• 제목/요약/키워드: Resin flow

검색결과 389건 처리시간 0.022초

Influence of 10-Methacryloyloxydecyl Dihydrogen Phosphate on Cellular Senescence in Osteoblast-Like Cells

  • Ju Yeon Ban;Sang-Im Lee
    • 치위생과학회지
    • /
    • 제23권4호
    • /
    • pp.264-270
    • /
    • 2023
  • Background: Resin-based dental materials release residual monomers or other substances from incomplete polymerization into the oral cavity, thereby causing adverse biological effects on oral tissue. 10-Methacryloyloxydecyl dihydrogen phosphate (10-MDP), an acidic monomer containing dihydrogen phosphate and methacrylate groups, is the most commonly used component of resin-based dental materials, such as restorative composite resins, dentin adhesives, and resin cements. Although previous studies have reported the cytotoxicity and biocompatibility in various cultured cells, the effects of resin monomers on cellular aging have not been reported to date. Therefore, this study aimed to investigate the effects of the resin monomer 10-MDP on cellular senescence and inflamm-aging in vitro. Methods: After stimulation with 10-MDP, MC3T3-E1 osteoblast-like cells were examined for cell viability by WST-8 assay and reactive oxygen species (ROS) production by flow cytometry. The protein and mRNA levels of molecular markers of aging were determined by western blotting and RT-PCR analysis, respectively. Results: Treatment with 0.05 to 1 mM 10-MDP for 24 hours reduced the survival of MC3T3-E1 cells in a concentration-dependent manner. The intracellular ROS levels in the 10-MDP-treated experimental group were significantly higher than those in the control group. 10-MDP at a concentration of 0.1 mM increased p53, p16, and p21 protein levels. Additionally, an aging pattern was observed with blue staining due to intracellular senescence-associated beta-galactosidase activity. Treatment with 10-MDP increased the levels of tumor necrosis factor-α, interleukin (IL)-1β, IL-6 and IL-8, however their expression was decreased by mitogen-activated-protein-kinase (MAPK) inhibitors. Conclusion: Taken together, these results suggest that the exposure of osteoblast-like cells to the dental resin monomer 10-MDP, increases the level of cellular senescence and the inflammatory response is mediated by the MAPK pathway.

First Report of Pitch Canker Disease on Pinus rigida in Korea

  • Lee, Jong-Kyu;Lee, Sang-Hyun;Sung-II Yang;Lee, Yin-Won
    • The Plant Pathology Journal
    • /
    • 제16권1호
    • /
    • pp.52-54
    • /
    • 2000
  • Pitch canker of Pinus rigida, caused by Fusarium subglutinans f. sp. pini, was first noticed in Inchon, Korea, and is now being spread into other plantations of pines. Typical symptoms re resin flows from canders on the shoots, branches, and trunks, and resin-soaking of the sap wood under the bark. Pathogenic fungi were isolated from the infected shoots, branches, and sees on Fusarium-selective medium. Mycelial growth and microscopic characteristics were examined. Pathogenicity test was carried out by inoculating four common species of pines (P. rigida, P. densiflora, P. thunbergii, and P. koraiensis) in Korea. P. rigida and P. thunbergii showed symptoms identical to those of naturally infected trees, while P. densiflora and P. koraiensis remained free symptomless.

  • PDF

유동성 복합레진의 마모저항성에 관한 연구 (A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS)

