• Title/Summary/Keyword: Resin-modified glass ionomer cement

Search Result 52, Processing Time 0.031 seconds

Change in shear bond strength of orthodontic brackets using self-etching primer according to adhesive types and saliva contamination (Self-etching primer를 사용하여 교정용 브라켓 접착 시 접착제와 타액오염에 따른 전단결합강도 변화)

  • Nam, Eun-Hye;Yoon, Young-Ah;Kim, Il-Kyu
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.433-442
    • /
    • 2005
  • The purpose of this study was to evaluate and compare the shear bond strength of orthodontic brackets depending on the variety of adhesives and whether saliva exists, by using self-etching primer (SEP). Groups were divided according to the type of adhesive into resin adhesive (Trans bond XT) and resin-modified glass ionomer cement (Fuji Ortho LC). One group of resin adhesive used XT primer after etching with 37% phosphoric acid, and the other group used self-etching primer. One group of resin-modified glass ionomer cement only used etching for bonding, and the other group used SEP. Each of the groups were also classified by whether saliva was contaminated or not. and then the shear bond strength was measured. The results showed that when using resin adhesive, the shear bond strength of SEP was lower than the XT primer. In the resin-modified glass ionomer cement groups, the shear bond strength which depends on the priming method, did not have a meaningful difference statistically When saliva was contaminated, the group which used SEP, regardless of the adhesive variety, had a greater shear bond strength than the normal priming group. From these results, SEP showed a shear bond strength that is possible to be used clinically, regardless of the adhesive variety. It can especially be clinically useful to use SEP to bond brackets even on tooth surfaces contaminated with saliva, because it offers the appropriate bonding strength as well as shorter treatment time and easy application.

Fluoride Release of Several Types of Fluoride-Containing Restorative Materials According to Fluoride Concentration in Toothpaste (치약 내 불소농도에 따른 수종의 불소함유 수복재의 불소 방출량)

  • Chungho, Lee;Jewoo, Lee;Jiyoung, Ra
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.2
    • /
    • pp.197-205
    • /
    • 2022
  • This study was conducted to investigate the fluoride release of fluoride-containing restorative materials in fluoride recharging according to the concentration of fluoride toothpaste used in Korea. Samples of glass ionomer cement, resin-modified glass ionomer cement, alkasite restorative material, and composite resin were prepared and fluoride release was measured on days 1, 3, 7, 14, 21, 28. Thereafter, fluoride-free, 500 ppm, and 1450 ppm fluoride toothpaste was applied to each restorative materials, and the fluoride release was measured on days 1, 3, 7. Glass ionomer cement showed the highest cumulative fluoride release until the 7th day of measurement, and from the 14th day onwards, the resin-modified glass ionomer cement showed the highest cumulative fluoride release, but there was no significant difference. When restorative material groups were recharged with 500 ppm of fluoride toothpaste, the fluoride release was significantly higher only for the alkasite restorative material compared to the fluoride-free toothpaste group (p < 0.017). When restorative material groups were recharged with 1450 ppm of fluoride toothpaste, the fluoride release was significantly higher in all restorative groups compared to the fluoride-free toothpaste group (p < 0.017).

BONDING OF RESIN INLAY TO GLASS-IONOMER BASE WITH VARIOUS TREATMENTS ON INLAY SURFACE (내표면 처리에 따른 레진 인레이와 글래스아이오노머 베이스간의 접착)

  • Jang, Byung-Sung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.399-406
    • /
    • 2000
  • The effect of inlay surface treatment on bonding was investigated when resin inlay was bonded to resin-modified glass-ionomer base with resin cement. For the preparation of glass-ionomer base, resin-modified glass-ionomer cement (Fuji II LC, GC Co., Japan) was filled in class I cavities of 7mm in diameter and 2mm in depth made in plastic molds. Eighty eight resin inlay specimens were made with Charisma$^{(R)}$ (Kulzer, Germany) and then randomly assigned to the four different surface treatment conditions: Group I, $50{\mu}m$ aluminium oxide sandblasting and silane treatment ; Group II, silane treatment alone ; Group III, sandblasting alone, and Group IV (control), no surface treatment. After a dentin bonding agent with primer (One-Step$^{TM}$, Bisco Inc., IL., U.S.A.) was applied to bonding surface of resin inlay and base, resin inlay were cemented to glass-ionomer base with a resin cement (Choice$^{TM}$, Bisco Inc., IL., U.S.A.). Shear bond strengths of each specimens were measured using Instron universal testing machine (4202 Instron, lnstron Co., U.S.A.) and fractured surfaces were examined under the stereoscope. Statistical analysis was done with one-way ANOVA and Dunkan's multiple range test. The results were as follows: 1. Sandblasting and silane treatment provided the greatest bond strength(10.56${\pm}$1.95 MPa), and showed a significantly greater bond strength than sandblasting alone or no treatment (p<0.05). 2. Silane treatment provided a significantly greater bond strength(9.77${\pm}$2.04 MPa) than sandblasting alone or no treatment (p<0.05). However, there was no significant difference in bond strength between sandblasting treatment and silane one (p>0.05). 3. Sandblasting alone provided no significant difference in bond strength from no treatment (p>0.05). 4. Stereoscopic examination of fractured surface showed that sandblasting and silane treatment or silane treatment alone had more cohesive failure mode than adhesive failure mode. 5. In relationship between shear bond strength and failure mode, cohesive failure occurred more frequently as bond strength increased.

