• 제목/요약/키워드: Resistance effect

검색결과 6,812건 처리시간 0.744초

Effect of grain refinement on the performance of AZ80 Mg alloys during wear and corrosion

  • Naik, Gajanan M;Gote, Gopal D.;Narendranath, S;Kumar, S.S. Satheesh
    • Advances in materials Research
    • /
    • 제7권2호
    • /
    • pp.105-118
    • /
    • 2018
  • Magnesium and its alloys are attracted towards all engineering applications like automotive, marine, aerospace etc. due to its inherent high strength to weight ratio. But, extensive use of Mg alloys is limited to the current scenario because of low wear and corrosion resistance behavior. However, equal channel angular press is one of the severe plastic deformation technique which has been effective method to improve the wear and corrosion resistance by achieving fine grain structure. In this study, the effect of grain refinement on wear and corrosion resistance of AZ80 Mg alloys were investigated. The wear behavior of the coarse and fine-grained Mg alloys was examined through $L_9$ orthogonal array experiments in order to comprehend the wear behavior under varies control parameters. It was shown that ECAPed alloy increased the wear and corrosion resistance of the Mg alloy through the formation of fine grain and uniform distribution of secondary ${\beta}-phase$. Also, the performance of AZ80 Mg alloy for these changeswas discussed through SEM morphology.

CGS 잔골재를 사용한 콘크리트의 황산염 침투 저항성에 미치는 영향 (Effect of CGS Fine Aggregate on the Resistance to Sulfate Attack in Concrete)

  • 한준희;김수호;백성진;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.179-180
    • /
    • 2022
  • In this study, analyzed the effect of using CGS before and after the pre-treatment process as fine aggregate on the resistance to sulfate attack in concrete. As a result of the analysis, Although it showed a similar tendency to Plain (CS100), it is judged that it is necessary to analyze the resistance to sulfate attack due to the increase in immersion periods such as 180 days and 365 days.

  • PDF

PVA 섬유와 실리카흄 첨가가 알칼리 활성 슬래그의 염화물 침투 저항성에 미치는 영향 (Effect of PVA Fiber and Silica Fume Addition on Chloride Penetration Resistance of Alkali-Activated Slag)

  • 윤현노
    • 도시과학
    • /
    • 제12권2호
    • /
    • pp.13-18
    • /
    • 2023
  • This study investigates the effect of polyvinyl alcohol (PVA) fiber and silica fume addition on the chloride penetration resistance of alkali-activated slag. Silica fume was added to replace slag at the dosage of 0, 5, 10, and 20% by weight of the binder, while PVA fiber was added at the dosage of 0, 1, and 2% by volume of the mixture. Samples were synthesized via alkali activator with 1.0 of silicate modulus and cured at room temperature for 28 days. Compressive strength test, permeable voids volume test, water absorprtion test, and rapid chloride penetration test were conducted for measuring the charaterisitics of alkali-activaed slag. The results showed that increasing silica fume content up to 10% in alkali-activated slag improved compressive strength and chloride penetration resistance. Addition of PVA fibers up to 1% by volume enhanced strength and chloride penetration resistance, but exceeding this led to reduced strength and durability due to increased void formation in the matrix.

Laser 반사측정법을 이용한 상악전치부의 후방견인시 저항중심의 수직적 위치에 관한 실험적 연구 (EXPERIMENTAL STUDY OF THE VERTICAL LOCATION OF THE CENTERS OF RESISTANCE FOR MAXILLARY ANTERIOR TEETH DURING RETRACTION USING THE LASER REFLECTION TECHNIQUE)

  • 우재영;박영철
    • 대한치과교정학회지
    • /
    • 제23권3호
    • /
    • pp.375-389
    • /
    • 1993
  • The delivery of optimal orthodontic treatment is greatly influenced by a clinician's ability to predict and control tooth movement achieved by applying known force systems to the dentition. It is important to determine the location of the center of resistance of a tooth or group of teeth to better understand the nature of their displacement characteristics under the various force levels. The purpose of this study was to define the location of the centers of resistance of various units of the upper anterior segment for lingually directed 100gm and 200gm force in a dry human skull. The units investigated were composed of four incisors and six anterior teeth. In addition, the effect of change in force magnitude on the location of the center of resistance of these units was investigated. The laser reflection technique was used to measure the initial displacements of the consolidated teeth under loading. The results were as follows: 1. The instantaneous center of resistance for the four anterior teeth was located vertically between level 4 and level 5-that is, at $37.4\%$ apical to the cementoenamel junction level. 2. The instantaneous center of resistance for the six anterior teeth was located vertically just beneath level 5-that is, at $50.3\%$ apical to the cementoenamel junction level. 3. Increasing force levels had little effect on the location of the center of resistance of a given unit. 4. The location of the instantaneous center of resistance shifted apically as the number of dental units consolidated increased.