  • 윤연희;김정욱;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.217-225
    • /
    • 2002
  • 시술시간을 줄이는데 유리한 재료인 유동성 복합레진을 유구치부에 사용하려고 고려할 때 중요한 물성 중 하나는 마모저항성이다. 이 연구의 목적은 유동성 복합레진의 마모저항성을 일반복합레진의 마모저항성과 비교하는 것이다. 실험에 사용된 유동성 복합레진으로 1군에서는 Arabesk flow (VOCO, Germany) 2군에서는 Tetric flow (Vivadent, Liechtenstein) 3군에서는 Aeliteflow (Bisco, U.S.A.), 4군에서는 Filtek flow (3M Dental Co, U.S.A)을 사용하였으며 대조군으로 사용한 5군의 복합레진은 Z100 (3M Dental Co, U.S.A)이었다. 시편들(n=10)은 두께 2mm, 지름 5mm의 원통모양으로 제작하여 마모시험 전 $37^{\circ}C$의 증류수에서 7일 동안 담가 놓았다. 제1소구치와 레진시편을 MTS 시스템에서 2Hz로 50,000회 접촉, 마모시켰다. 마모시험시 lateral excursion은 0.4mm, 교합력은 2-100N의 조건이었다. 마모시험후 마모된 부피, 최대마모깊이, 재료자체의 표면경도를 측정하였고 마모 되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰하였으며 다음과 같은 결과를 얻었다. 1. 마모된 부피는 3군에서 가장 적었고 4군에서 가장 많았으며 3군<1군<2군<5군<4군의 순서로 증가하였다. 2. 3군, 1군, 2군은 5군이나 4군에 비해 통계적으로 유의하게 마모부피가 적었다(p<0.05). 그러나, 3군, 1군, 2군 사이에서와 5군, 4군 사이에서는 각각 통계적으로 유의한 차이가 없었다. 3. 최대마모깊이는 1군에서 가장 낮았고, 4군에서 가장 깊었으며 1군<3군<5군<2군<4군의 순서로 증가 하였다. 4. 5군의 표면경도는 다른 유동성 복합레진군에 비해 통계적으로 유의하게 높았으나(p<0.05), 마모부피나 최대마모깊이와는 통계적으로 유의한 상관관계를 보이지 않았다. 5. 마모되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰한 결과, 유동성 복합레진군과 5군 사이에 마모양상이 다르게 나타나는 것을 볼 수 있었다.

  • PDF

수종의 이장재가 복합레진의 중합수축에 미치는 영향 (EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 최지원;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.606-614
    • /
    • 2006
  • 이 연구의 목적은 이장재의 종류에 따른 광중합형 복합레진 충전 후 중합수축을 비교함으로써 중합수축 감소를 보이는 좀 더 우수한 재료의 조합을 모색하고자 시행되었다. 이장재로는 유동형 레진, 컴포머, 광중합 글래스아이오노머를 사용하였고 수축응력을 측정하기 위해 스트레인 게이지를 사용하였다. 표본은 광원의 종류, 이장재의 종류에 따라 8개의 군으로 나눠졌다. 스트레인 게이지를 아크릴릭 링에 부착하고 strainmeter에 연결한 후 각 군에 따라 이장재 적용 후 광중합 하고 이장재 중합 후 750초간 수축응력을 측정하였다. 결과는 Repeated measures ANOVA와 Tukey test를 이용해 통계학적으로 분석하였다. 이상의 실험을 통해 얻은 결과는 다음과 같다. 1. 이장재를 사용하지 않은 군보다 이장재를 사용한 군의 중합수축이 적었으나 Ionosit을 사용한 군에서는 유의한 차이는 없었다(p>0.05). 2, Tetric flow 또는 Vitrebond를 이장재로 사용하는 것이 Ionosit을 사용하는 것보다 중합 수축이 적었다(p<0.05). 3. Tetric flow 이장재를 한 군은 광원에 따른 수축력의 차이가 적었고 Vitrebond와 Ionosit 이장재를 한 군은 할로겐 광원보다 LED 광원에서 수축응력이 컸으나 유의한 차이는 없었다(p>0.05).

  • PDF

차세대 레진개발을 위한 광중합형 복합레진의 마모와 화학적 분해 (ABRASION AND CHEMICAL DEGRADATION OF LIGHT-CURED COMPOSITE RESIN FOR UPDATED RESIN DEVELOPMENT)

