• Title/Summary/Keyword: Resistance to Motion

Search Result 369, Processing Time 0.023 seconds

A Study on Magnitude Scaling Factors and Screening Limits of Liquefaction Potential Assessment in Moderate Earthquake Regions (중진지역에 적합한 액상화 평가 생략기준 및 지진규모 보정계수에 관한 연구)

  • Park Keun-Bo;Park Young-Geun;Choi Jae-Soon;Kim Soo-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.127-140
    • /
    • 2004
  • Conventional methods for the assessment of liquefaction potential were primarily for areas of severe earthquake zones (M=7.5) such as North America and Japan. Detailed earthquake related researches in Korea started in 1997, including development of the seismic design standards for port and harbour structures, which was later completed in 1999. Because most contents in the guidelines were quoted through literature reviews from North America and Japan, which are located in strong earthquake region, those are not proper in Korea, a moderate earthquake region. This requires further improvement of the present guidelines. Considering earthquake hazard data in Korea, use of laboratory tests based on irregular earthquake motion appears to be effective to reflect the dynamic characteristics of soil more realistically than those using simplified regular loading. In this study, cyclic triaxial tests using irregular earthquake motions are performed with different earthquake magnitudes, relative densities, and fines contents. Assessment of liquefaction potential in moderate earthquake regions is discussed based on various laboratory test results. Effects of these components on dynamic behavior of soils are discussed as well. From the test results, screening limits and magnitude scaling factors to determine the soil liquefaction resistance strength in seismic design were re-investigated and proposed using normalized maximum stress ratios under real irregular earthquake motions.

Design of Motor-driven Traveling System for High Clearance Working Machinery based on Tractive Performance and Hill Climbing Ability (견인 및 등판 성능을 통한 고소작업기계의 모터 주행장치 설계)

  • Lee, Sangsik;Jang, Seyoon;Kim, Taesoo;Nam, Kyoucheol;Park, Wonyeop
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.3
    • /
    • pp.257-265
    • /
    • 2016
  • In this study, an optimal design for motor-driven track type traveling system applied into high clearance working machineries in orchard is proposed. Tractive performance and hill climbing ability were predicted and evaluated for the optimal motor traveling system by taking into account of soil characteristics in orchard utilizing the high clearance working machineries. Design criteria for tractive performance were based on the traction force calculated from tractive effort subtracted by motion resistance, while hill climbing ability had its design criteria that fulfill the climbing 20% slope ground at a speed of 3km/h. Based on the evaluation results of traction and climbing ability, two DC48V, 4500rpm, 1.6kW AC motors were independently applied to both left and right side of orbits; each motor is designed to transmit power on driving sprocket of track type traveling system via 50:1 reduction gear ratio. The motor-driven track type traveling system developed in the study found to have 396 kgf of tractive force, which is 12.5% higher than climbing resistance at orchard soil having 20% slope ground (352 kgf), demonstrating sufficient tractive performance and hill climbing ability.

The Kinetic Analysis of the Lower Extremity Joints when Performing Uchi-mata by Uke's Posture in Judo (유도 허벅다리걸기 기술 발휘 시 받기 자세에 따른 하지관절의 kinetic 분석)

  • Yoon, Hyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.167-183
    • /
    • 2005
  • The purpose of this study was to analyze the kinetical variables of the lower extremity joints when performing uchimata(inner thigh reaping throw) by uke(receiver)'s two posture(shizenhon tai), jigohon tai), by voluntary resistance level(VRL) in judo. The subjects, who were for 3 male Korean national representative judokas(elite group : EG) and 3 male representative judokas of Korean University(non-elite group: NEG), and were filmed 4 DV video cameras(60fields/sec.), that posture of uke were shizenhon-tai (straight natural posture), jigohon-tai(straight defensive posture), VRL of uke was 0%. The selected trials were subject to 3-dimensional film motion analysis and ground reaction force(MRF) analysis. The kinetical variable of this study were temporal, postures( ankle and knee angle of attacking leg), that were computed through video film analysis, MRF at events were obtained from the ground-reaction force analysis by AMTI force plate system. When performing uchi-mata according to each posture and by VRL, from the data analysis and discussion, the conclusions were as follows : 1) Temporal variables : total time-required(TR) when performing uchi-mata was shown EG 0.13sec the shorter than NEG(o.77sec.) in shizenhon-tai. and EG 0.17sec the shorter than NEG(o.76sec.) in jigonhon-tai. Also, all of two groups' jigohon-tai(0.68sec.) were faster than shizenhon-tai(0.71 sec.). 2) The posture variables : The angle of ankle in attacking when performing were plantar flexion in EG, and dorsi flexion in NEG by shizenhon-tai and jigohon-tai posture. The angle of knee in attacking when performing were extension in EG and NEG, but range of extension in EG were larger than in NEG. 3) MRF : Vertical MRF when performing uchi-mata was shown the strongest in the 2nd stage of kake phase(2.23BW) by EG in both posture, and it was same value by NEG(2.23BW), but shizenhon-tai (2.28BW), jigohon-tai(1.64BW), respectively.

