• 제목/요약/키워드: Resin matrix

검색결과 458건 처리시간 0.028초

다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구 (A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods)

  • 김두열;조인호
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

The effect of silane and universal adhesives on the micro-shear bond strength of current resin-matrix ceramics

  • Sarahneh, Omar;Gunal-Abduljalil, Burcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.292-303
    • /
    • 2021
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of silane and universal adhesive applications on the micro-shear bond strength (µSBS) of different resin-matrix ceramics (RMCs). MATERIALS AND METHODS. A total of 120 slides (14 × 12 × 1 mm) were produced from 5 different RMC materials (GC Cerasmart [GC]; Brilliant Crios [BC]; Grandio blocs [GB]; Katana Avencia [KA]; and KZR-CAD HR 2 [KZR]) and sandblasted using 50 ㎛ Al2O3 particles. Each RMC material was divided into six groups according to the surface conditioning (SC) method as follows: control (G1), silane primer (G2), silane-free universal adhesive (G3), silane-containing universal adhesive (G4), silane primer and silane-free universal adhesive (G5), and silane primer and silane-containing universal adhesive (G6). Three cylindric specimens made from resin cement (Bifix QM) were polymerized over the treated surface of each slide (n = 12). After thermal cycling (10000 cycles, 5 - 55℃), µSBS test was performed and failure types were evaluated using a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey tests (α = .05). RESULTS. µSBS values of specimens were significantly affected by the RMC type and SC protocols (P < .001) except the interaction (P = .119). Except for G2, all SC protocols showed a significant increase in µSBS values (P < .05). For all RMCs, the highest µSBS values were obtained in G4 and G6 groups. CONCLUSION. Only silane application did not affect the µSBS values regardless of the RMC type. Moreover, the application of a separate silane in addition to the universal adhesives did not improve the µSBS values. Silane-containing universal adhesive was found to be the best conditioning method for RMCs.

이상계내에서 고정화리파제에 의한 트리글리세리드의 가수분해 (Hydrolysis of Triglyceride in Two Phase System Using Immobilized Lipase)

  • 권대영;김기혁;이준식
    • 한국미생물·생명공학회지
    • /
    • 제15권2호
    • /
    • pp.122-128
    • /
    • 1987
  • Candida rugosa와 Rhizopus arrhizus 리파제를 photocrosslinkable resin prepolymer에 고정화시켜서 이소옥탄을 유기용매로 사용한 이상계를 이용해서 유지분해 및 에스테르교환 반응을 보고자했다. Dioctylsulfosuccinate가 가장 좋은 surfactant였다. 소수성 젤인 ENTP-3000에 고정된 리파제가 좋은 활성을 나타냈고 친수성 젤인 ENT-4000에 고정된 리파제가 유기용매에 대해 안정했다. 고정화 matrix의 소수성이 증가될수록Vm(app)는 증가되었으나 Km(app)는 거의 일정했다. 리파제의 최적 pH는 소수성 젤인 ENTP-3000에 고정된 경우 C. rugosa와 R. arrhizus 리파제에 대해서 각각 6.0과 6.5였으나, 친수성 젤에 고정된 리파제는 짧은 시간 반응에는 pH에 크게 영향을 받지 않았으나 긴 시간 동안 반응시킬 때는 역시 pH6.0과 6.5에서 각각 C. rugosa와 R. arrhizus 리파제가 높은 양의 지방산을 분해시켰다. 리파제를 entrapment 시키면 열안정성이 증가됨을 알 수 있었다.

  • PDF

전도성 구리충전제/에폭시수지 복합체의 전기적 특성 (Electrical Properties of Conductive Copper Filler/Epoxy Resin Composites)

  • 이정은;박영희;오승민;임덕점;오대희
    • 한국응용과학기술학회지
    • /
    • 제30권3호
    • /
    • pp.472-479
    • /
    • 2013
  • The conductive polymer composites recently became increasingly to many fields of industry due to their electrical properties. To understand these properties of composites, electrical properties were measured and were studied relatively. Electrical conductivity measurements showed percolation phenomena. Percolation theories are frequently applied to describe the insulator-to-conductor transitions in composites made of a conductive filler and an insulating matrix. It has been showed both experimentally and theoretically that the percolation threshold strongly depends on the aspect ratio of filler particles. The critical concentration of percolation formed is defined as the percolation threshold. This paper was to study epoxy resin filled with copper. The experiment was made with vehicle such as epoxy resin replenished with copper powder and the study about their practical use was performed in order to apply to electric and electronic industry as well as general field. The volume specific resistance of epoxy resin composites was 3.065~13.325 in using copper powder. The weight loss of conductive composites happened from $350^{\circ}C{\sim}470^{\circ}C$.

