A Study on the Effect of Resonant Coil Size and Load Resistance on the Transmission Efficiency of Magnetic Resonance Wireless Power Transfer System (공진 코일의 크기와 부하 저항이 자계 공명 무선 전력 전송 장치의 전달 효율에 주는 영향에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.45-51
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed and the effect of resonant coil radius and load resistance to this system was analyzed by the circuit analysis method. As a result, the calculated transmitted-power is similar to measured one, and the coil size has a small effect to the coupling coefficients in the resonant frequency band. In addition, the fact that the calculated transmitted-power according to the source frequency is similar to measured one confirms that the circuit analysis methode in this paper is valid. The input side transmission efficiency ${\eta}_i$ including only the loss in the power transfer circuit is almost 90[%] with the large coil in the 10[cm] transfer distance, and 65[%] with the small coil in 1[cm]. The source side transmission efficiency ${\eta}_s$ is 30~40[%] at both coil when load resistance below 4.7[${\Omega}$] has been connected. Considering that the maximum ${\eta}_s$ is 50[%], this is valid in the practical applications.

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

Transfer Impedence of Trip Chain with a Railway Mode Embedded - Using Seoul Metroplitan Transportation Card Data - (철도수단이 내재된 통행사슬의 환승저항 추정방안 - 수도권 교통카드자료를 활용하여 -)

  • Lee, Mee young;Sohn, Jhieon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1083-1091
    • /
    • 2016
  • This research uses public transportation card data to analyze the inter-regional transfer times, transfer frequencies, and transfer resistance that passengers experience during transit amongst the metropolitan public transportation modes. Currently, mode transfers between bus and rail are recorded up to five times during one transit movement by Trip Chain, facilitating greater comprehension of intermodal movements. However, lack of information on what arises during these transfers poses a problem in that it leads to an underestimation of transfer resistances on the Trip Chain. As such, a path choice model that reflects passenger movements during transit activities is created, which attains explanatory power on transfer resistance through its inclusion of transfer times and frequencies. The methodology adopted in this research is to first conceptualize the idea of metropolitan public transportation transfer, and in the case that mode transfers include the city-rail, to newly conceptualize the idea of transfer resistance using transportation card data. Also, the city-rail path choice model within the Trip Chain is constructed, with transfer time and frequency used to reevaluate transfer resistance. Further, in order to align bus and city-rail station administrative level small-zone coordinates to state and regional level mid-zone coordinates, the big node methdod is utilized. Finally, case studies on trip chains using at least one transfer onto the city-rail is used to determine the validity of the results obtained.

Antimicrobial Drug Resistance in Shigella cultures Isolated in Korea (1983) (이질균속의 항균제 내성)

  • Jung, Tae-Hwoa;Lee, Myung-Won;Lee, Bok-Kwon;Kim, Ki-Sang;Lee, Hun-Goo;Lee, Yun-Tai;Hong, Sung-Ro
    • The Journal of the Korean Society for Microbiology
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 1984
  • One hundred and forty strains of Shigella cultures isolated from the twelve hygiene laboratories of cities and provincial level and general hospital laboratories in 1983, and were tested for their resistance to 13 antimicrobial drugs and their R-Plasmid transfer. One hundred and forty (100%) of isolates were susceptible to amikacin, gentamicin, tobramycin, a total of 94.3% of all shigella isolates were resistant to 1 or more of the 13 antimicrobial agents tested. The most commonly found resistance was to chloramphenicol (94%), followed by streptomycin (93%), tetracycline (92%), piperacillin (90%), ampicillin (83%), cefoperazone (42%), nalidixic acid (14%), cephalothin (17%), rifampicin (22%), and kanamycin (6%). Sixty percent of strains among 140 were resistant to ampicillin, chloramphenicol, streptomycin, tetracycline at same time. The transfer of drug resistance by conjugation was tested and 94 strains (94.3%) which were resistant to one or more drugs were found to transfer their drug resistance to E. coli.

  • PDF

Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition (착상조건하에서 평행 평판 열교환기의 열 및 물질전달)

  • Lee, K.S.;Lee, T.H.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

In-depth Investigation on Interfacial Resistance of Stainless Steel by Using Dynamic Electrochemical Impedance Spectroscopy (Dynamic Electrochemical Impedance Spectroscopy를 이용한 스테인리스 강의 계면 저항 분석)

  • Heo, Jung-Ho;Lee, Yong-Heon;Shin, Heon-Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.10
    • /
    • pp.644-651
    • /
    • 2009
  • The passivation (or deactivation) of a metal surface during oxide film formation has been quantitatively explored for a ferritic stainless steel by using dynamic electrochemical impedance spectroscopy (DEIS). For this purpose, the electrochemical impedance spectra were carefully examined as a function of applied potential in the active nose region of the potentiodynamic polarization curve, to separate the charge transfer resistance and oxide film resistance. From the discrepancy in the potential dependence between the experimental charge transfer resistance and the semi-empirically expected one, the degree of passivation could be quantitatively estimated. The sensitivity of passivation of the steel surface to anodic potential, which might be the measure of the quality of the oxide film formed under unit driving force or over-potential, decreased by 31% when 3.5 wt% NaCl was added to a 5 wt% $H_2SO_4$ solution.