Evalution of Earthquake Resistance capacity of Semi-rigid Mid/Low-rise Steel Frame using Composite Panel (복합소재패널을 이용한 반강접 중저층 강골조의 내진성능평가)

  • Chang, Chun-Ho;Lee, Taek-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1805-1813
    • /
    • 2010
  • This paper presented regarding an parametric study to investigate seismic capacity evaluation of semi-rigid steel frame infilled with composit panel. In order to propose the optimum retrofit of the steel frame, we analysed the various pattern of retrofitted steel frame subjected to weak/medium earthquake. Steel frame with composit panel was analysed by Time history analyses analysis. The model were analysed using the suites of ground motion developed by NEHRP project on steel moment resisting frame. These earthquakes consist of 20 horizontal ground acceleration record each, i.e., a 10%, 50% probability of accidence in a 50 year period. We considered the semi-rigid connection which are commonly used in field, and modeled the nonlinear connection element (GAP) between panel and frame. It was shown that how is the steel frame with composit panel effected. We also examined the response of retrofitted frame.

Evaluation on Fatigue Behavior of EP(Engineering Plastic) Friction Pendulum Bearing System (EP가 적용된 마찰 진자형 지진격리받침의 피로거동분석)

  • Choi, Jung-Youl;Park, Hee-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.703-708
    • /
    • 2020
  • As the risk of earthquakes increases recently, earthquake-resistant designs were getting interest. For this reason, this study applies that Friction pendulum-type seismic isolator is a device that attenuates seismic energy by friction and pendulum motion. The friction pendulum-type seismic isolator of this study is very easy to transport, install and maintain with light weight of metal by applying the slider using high strength engineering plastic. In addition, there is an advantage that the corrosion resistance is very excellent compared to the existing metal parts. However, there is concern about long-term durability by replacing metal materials. In this study, the frictional pendulum-type seismic isolator with EP was applied to compressive-shear test, repeated fatigue test, and ultimate load test after fatigue test, and analyzed the deformation and shear or properties after the test. As the results, the adequacy of long term fatigue durability was experimentally proven.

Prediction of Maneuverability of a Submarine at Surface Condition by Captive Model Test (구속모형시험을 통한 잠수함 선형의 수상 조건 조종성능 추정 연구)

  • Chang-Seop, Kwon;Dong-Jin, Kim;Young-Yeon, Lee;Yeon-Gyu, Kim;Kunhang, Yun;Sungrok, Cho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.6
    • /
    • pp.423-431
    • /
    • 2022
  • In this paper, the results of Planar Motion Mechanism (PMM) test for a 1/15 scaled model of the MARIN Joubert BB2 submarine is dealt with to derive the maneuvering coefficients for surface condition. For the depth of surface navigation, the top of the sail was exposed 0.46 m above the water surface in the model scale, and it corresponds to 6.9 m in the full scale. The resistance and self-propulsion tests were conducted, and the model's self-propulsion point was obtained for 1.328 m/s, which corresponded to 10 knots in the full scale. The maneuvering tests were performed at the model's self-propulsion point, and the maneuvering coefficients were obtained. Based on the maneuvering coefficients, a turning simulation was performed for starboard 30 degree of stern fins. The straight-line stability and control effectiveness in the horizontal plane were analyzed using the maneuvering coefficients and compared with the appropriate range. For the analysis of the neutral fin angle of the X-type stern fin, the stern fin test with drift angles was carried out. As a result, the flow straightening effect at lower and upper parts of the stern fin was discussed.

Variability in physical therapy protocols following total shoulder arthroplasty

  • Samuel Schick;Alex Dombrowsky;Jamal Egbaria;Kyle D. Paul;Eugene Brabston;Amit Momaya;Brent Ponce
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.267-275
    • /
    • 2023
  • Background: Physical therapy (PT) plays an important role in the recovery of function following anatomic total shoulder arthroplasty (aTSA). While several PT protocols have been published for these patients, there is no standardized protocol for aTSA rehabilitation. This lack of standardization may lead to confusion between patients and physicians, possibly resulting in suboptimal outcomes. This study examines how PT protocols provided by academic orthopedic surgery programs vary regarding therapeutic goals and activities following aTSA. Methods: PT protocols for aTSA available online from the Accreditation Council for Graduate Medical Education accredited orthopedic surgery programs were included for review. Each protocol was analyzed to evaluate it for differences in recommendation of length of immobilization, range of motion (ROM) goals, start time for and progression of therapeutic exercises, and timing for return to functional activity. Results: Of 175 accredited programs, 25 (14.2%) had protocols publicly available, programs (92%) recommended sling immobilization outside of therapy for an average of 4.4±2.0 weeks. Most protocols gave recommendations on starting active forward flexion (24 protocols, range 1-7 weeks), external rotation (22 protocols, range 1-7 weeks), and internal rotation (18 protocols, range 4-7 weeks). Full passive ROM was recommended at 10.8±5.7 weeks, and active ROM was 13.3±3.9 weeks, on average. ROM goals were inconsistent among protocols, with significant variations in recommended ROM and resistance exercise start times. Only 13 protocols (52%) gave recommendations on resuming recreational activities (mean, 17.4±4.4 weeks). Conclusions: Publicly available PT protocols for aTSA rehabilitation are highly variable. Level of evidence: IV.