  • PDF

MICROLEAKAGE OF COMPOMER IN CLASS II CAVITY (제 2 급 와동에 충전된 Compome의 미세누출에 관한 연구)

  • Im, Jae-Hun;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.346-355
    • /
    • 1999
  • To evaluate the micro leakage of compomer, 4 materials were divided into 4 groups of 15 cavities each.(Group 1: Z-100, Group 2: Dyarct AP, Group 3: Fuji II LC, Group 4: Compoglass) After the class II cavities were prepared using carbide bur No. 553, all specimen were restored by incremental filling technique. In group 3, Z-100 was filled with a base of a light curing glass-ionomer. After 7 days, all specimens were thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 500 cycles, followed by placement in 50% silver nitrate dye for 2 hours at $37^{\circ}C$. After rinsed in distilled water, these teeth were immersed in photodeveloping solution and exposed to fluorescent light for 6 hours. Teeth were then washed in distilled water to remove the photodeveloping solution, sectioned mesio-distally and evaluated. The results were as follows : 1. In the cervical portion, there was significant difference between Fuji II LC and other groups(Z-100, Dyract AP, Compoglass), Fuji II LC had the least value.(p<0.05) 2. In the cervical portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. 3. In the occlusal portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. From the results above, In enamel, microleakage of compomer such as Dyract AP and Compoglass resemble to that of composite resin. It is thought that it is due to characteristics of composite resin portion of compomer. But in dentin, microleakage of compomer is higher than that of resin modified glass ionomer cement, it is thought that in compomer, acid-base reaction is not developed with dentin.

  • PDF

A STUDY ON THE RELATIVE SHEAR BOND STRENGTHS OF SOME ADHESIVE RESTORATIVE MATERIALS TO PRIMARY ENAMEL AND DENTIN (수종 접착성 수복재의 유치 법랑질과 상아질에 대한 상대적 접착력의 비교연구)

  • Kim, Seung-Mee;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.237-245
    • /
    • 2000
  • For the purpose of comparing the bond strengths of some tooth adhesive restoration materials on primary enamel and dentin, 4 kinds (7 brands) of restorative materials including a composite resin (Z 100), a conventional glass ionomer cement (Chem-Flex), 2 brands of resin-modified glass ionomer cements (Fuji II LC-I, Vitremer), and 3 brands of compomers(Dyract AP, F2000, Compoglass) were investigated using UTM for measuring the shear bond strengths. Additionally the failure modes were examined by histologically observing the fractured surfaces of each specimen. The following results were obtained. 1. The shear bond strengths of Z 100 to the primary enamel were higher than those of other experimental materials except Fuji II LC-I, which showed significantly higher bond strength than Chem-Flex or Vitremer (P<0.05). 2. The shear bond strengths of Z 100 to the primary dentin were higher than those of other experimental materials except Dyract AP and Fuji II LC-I, both of which showed significantly higher shear strength than Chem-Flex or Vitremer (P<0.05). 3. The shear bond strengths of all restorative materials except Dyract AP showed relatively higher values to enamel surface than to dentin surface. In Dyract AP, the reverse was true significantly. 4. All materials examined showed cohesive failures except some Chem-Flex and Vitremer, which showed adhesive failures.

