications. The average values of nail withdrawal, nail embedding strength and nail head push through resistance of tested materials meet the minimum requirement of various specification and standards.

  • PDF

L형측구 콘크리트 구조물의 표면박리파손 원인분석에 관한 연구 (A Study on the Analysis of Scaling Failure Cause in L-Shoulder Concrete Structure)

  • 전성일;남정희;안상혁;안지환
    • 한국도로학회논문집
    • /
    • 제16권6호
    • /
    • pp.27-37
    • /
    • 2014
  • PURPOSES : The purpose of this study is to verify the causes of surface scaling at L-shoulder concrete structure. METHODS : From the literature reviews, mechanisms of frost damage were studied and material properties including strength, air void, spacing factor and scaling resistance of L-shoulder concrete structure were analyzed using core specimens taken by real fields. RESULTS : The spacing factor of air void has relatively high correlation of surface conditions : lower spacing factor at good surfacing condition and vice versa. If the compressive strength is high, even thought spacing factor does not reach the threshold value of reasonable durability, the surface scaling resistance shows higher value. Based on these test results, the compressive strength also provide positive effect on the surface scaling resistance. CONCLUSIONS : The main causes of surface scaling of L-shoulder could be summarized as unsuitable aid void amount and poor quality of air void structure. Secondly, although the compressive strength is not the governing factor of durability, but it shows the positive effect on the surface scaling resistance.

남자 대학생의 착용 패션스타일과 음악·여가·라이프스타일·가치관과의 관계 (Relationship between Fashion Style and Music, Recreation, Lifestyle and Value of Male College Students)

  • 유혜경;백두진;고선영
    • 복식
    • /
    • 제63권4호
    • /
    • pp.44-55
    • /
    • 2013
  • The main objectives of this study were to empirically examine the relationship between the preference of fashion styles of male college students and their individual taste in other areas including music styles and recreation types. Life style and values were also examined for their relationship with the fashion style preferences. Survey questionnaires were distributed to male college students in Seoul, Incheon and Gyeonggi-do during May and June of 2011, and a total of 256 responses were used in the final analysis. The results showed that there were three segments according to the fashion styles - 'modern-dandy', 'resistance style', 'no-individuality' groups - and there were significant differences between groups in terms of their preferred music styles and choice of recreational activities. Modern-dandy group preferred R&B, dance music and ballad, while resistance style group preferred hiphop, dance and reggae music. No-individuality group did not show any preference for a particular type of music. Both modern-dandy and resistance style groups liked sports, while resistance style group showed the lowest preference for hobby and culture. There were also significant differences in lifestyles and values according to the fashion styles of the three groups.

메탈릭 자카드 직물 물리적 성능평가 (Physical Performance of Metallic Jacquard Fabrics)

  • 강덕희;이정순
    • 한국의류학회지
    • /
    • 제33권1호
    • /
    • pp.149-159
    • /
    • 2009
  • The purposes of this study are to evaluate physical performance of metallic Jacquard fabrics, and to contribute to the research and development of the women's suit made of the metallic Jacquard fabrics. First, eight fabrics were woven with two kinds of warp yarns(nylon and rayon) and weft yarn blended with various contents(0, 7, 14, 21%) of metallic yarn. Second, the mechanical properties were measured by using the KES-FB system, and physical properties such as tensile strength, tearing strength, abrasion resistance, drape, pilling, snagging, degree of crease resistance, flexural stiffness, specular gloss, folding endurance and electrostatic propensity were measured. The results were as follows. As the metal fiber content increased, bending, shear, thickness and weight increased, which imply low recovery of wrinkles. It means that metallic Jacquard fabrics enable to use as a memory fabric. 7% metallic Jacquard fabric showed a low value at total hand value, but there was little change. As the metal fiber content increased, tensile strength, tearing strength, drape coefficient, specular gloss and flexural stiffness increased, however the degree of crease resistance, electrostatic propensity and folding endurance decreased. The metallic Jacquard fabrics were excellent in snagging, abrasion resistance and pilling.