Biofilm formation on denture base resin including ZnO, CaO, and TiO2 nanoparticles

  • Anwander, Melissa;Rosentritt, Martin;Schneider-Feyrer, Sibylle;Hahnel, Sebastian
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.482-485
    • /
    • 2017
  • PURPOSE. This laboratory study aimed to investigate the effect of doping an acrylic denture base resin material with nanoparticles of ZnO, CaO, and $TiO_2$ on biofilm formation. MATERIALS AND METHODS. Standardized specimens of a commercially available cold-curing acrylic denture base resin material were doped with 0.1, 0.2, 0.4, or 0.8 wt% commercially available ZnO, CaO, and $TiO_2$ nanopowder. Energy dispersive X-ray spectroscopy (EDX) was used to identify the availability of the nanoparticles on the surface of the modified specimens. Surface roughness was determined by employing a profilometric approach; biofilm formation was simulated using a monospecies Candida albicans biofilm model and a multispecies biofilm model including C. albicans, Actinomyces naeslundii, and Streptococcus gordonii. Relative viable biomass was determined after 20 hours and 44 hours using a MTT-based approach. RESULTS. No statistically significant disparities were identified among the various materials regarding surface roughness and relative viable biomass. CONCLUSION. The results indicate that doping denture base resin materials with commercially available ZnO, CaO, or $TiO_2$ nanopowders do not inhibit biofilm formation on their surface. Further studies might address the impact of varying particle sizes as well as increasing the fraction of nanoparticles mixed into the acrylic resin matrix.

복합(複合)레진의 표면연마(表面硏磨)에 관(關)한 실험적(實驗的) 연구(硏究) (EXPERIMENTAL STUDY OF THE SURFACE FINISHINGS ON THE COMPOSITE RESIN SURFACES)

  • 김부랑;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.97-106
    • /
    • 1982
  • The purpose of this study was to evaluate the effect of different polishing procedures on the surfaces of composite resins. Two-paste type comosite restorative resin (Hipol) was selected for this study. 70 cavities prepared on the plaster-stone dies, 6mm in diameter and 2mm in depth, was filled with composite resin according to the manufacturer's specifications and by polymerizing against mylar strips. The polymerized composite resin specimens were polished (surface finished) by using 6 polishing devices; white stones, diamond finishing points, 12-fluted carbide finishing burs, green stones, sand paper disks, and Quasite rubber disk after polished with sand paper disks and green stones. A profilometer (Bendix type) was used to record in microinches the surface roughness of each surface finished composite resin specimens. The results were as follows. 1. The best finished surface that can be obtained is a surface formed by the mylar matrix strip 2. The white stones produced the smoothest surface in the experimental group. 3. The green stones produced the roughest surface in the experimental group. 4. It was proved that the gradual use of finishing instruments from a rough one to fine ones reduced the surface roughness.

  • PDF

BCB Resin-BNT 복합 기판 소재의 제조 및 특성 평가 (Preparation and Characterization of BCB Resin-BNT Composite Substrate Materials)

  • 김운용;전명표;조정호;김병익;이용현;명성재;한익현;신동욱
    • 한국세라믹학회지
    • /
    • 제44권5호
    • /
    • pp.179-183
    • /
    • 2007
  • BCB $Resin-BaNd_2Ti_4O_{12}$(BNT) composites with BNT contents were prepared by tape casting method and epoxy resin-BNT composites were prepared by using heating press. Their dielectric properties and microstructures were investigated. The dielectric properties such as dielectric constant and dielectric loss at 1 MHz for epoxy resin-BNT composites and BCB resin-BNT composites are improved with an increase of BNT volume fraction. The dielectric constant of the Epoxy-BNT composite increased from 5.9 to 7.8 as the volume fraction of BNT increased from 15 to 25. The dielectric constant of the BCB-BNT composite increased from 9.1 to 15.5 as the volume fraction of BNT increased from 30 to 50. The dielectric behavior of BCB-BNT system can be explained by Lichtenecker's equation. The dielectric constant of epoxy resin-BNT composite is smaller than that of BCB resin-BNT composite. These results are considered to be related with the dispersion of BNT filler in polymer matrix from the result of SEM photograph.

Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements

  • Sadighpour, Leyla;Geramipanah, Farideh;Ghasri, Zahra;Neshatian, Mehrnoosh
    • Restorative Dentistry and Endodontics
    • /
    • 제43권4호
    • /
    • pp.40.1-40.10
    • /
    • 2018
  • Objectives: This study evaluated the microtensile bond strength (${\mu}TBS$) of polymer-ceramic and indirect composite resin with 3 classes of resin cements. Materials and Methods: Two computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated polymer-ceramics (Enamic [ENA; Vita] and Lava Ultimate [LAV; 3M ESPE]) and a laboratory indirect composite resin (Gradia [GRA; GC Corp.]) were equally divided into 6 groups (n = 18) with 3 classes of resin cements: Variolink N (VAR; Vivadent), RelyX U200 (RXU; 3M ESPE), and Panavia F2 (PAN; Kuraray). The ${\mu}TBS$ values were compared between groups by 2-way analysis of variance and the post hoc Tamhane test (${\alpha}=0.05$). Results: Restorative materials and resin cements significantly influenced ${\mu}TBS$ (p < 0.05). In the GRA group, the highest ${\mu}TBS$ was found with RXU ($27.40{\pm}5.39N$) and the lowest with VAR ($13.54{\pm}6.04N$) (p < 0.05). Similar trends were observed in the ENA group. In the LAV group, the highest ${\mu}TBS$ was observed with VAR ($27.45{\pm}5.84N$) and the lowest with PAN ($10.67{\pm}4.37N$) (p < 0.05). PAN had comparable results to those of ENA and GRA, whereas the ${\mu}TBS$ values were significantly lower with LAV (p = 0.001). The highest bond strength of RXU was found with GRA ($27.40{\pm}5.39N$, p = 0.001). PAN showed the lowest ${\mu}TBS$ with LAV ($10.67{\pm}4.37N$; p < 0.001). Conclusions: When applied according to the manufacturers' recommendations, the ${\mu}TBS$ of polymer-ceramic CAD/CAM materials and indirect composites is influenced by the luting cements.

Characteristics according to the Amount of HAp Added in Resin for Tooth Repair

  • Hwang, Sungu;Lim, Jinhyuck;Ryu, Suchak
    • 한국세라믹학회지
    • /
    • 제56권6호
    • /
    • pp.521-525
    • /
    • 2019
  • A study was conducted to investigate the possibility of a composite material containing a composite resin as a matrix and hydroxyapatite (HAp) powder as a substitute material for tooth repair. As the content of HAp increased, hardness value (111.9 HV at 9%) increased and flexural strength (73.3 MPa at 9%) decreased. Observation of the microstructure after immersion in a simulated body fluid (SBF) solution confirmed a dense structure due to mutual coagulation and curing. It was thought that fine HAp recrystals were formed with the lapse of time, and they were entangled to form a condensation structure and had a dense structure. In addition, since the activity was shown by the ion migration on the surface of a tooth, it was highly likely that a biocompatible bond occurred during tooth contact. Therefore, it could be used as a substitute material for tooth repair.

전기 기기용 봉지 및 함침 에폭시 복합 재료의 내열성 및 절연파괴 특성 개선에 관한 연구 (A study on the improvement of thermostability and dielectric breakdown strength for packaging and impregnating epoxy composite materials for electrical machines and apparatus)

  • 김명호;김재환
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권6호
    • /
    • pp.527-533
    • /
    • 1994
  • In this study, it was studied on dielectric breakdown strength and thennostability properties due to the structure variation of matrix resin and treatment of coupling agent of epoxy insulating materials. The interpenetrating network structure was formed by simultaneous heating curing the epoxy resin with single network structure and the methacrylic acid resin. Also inner structure was observed and the glass transition temperature was measured on these three type specimens. Dielectric breakdown properties were investigated by applying DC, AC and impulse voltage. As a result, the glass transition temperature and the dielectric breakdown strength of specimen with interpenetrating network structure was more higher than another two type specimens.

  • PDF