  • PDF

In vitro cytotoxicity of four kinds orthodontic band cements (수종 치과 교정용 밴드 시멘트의 세포독성에 관한 실험적 연구)

  • Lee, Won-Chul;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.351-362
    • /
    • 2004
  • Orthodontic band cements are widely used in the fields of orthodontics, but they are commonly known as cytotoxic material. Within an oral cavity several ions and components are released from orthodontic band cements, thus causing inflammation or injury to the Periodontal tissue. Therefore, it is very important to estimate the biocompatibility of orthodontic band cements. The purpose of this study was to assess the cytotoxic effect of orthodontic band cements to HGF cells. A zinc phosphate cement, a glass ionomer, a resin modified glass ionomer, and compomer were used to evaluate three cytotoxicity assays: cell proliferation assay, MTT assay, and agar ovelay assay The results were as follows: 1. In the cell proliferation assay, Gl>ZPC, RMGI, RMGI24, GI24>compomer24, ZPC24, compomer>metal ring lined up in order of cytotoxicity 2. In the MTT assay, GI>ZPC, RMGI>GI24>ZPC24, compomer, metal ring, RMGI24, compomer24 lined up in order of cytotoxicity. 3. In the agar overlay test, GI>GI24, ZPC, ZPC24, RMGI>RMGI24, compomer, compomer24, metal ring lined up in order of cytotoxicity.

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF

Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

  • Safari, Sina;Ghavam, Fereshteh Hosseini;Amini, Parviz;Yaghmaei, Kaveh
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (${\alpha}=.05$). RESULTS. The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION. Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

Effect of Nano-filled Protective Coating on Microhardness and Wear Resistance of Glass-ionomer Cements (나노필러가 함유된 표면보호재가 글라스 아이오노머 시멘트의 미세경도와 마모저항성에 미치는 효과)

  • Ryu, Wonjeong;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.226-232
    • /
    • 2019
  • The purpose of this study was to investigate the effect of adding a protective coating on the microhardness and wear resistance of glass ionomer cements (GICs). Specimens were prepared from GIC and resin-modified GIC (RMGI), and divided into 3 groups based on surface protection: (1) no coating (NC), (2) Equia coat coating (EC), and (3) un-filled adhesive coating (AD). All specimens were then placed in distilled water for 24 h. Surface hardness (n = 10) was evaluated on a Vickers hardness testing machine. Wear resistance (n = 10) was evaluated after subjecting the specimen to thermocycling for 10,000 cycles using a chewing simulator. Data were analyzed using a one-way ANOVA and the Kruskal-Wallis test. Surface hardness was highest in the NC groups, followed by the EC and AD groups. The wear depth of GI + NC was significantly higher than that of all RMGI groups. EC did not significantly lower the wear depth compared to AD. Based on these results, it was concluded that although EC does not increase the surface microhardness of GIC, it can increase the wear resistance.

Effect of casein phosphopeptide-amorphous calcium phosphate on fluoride release and micro-shear bond strength of resin-modified glass ionomer cement in caries-affected dentin

  • Agob, Jamila Nuwayji;Aref, Neven Saad;Al-Wakeel, Essam El Saeid
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.45.1-45.11
    • /
    • 2018
  • Objectives: This study was conducted to evaluate fluoride release and the micro-shear bond strength of resin-modified glass ionomer cement (RMGIC) in casein phosphopeptide-amorphous calcium phosphate (CPP-ACP)-remineralized caries-affected dentin (CAD). Materials and Methods: Exposed dentin surfaces of 30 human third molar teeth were divided into 2 equal groups for evaluating fluoride release and the micro-shear bond strength of RMGIC to CAD. Each group was subdivided into 3 equal subgroups: 1) control (sound dentin); 2) artificially demineralized dentin (CAD); 3) CPP-ACP remineralized dentin (remineralized CAD). To measure fluoride release, 15 disc-shaped specimens of RMGIC (4 mm in diameter and 2 mm in thickness) were bonded on one flat surface of the dentin discs of each group. Fluoride release was tested using ion chromatography at different intervals; 24 hours, 3, 5, 7 days. RMGIC micro-cylinders were built on the flat dentin surface of the 15 discs, which were prepared according to the assigned group. Micro-shear bond strength was measured after 24 hours water storage. Data were analyzed using 1- and 2-way analysis of variance and the post hoc least significant difference test (${\alpha}=0.05$). Results: Fluoride detected in solutions (at all intervals) and the micro-shear bond strength of RMGIC bonded to CPP-ACP-remineralized dentin were significantly higher than those bonded to artificial CAD (p < 0.05). Conclusions: Demineralized CAD consumes more fluoride released from RMGIC into the solution for remineralization than CPP-ACP mineralized dentin does. CPP-ACP increases the micro-shear bond strength of RMGIC to CAD.