Load-Transfer Analysis by Considering Coupled Soil Resistance (말뚝-지반 상호작용을 고려한 수정된 하중전이함수법 제안)

  • Seol, Hoon-Il;Jeong, Sang-Seom;Kim, Young-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6C
    • /
    • pp.359-366
    • /
    • 2008
  • The load distribution and deformation of pile subjected to axial loads are evaluated by a load-transfer method. The emphasis is on quantifying the effect of coupled soil resistance that is closely related to the ratio of pile diameter to soil modulus $(D/E_s)$ and the ratio of total shaft resistance against total applied load $(R_s/Q)$, in rock-socketed drilled shafts using the coupled load-transfer method. The proposed analytical method that takes into account the soil coupling effect was developed using a modified Mindlin's point load solution. Through comparisons with field case studies, it was found that the proposed method in the present study estimated reasonable load transfer behavior of pile and coupling effects due to the transfer of shaft shear loading, and thus represents a significant improvement in the prediction of load deflections of drilled shafts.

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

Drug Resistance and R. Plasmids of Enterobacteria Isolated from Bovine Udder Infections (젖소 유방염유래(乳房炎由來) 장내세균(腸內細菌)의 약제내성(藥劑耐性) 및 R. Plasmids)

  • Park, Cheong Kyu
    • Korean Journal of Veterinary Research
    • /
    • v.21 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • A total of 250 enteric bacteria (148 Escherichia coli, 41 Klebsiella pneumoniae, 46 Enterobacter spp. and 15 Proteus spp.) isolated from bovine udder infections in 1979 through 1980 were examined for drug resistance and prevalence of R. plasmids. The drug tested were streptomycin (SM), kanamycin (KM), ampicillin (AP), chloramphenicol (CP), tetracycline (TC), gentamicin (GM), oxolinic acid (OA) and nalidixic acid (NA). The detection of R. plasmids was performed with Escherichia coli ML 1410 NAr as the recipient. Of the 148 Escherichia coli isolated, 68(45.9%) were found to be resistant to one or more drugs tested, and about 50% of the resistant strains were multiply resistant. of the 68 drugresistant strains, 13(19.1%) were found to carry R. plasmids which were capable of performing a conjugal transfer. CP resistance was transfered together with the other resistance. Of 41 strains of Klebsiella pneumoniae isolated, 90.2% were resistant to the drugs, alone or in combination thereof. Strains resistant to AP and TC were 63.4%, and 48.8%, respectively. R. plasmids were detected in 78.4% of the drug-resistant strains, and these strains transfered all or a part of their drug resistance pattern. AP and CP resistance were transfered in 100% of AP and CP-resistant strains. Eleven (37.9%) of 29 R. plasmids showed a thermosensitive transfer. Of the 46 strains of Enterobacter spp. isolated, 37(80.4%) were resistant to the drugs tested. A high percentage of resistance was noted for AP(65.2%). All strains resistant to four or more drugs transferred their resistances to Escherichia coli ML 1410, but strains resistant to three or fewer drugs did not transfer the resistances. All of the 15 Proteus strains isolated were resistant to more than two drugs. of them, 6 were quadruple resistance to SM, KM, CP and TC, and 9 were double one to AP and TC. Three (20.0%) of the drug-resistant isolates had R.plasmids conferring AP and TC resistance. GM, OA and NA of the drugs tested were very active to all of 250 Gram-negative enteric bacteria isolated from bovine udder infections.

  • PDF

The Effects of Graphite and Magnesium Oxide in Automotive Friction Materials on Friction and Formation of Transfer Film (자동차용 마찰재에 사용되는 흑연과 마그네시아에 따른 전이막과 마찰특성에 관한 연구)

  • Bae, Eun-Gap;Yoon, Jang-Hyuk;Jang, Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.226-234
    • /
    • 2002
  • A systematic study of the role of transfer films on friction properties was performed with various temperatures in the brake system. An NAO friction material specimens containing 9 ingredients were tested using a pad-on-disk type friction tester A new method of measuring the transfer film thickness was developed by considering the electrical resistance of the transfer film using a 4-point probe technique. The properties of transfer film such as surface morphology and film distribution vaied according to the relative amount of graphite and magnesium oxide. By using SEM, it was possible to obtain information about the chemical composition of the transfer film. Results showed that there detected a threshold value of the relative amount of a two active materials to maintain a certiain thickness of a transfer film. Results also showed that formation of friction layer generated on the friction surface was strongly affected by chemical action of two ingredients during sliding due to chemical reaction of solid lubricants at different interface temperature. The results suggested that no apparent relationship between transfer film thickness and the average friction coefficient was founded and friction characteristics were affected more by the property of the solid lubricant and abrasive in the material.

  • PDF