  • 양규호;최남기;육근영
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.685-695
    • /
    • 2004
  • 복합레진은 치질과 우수한 결합력을 가지며 심미적인 이유로 치과의 대표적 수복재로 자리잡고 있다. 그러나 저작력에 따른 마모와 구강내 환경에서의 수분흡수에 따른 가수분해가 복합레진의 강도약화를 야기하고 있다. 실험에 사용된 복합레진은 현재 임상에서 많이 사용되고 있는 Point4, Tetric flow, Heliomolar flow, Filtek supreme 이다. 각 제품의 화학적 분해와 마모도를 평가하기 위해 각각 10개의 시편을 제작하여 그 중 5개는 $37^{\circ}C$의 수중하에 1Kg의 하중을 가하여 10,000 cycle동안의 마모도를 측정하였다. 나머지 5개 시편은 무게 측정을 한 후 0.1N NaOH용액, 3ml에 저장하여 $60^{\circ}C$에서 보관한 후 2주 후 제거하여 1.23% HCl로 2시간 동안 중화하고 증류수로 세척한 후 $60^{\circ}C$에서 건조하였다. 무게 손실, 분해층 깊이 및 시편내의 Si의 농도 변화. 최대 마모 깊이를 근거로 평가하여 다음과 같은 결과를 얻었다. 1. 각 제품의 무게 손실량은 Heliomolar flow, Filtek supreme, Point4, Tetric flow 순이었으며 Heliomolar flow, Filtek supreme을 제외한 다른 제품간에는 유의한 차이를 보였다(P<0.05). 2. 각 제품의 표면하 분해층 깊이는 Filtek supreme, Heliomolar flow, Tetric flow, Point4 순이었으며 Heliomolar flow, Tetric flow을 제외한 다른 제품간에는 유의 한 차이를 보였다(P<0.05). 3. 각 제품으로부터 용출된 Si은 Filtek supreme, Heliomolar flow, Point4. Tetric flow 순이었으며 Point4, Tetric flow을 제외 한 다른 제품간에는 유의한 차이를 보였다(P<0.05). 4. 최대마모깊이 측정시 Heliomolar flow, Point4, Filtek supreme, Tetric flow 순이며 0.1N NaOH 용액에 보관한 레진의 마모깊이가 물에 보관한 레진에 비해 증가한 양상을 보였다. 5. 주사전자현미경 관찰시 NaOH 용액에 보관한 후 레진 기질과 충전제 사이의 결합의 파괴를 관찰할 수 있었으며, 공촛점 레이저 현미경 관찰시 NaOH 용액에 보관한 후 수복재의 기질과 충전제 사이의 파괴양상인 분해층 깊이를 관찰할 수 있었다.

  • PDF

S-RIM을 이용한 Glass Fiber Chopped Strand Mat 강화 p-DCPD 복합재료 제작 및 수치해석을 통한 공정 시간 예측 (Manufacturing and Numerical Analysis of Glass Fiber Chopped Strand Mat Reinforced p-DCPD Composites Processed by S-RIM)

  • 유형민;엄문광;최성웅
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.629-634
    • /
    • 2019
  • Dicyclopentadiene is a low viscosity resin which forms a poly-dicyclopentadiene rapidly through ring opening metathesis polymerization (ROMP). This poly-dicyclopentadiene has outstanding properties of low-temperature, water and impact resistances. Due to these advantages, military and offshore structures try to apply the DCPD composites by using liquid composite molding process. In this study, 14%, 38% volume fraction fiber glass strand mat reinforced p-DCPD composites processed by structural reaction injection molding (S-RIM) which has resin-catalsyt mixing head and glass fiber preform in the mold. Additionally, S-RIM numerical analysis was conducted to predict the process time depending on fiber volume fraction and mold temperature. The process time is shorter when it has the lower fiber volume fraction or the higher mold temperature. At higher mold temperature, it is necessary to set the maximum mold temperature considering the resin curing time.

In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

  • Kim, Da Hye;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.39-47
    • /
    • 2017
  • Objectives: Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study investigated the adhesion of Streptococcus mutans (S. mutans) on the dental composite resins coated with three commercial surface sealants. Materials and Methods: Composite resin (Filtek Z250) discs (8 mm in diameter, 1 mm in thickness) were fabricated in a mold covered with a Mylar strip (control). In group PoGo, the surfaces were polished with PoGo. In groups PS, OG, and FP, the surfaces polished with PoGo were coated with the corresponding surface sealants (PermaSeal, PS; OptiGuard, OG; Fortify Plus, FP). The surfaces of the materials and S. mutans cells were characterized by various methods. S. mutans adhesion to the surfaces was quantitatively evaluated using flow cytometry (n = 9). Results: Group OG achieved the lowest water contact angle among all groups tested (p < 0.001). The cell surface of S. mutans tested showed hydrophobic characteristics. Group PoGo exhibited the greatest bacterial adhesion among all groups tested (p < 0.001). The sealant-coated groups showed statistically similar (groups PS and FP, p > 0.05) or significantly lower (group OG, p < 0.001) bacterial adhesion when compared with the control group. Conclusions: The application of the surface sealants significantly reduced S. mutans adhesion to the composite resin polished with the PoGo.