Isokinetic Evaluation of the Trunk Flexors and Extensors of Operated Laminectomy & Disectomy Patients (요추간판 수핵탈출중 수술환자의 체간부 굴근 및 신근의 등속성 운동 평가)

  • Choi, Byung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.2
    • /
    • pp.951-961
    • /
    • 1996
  • Isokinetic exercise is dynamic, but the spped of movement must be regulated so that the resistance is in ratio to the force applied at each point throughout the full range of motion. The purpose of this study is to comparise with trunk flexors & extensors of isokinetic evaluation of pre-exercise and post-exercise in operated laminectomy & disectomy patients. 7 subjects were examined at $120^{\circ}$/sec and $60^{\circ}$/sec each 15 days. The results were as follows; 1. Peak torque of extensors on $60^{\circ}$/sec showed significant difference statistically(p<0.05), but peak torque of flexors on $60^{\circ}$/sec showed no significant difference statistically. 2. Trunk flexors/extensors ratio of peak torque of $60^{\circ}$/sec showed no significant difference ststistically. 3. Peak torque % B.W of extensors on $60^{\circ}$/sec showed significant difference statistically(p<0.05), but peak torque % B.W of flexors on $60^{\circ}$/sec showed no significant difference statistically. 4. TAE of extensors on $60^{\circ}$/sec showed significant difference statistically (p<0.05), but TAE of flexors on $60^{\circ}$/sec showed no significant difference. 5. Total work of flexors & extensors on $60^{\circ}$/sec showed significant difference statistically (p<0.05). 6. Average power of flexors & extensors on $120^{\circ}$/sec showed significant difference statistically(p<0.05). 7. Endurance ratio of flexors & extensors on $120^{\circ}$/sec showed no significant difference statistically. 8. Set total work of flexors & extensors on $120^{\circ}$/sec showed significant difference statistically(p<0.05). 9. TAE of extensors on $120^{\circ}$/sec showed significant difference statistically(p<0.05), TAE of flexors on $120^{\circ}$/sec showed no significant difference statistically. 10. Total work of flexors & extensors on $120^{\circ}$/sec showed significant difference statistically (p<0.05).

  • PDF

Effects of a Physical Therapy Program on Quality of Life, and Neck and Shoulder Disability in Patients With Head and Neck Cancer (두경부암 환자를 위한 물리치료 프로그램이 삶의 질, 목과 어깨의 장애 정도에 미치는 영향)

  • Do, Jung-Hwa;Jung, You-Hoi;Song, Eun-Ji;Jung, Soon-Yong;Cho, Young-Ki
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.36-46
    • /
    • 2013
  • This study examined the effects of a physical therapy program on quality of life (QOL), and neck and shoulder disability in head and neck cancer patients. The program included neck and shoulder range of motion (ROM) exercises, massage, progressive strengthening exercises, and stretching exercises. Sixteen patients who were assigned to an experimental group performed physical therapy for 40 minutes three times a week for eight weeks. Fifteen other patients were assigned to a control group who did not performed the physical therapy program. The European organization for research and treatment of cancer (EORTC QLQ-C30) and head and neck (EORTC QLQ-H&N) instruments, and the Neck Disability Index (NDI) were assessed before and after the rehabilitation program. The 40-minute program consisted of a 10-minute ROM exercise for the neck and shoulder, a 10-minute massage and 15-minute of progressive resistance exercises, followed by a five-minute stretching exercises. Statistically significant differences were noted for changes in global health, physical function in the EORTC QLQ-C30 and cancer related symptoms in the EORTC QLQ-H&N35 (p<.05). The NDI also showed significant differences (p<.05). Physical therapy may therefore benefit the physical aspects and QOL and improve neck and shoulder disability in patients with head and neck cancer.

Fabrication of flexible sponge electrodes using Ag nanowires (은나노와이어 함침 유연 스펀지 전극 제조)

  • Park, Kyoung Ryeol;Yoo, Sehoon;Ryu, Jeong Ho;Mhin, Sungwook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.5
    • /
    • pp.189-193
    • /
    • 2020
  • Recently, various methods for preparing a flexible electrode for implementing a wearable sensor have been introduced. Wearable sensors show similar tendency to use various polymer substrates, which provides elasticity suitable to the motion of human body. In this paper, a highly elastic silver nanowire based electrode was prepared on a sponge-based stretchable substrate, and electrical properties were evaluated. Silver nanowires were grown using a wet chemical synthesis, impregnated into a plasma-treated sponge, and then heat treated at a low temperature. In particular, the plasma surface treatment of the sponge enables uniform coating of silver nanowires. The flexible sponge electrode showed reliable electrical resistance changes over 160 repeated tensile-compression cycles.