  • PDF

AC8A 알루미늄 합금 주조재의 열처리에 의한 특성 평가(II) (Evaluation of the Characteristics of the Aluminum Alloy(AC8A) Casting Material by Heat Treatment(II))

  • 문경만;정재현;이명훈;백태실
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.29-36
    • /
    • 2016
  • Aluminum alloys have been widely used in engine materials, cold & hot-water storage vessels and piping etc., Furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston for various vehicles because of its properties of temperature, wear and corrosion resistance. Therefore, it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and to prolong its lifetime. In previous paper, the effect of solution($510^{\circ}C$:4hrs) and tempering($190^{\circ}C$: 16, 24, and 36 hrs)heat treatments to corrosion resistance and hardness were investigated using electrochemical method. In this study, in order to examine completely the effect of the tempering hours to hardness variation and corrosion resistance, the results of solution($510^{\circ}C$:4hrs) and tempering($190^{\circ}C$: 2, 4, 8 and 12hrs)heat treatments to hardness and corrosion resistance were investigated using electrochemical method. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment. Furthermore, the corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. And the tempering heat treatment temperature at $190^{\circ}C$ for 8 hrs exhibited the highest value of the hardness and also indicated the highest corrosion current density. However, the values of hardness and corrosion current density was again increasingly decreased with increasing of tempering hours than 8 hrs, Consequently, it is suggested that decision of the optimum. tempering hours is very important to improve the corrosion or wear resistance.

차체 외판 부품의 덴트 특성 향상을 위한 알루미늄 판재의 성형조건에 관한 연구 (Forming Condition for Automotive Body Outer Panel using Aluminum Alloy Sheet for Improved Dent Resistance)

  • 고세진;김태정;김익수
    • 소성∙가공
    • /
    • 제20권6호
    • /
    • pp.420-426
    • /
    • 2011
  • Dent resistance is determined by both shape characteristics, i.e., local radius of curvature and sheet thickness, and material properties such as yield strength. This work presents results of a study on the effect of work hardening and bake hardening on dent resistance of aluminum alloy sheet parts by considering the forming condition and baking temperature.

도전성 팽창 접지저감재의 접지저항 저감 효과 (The Ground Resistance Reduction Effect of o Conductive Expansion Ground Resistance Reducing Material)

  • 김종욱;김경철;최종기;강민규;백남웅
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.155-161
    • /
    • 2008
  • 접지시스템은 고장전류나 상시 전류를 낮은 저항의 대지로 흘러 보낸다. 접지전극 주변에 접지저감재를 매설하면 접촉 면적을 증가시켜 낮은 접지저항을 얻을 수 있다. 접지전극의 접촉면적을 확대시키면 접지저항값이 낮아진다는 특성을 이용하여 접지 시공시 팽창 특성을 가진 도전성 팽창 접지저감재를 개발하였다. 본 논문에서는 실험을 통하여 도전성 팽창 접지저감재가 일반 접지저감재보다 접지저항 저감 효과가 뛰어남을 검증하였다.

Canopy를 고려한 대기오염물질의 건성침적모델에 관한 연구 (A Study on the Dry Deposition Model of Air Pollutants Considering Canopy Effect)

  • 이화운;박종길
    • 한국환경과학회지
    • /
    • 제4권2호
    • /
    • pp.151-158
    • /
    • 1995
  • A numerical model has been developed to predict the deposition of air pollutants considering canopy effect. In this model, the deposition velocity is calculated using the deposition resistances(aerodynamic resistance, viscosity resistance, surface resistance). Using the results, a comparative study was made between the model calculation and observation results. The calculated daily variation of deposition resistances and in daytime most of the model cases are well agreed with observation results, and a slight difference was found in nighttime. From the results, it is suggested that the present model is capable of estimating the deposition velocity of air Pollutants considering characteristics of canopy layer.

  • PDF

Fabrication of W-Cu Composite by Resistance Sintering under Ultrahigh Pressure

  • Kwon, Y.S.;Kim, J.S.;Zhou, Z.J.
    • 한국분말재료학회지
    • /
    • 제10권3호
    • /
    • pp.181-185
    • /
    • 2003
  • Resistance sintering under ultra-high pressure if developed to fabricate W-Cu composite containing 5 to 80v/o copper. The consolidation was carried out under pressure of 6 to 8 GPa and input power of 18 to 23 kW for 50 seconds. The densification effect and microstructure of these W-Cu composites are investigated. The effect of W particle size on ,sintering density was also studied. The micro hardness was measured to evaluate the sintering effect.

345kV 지중 및 혼합 송전계통에서의 개폐 과전압 해석 (Analysis of Switching Overvoltage in 345kV Underground and Combined Transmission Systems)

  • 정채균;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.713-721
    • /
    • 2003
  • This paper analyzes the switching overvoltage occurred on 345kV underground power cable system as well as combined transmission system using EMTP. Cable length and closing time, preinsertion resistance have effect on switching overvoltage. Therefore, this paper analyzes the switching overvoltage occurred on conductor and sheath with change of those parameters. Specially, the cross bonding position becomes discontinuity point because of the difference between surge impedance of metal sheath and that of lead cable. Thus, the transmission and the reflection of traveling wave complexly occur at this connection point. According to these influences, voltage between sheath and earth as well as voltage between joint boxes rise. Time to crest point of switching overvoltage is longer than lightning overvoltage. Even though the voltage induced by switching surge is smaller than lightning surge, that voltage may have serious effect on the metal sheath. Therefore, this paper also analyses the reduction effect of switching overvoltage when the preinsertion resistance of circuit breaker is considered.