XAD-16-[4-(2-thiazolylazo)]orcinol 킬레이트 수지에 의한 금속이온의 분리 및 농축에 관한 연구 (Studies on the Separation and Preconcentration of Metal Ions by XAD-16-[4-(2-thiazolylazo)] orcinol Chelating Resin)

  • 이원;설경미;안혜숙;이창헌;임재희
    • 분석과학
    • /
    • 제10권4호
    • /
    • pp.282-290
    • /
    • 1997
  • XAD-16-[4-(2-thiazolylao)]orcinol (TAO)형 킬레이트 수지에 대한 U(VI), Tb(IV), Zr(IV), Cu(II), Pb(II), Ni(II), Zd(II), Cd(II) 및 Mn(II) 이온의 흡착 및 탈착 특성을 용리법으로 조사하였다. 각 금속이온의 총괄용량과 pH 변화에 따르는 혼합 금속이온의 분리능 및 금속이온의 최적 흡착 조건을 조사하기 위하여 금속이온의 흡착에 미치는 흐름속도, 완충용액의 농도에 대한 영향을 검토하였다. 킬레이트 수지에 의한 금속이온의 총괄 흡착 용량은 각각 0.35nmol U(VI)/g resin, 0.49nmol Th(VI)/g resin, 0.41nmol Cu(II)/g resin 및 0.31nmol Zr(IV)/g resin이었다. 그리고 pH 5.0에서 돌파점 용량과 총괄 용량으로부터 얻은 금속이온의 용리순서는 Th(IV)>Cu(II)>U(VI)>Zr(IV)>Pb(II)>Ni(II)>Zn(II)>Mn(II)>Cd(II)이었다. 흐름속도 0.28mL/min 및 pH 2~5범위에서 혼합 금속이온을 분리한 결과 pH가 증가함에 따라 이들 이온의 군분리가 가능하였다. 한편, $HNO_3$, HCl, $HClO_4$, $H_2SO_4$$Na_2CO_3$ 등의 탈착제에 의한 탈착특성을 조사한 결과 2M $HNO_3$는 Zr(IV)을 제외한 대부분의 금속이온들은에 대하여 높은 탈착효율을 나타냈으며, 1M $H_2SO_4$ 용액을 사용하면 Zr(IV)의 탈착 및 회수가 가능하였다. 또한 킬레이트 수지를 이용하여 미량의 U(VI) 이온이 함유된 인공 해수 시료를 용리시키고 회수한 결과 94%이상의 높은 회수율을 나타내었다. 아울러 XAD-16-TAO 킬레이트 수지는 희토류 금속의 혼합시료를 2M $HNO_3$ 용액으로 용리시키면 U(VI)의 선택적인 분리, 농축 및 회수에 유용함을 알 수 있었다.

  • PDF

C-factor와 충전법이 복합레진의 중합 수축에 의한 치질에서의 수축 응력에 미치는 영향 (EFFECT OF C-FACTOR AND LAYERING TECHNIQUE ON THE CONTRACTION FORCE OF COMPOSITE RESIN RESTORATION TO TOOTH SURFACE)