유선추적법(流線追跡法)에 의(依)한 구상선수선형(球狀船首船型)의 계획(計劃) 및 조파효과(造波效果) (Desigh and Wavemaking Effect of Bulvous Bow Ship by Stream Line Tracing Method)

  • 홍성완
    • 대한조선학회지
    • /
    • 제10권2호
    • /
    • pp.19-28
    • /
    • 1973
  • This paper deals with a problem for determining the bulbous bow ship from which pertains to the study of the theoretical ship form planing method. In this paper has been determined the bulbous bow ship form which is a similar in geometric particulars with the conventional liner ship G.T.10, 000 by adopting the variable method for finding the optimum ship form by A.Y.C. Lee and the streamline tracing method by T. Inui and P.C. Pien. Each resistance performance is examined by the towing test and is compared with one another. The followings are the outcome of this study: Among the 5 type models, the bulbous bow ship form M.S. B 1120 is the most excellent for the resistance performance. The effect for the wave resistance is very sharp according to the difference of the bottom flattening of theoretical ship form. The optimum value of the bulbous bow for wave resistance can be obtained by the variable method mentioned above, and for the series of(Main hull+Bulb)opt., ${\alpha}=75/25$, the value is $f{\approx}0.11$.

  • PDF

라이오셀방적사의 꼬임수에 따른 담요직물의 압축특성과 마모강도 (The Effect of Number of Twists of Lyocell Yarns on Compression Property and Abrasion Resistance Blanket Fabrics)

  • 송민규
    • 한국의류산업학회지
    • /
    • 제8권3호
    • /
    • pp.363-369
    • /
    • 2006
  • In this the study, Lyocell fabrics for blanket were developed to get high value added goods for elder and Infant. Therefore, the purpose of the study was determine the effect of twist per inch on the physical properties of developed fabrics, including compression property and abrasion resistance on the process for making Lyocell combined yarns. For comparison, commonly used cotton blanket was used. The results were as the follows: 1) Dimensional changes of Lyocell fabrics was in -3% which value was pretty stable, and antistatic property was very good with 10V of electric propensity voltage which means there was no static electricity at all. Pilling property of Lyocell fabrics showed 3 grade which was good and air permeability and moisture vapor transmission rate of Lyocell fabrics were higher than those of cotton fabric and keeping warmth rate of Lyocell fabrics was about 50% which means it very warms. 2) Twist per inch of Lyocell combined yarns increased with tensile strength and elongation of Lyocell fabrics. 3) Twist per inch of Lyocell combined yarns increased with decreasing thickness reduction rate and therefore, compression property of those was pretty good. Specially, compression property of Lyocell fabrics made with yarns of 3.9TPI was better than those of cotton fabric. 4) Twist per inch of Lyocell combined yarns increased with abrasion resistance of Lyocell fabrics.

업무용 건축물에 적용된 단열재의 경년열화에 따른 열손실량 분석 (Analysis of Heat Loss Due to Time Dependent Aging of Insulation Applied to Office Building)

  • 이도형;나환선
    • 한국태양에너지학회 논문집
    • /
    • 제37권5호
    • /
    • pp.65-75
    • /
    • 2017
  • In this study, the change of heat loss due to the degree of deterioration of the XPS insulation in KEPCO's office buildings is analyzed. The acceleration aging test of the XPS insulation was carried out according to the test method A of KS M ISO 11561: 2009. The performance of the insulation was analyzed by applying it to the three - dimensional steady state heat transfer analysis program. The acceleration aging test of the XPS insulation, show that the thermal resistance performance decreased by 1.44% at the A regional headquarters, 0.85% at the B regional headquarters, 6.41% at the C branch office, 7.76% at the D regional headquarters, 8.51% at the E branch office, and by 8.54% at the F branch office respectively. Using simulation, we determined that the thermal resistance value of E branch office decreased by 8.04%, while its heat loss increased by 8.52%. At A regional headquarters, the thermal resistance decreased by 1.38%, and the heat loss increased by 1.51%. At D regional headquarters, these value are 6.82% and 7.17%, respectively.