  • 이봉규;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제33권2호
    • /
    • pp.233-243
    • /
    • 2006
  • 와동 형성시 C-factor와 충전방법이 복합레진 수복물에서의 수축 응력에 미치는 영향을 평가하고자 발거된 소구치를 대상으로 C-factor가 3.6과 1.0인 와동을 각각 형성한 후 hybrid형 복합레진인 $Z-250^{TM}$(3M ESPE U.S.A.)과 flowable형 복합레진인 $Filtek\;flow^{TM}$(3M ESPE U.S.A.)를 사용하여 layering을 시행하고 광중합하면서 strain gauge법을 이용하여 치질에서의 수축 응력을 측정하였다. 시편을 절단하여 레진과 상아질 사이 계면의 접착상태를 주사전자현미경으로 관찰한 결과 다음과 같은 결과를 얻었다. 1. C-factor에 따른 수축 응력을 측정한 결과 C-factor가 3.7인 제 1군과 제 2군 그리고 제 5군이 900초 후 각각 0.11, 0.07, 0.07 MPa로 C-factor가 1.0인 제 3군과 제 4군의 0.05와 0.04 MPa에 비해 크게 나타났다(P<0.05). 1,800초 후에는 제 1군, 제 5군, 제 2군, 제 3군, 제 4순으로 크게 나타났으나 제 2군과 제 3군 그리고 제 3군과 제 4군 사이에는 유의성이 없었다. 2. 재료에 따른 수축 응력의 차이는 C-factor가 3.7인 와동의 경우 hybrid형 레진인 Filtek $Z-250^{TM}$이 flowable 레진인 $Filtek\;flow^{TM}$에 비해 수축 응력이 크게 나타났으나(P<0.05), C-factor가 1.0인 와동의 경우 재료의 차이에 따른 수축응력의 유의한 차이가 없었다. 3. Layering에 따른 수축 응력은 Filtek $Z-250^{TM}$을 layering 없이 bulk 충전한 제 1군에 비해 flowable 레진을 layering한 제 5군이 전 측정 시간대에 걸쳐 수축 응력이 유의하게 낮게 나타났다(P<0.05). 4. C-factor가 3.7인 제 1군과 제 2군 제 5군은 900초까지 수축 응력이 증가하다 이후 점차 감소하는 경향을 보였다. 5. C-factor가 1.0인 와동의 경우 충전용 레진 종류에 관계없이 레진과 와동벽 사이에 긴밀한 접착 상태를 보였으나 C-factor가 3.7인 와동의 경우 부분적으로 틈이 관찰되었다. 전반적으로 와동저에 비해 와동벽에서 틈이 더 많이 관찰되었다. 이상의 결과를 종합하여 보면 복합레진 수복시 수축응력에 따른 합병증을 예방하기 위해 C-factor를 크지 않게 와동을 설계, 형성하여야 하며 C-factor가 클 경우 flowable 레진을 이장하는 등 재료적인 면에서의 선택과 적용법이 중요할 것으로 사료된다.

  • PDF

합성수지 거푸집의 전과정 환경영향평가에 관한 연구 (A Study on Life-Cycle Environmental Impact of Synthetic Resin Formwork)

  • 남경용;양근혁;이영도
    • 한국건축시공학회지
    • /
    • 제20권3호
    • /
    • pp.245-252
    • /
    • 2020
  • 합성수지 거푸집은 내부식성이 우수한 경량의 고밀도 폴리에틸렌(HDPE)를 재료로 사용한다. 합성수지 거푸집의 전과정 평가를 위하여 ISO FDIS 13352에서 요구하는 시스템 경계를 만족하도록 공정 흐름도를 고려하였다. 이에 따라 고려된 시스템 경계는 Cradle-to- Product shipmen이다. 고려된 시스템 경계에서 투입 에너지원, 사용재료, 운송수단, 제작공정 등으로부터 산정한 전과정 목록(LCI) 데이터베이스를 분석하였다. 합성수지 거푸집의 LCI 데이터 분석으로 부터 환경부의 환경영향평가지수 방법론에 기반하여 분류화, 정규화, 특성화 및 가중치 과정을 거쳐 환경영향평가를 수행하고, 그 결과는 유로폼의 환경영향 평가값과 비교하였다. 실험결과, 전용횟수를 고려한 CO2 배출량은 유로폼 대비 2배 이상의 전용성을 갖는 합성수지 거푸집이 약 32 % 가량 낮았다. 이는 합성수지 거푸집 사용은 유로폼 대비 자재 생산을 1/2로 줄일 수 있으며, CO2 배출량 저감으로 이어질 수 있다.