• 제목/요약/키워드: Resin crown

검색결과 315건 처리시간 0.023초

Indirect short resin post Crown을 이용한 유전치부 심미수복 (ESTHETHIC RESTORATION OF PRIMARY ANTERIOR TEETH BY INDIRECT SHORT RESIN POST CROWN : CASE REPORT)

  • 김효석;한국재;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.627-634
    • /
    • 1998
  • Children who have severely destructive anterior primary dentition, as in nursing-bottle caries, in trauma, in rampant caries and in developmental defects, present the dentist with one of the most perplexing situations in dentistry. Especially, children with managed behavor difficultly is very severly situations. This paper reported a new technique for the utilization of resin post and strip crown to indirect methods on severely destructive primary anterior teeth. We name it "indirect short resin post crown" in this paper. Indirect technique be considered to be a simple, a retentive, intensive, color-stable and esthetic restoration.

  • PDF

치과 치료학에서 적용되는 접합기술 연구 ; 스테인리스강 크라운에 접합된 직접용 콤포짓트 레진과 간접용 콤포짓트 레진의 전단결합강도 비교 (Comparison Study for the Shear Strength of the Bondings between Stainless Steel Crown/Direct Type Composite Resin and Stainless Steel Crown/Indirect Type Composite Resin)

  • 김광수;백광우
    • Journal of Welding and Joining
    • /
    • 제29권4호
    • /
    • pp.93-99
    • /
    • 2011
  • This study was performed to compare the shear strength of the bondings between stainless steel crown/direct type composite resin and stainless steel crown/indirect type composite resin. Four groups of bonding conditions were prepared. Two groups of bonding conditions were made by the indirect type composite resin system and the other two groups were made by the direct type composite resin system. The shear strength tests were carried out using universal testing machine, Model 4465 of Instron Co.. It was indicated that the bond strength values of the indirect type composite resins were higher than those of the direct type composite resins. TE-SE group was superior to the TE-ONE in indirect type resin system. These results were thought to be the high degree of the polymerization accompanied with temperature and pressure of the resin of indirect type resin. It was also found that indirect composite resin contains less amount of porosity in resin.

Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향 (THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT)

  • 하점임;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • 대한소아치과학회지
    • /
    • 제51권1호
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.

어린이 음료수가 레진관과 지르코니아 기성관의 색조에 미치는 영향 (Effects of Children's Drinks on the Color Stability of Strip and Zirconia crown)

  • 정일용;이석순;이한이;이대우;양연미;김재곤
    • 대한소아치과학회지
    • /
    • 제44권3호
    • /
    • pp.306-316
    • /
    • 2017
  • 이 연구는 유전치와 그 심미 수복에 사용되는 전장관의 어린이 음료수에 대한 색조 안정성을 평가하였다. 우식 및 변색 없이 자연 탈락된 20개의 상악 우측 유중절치와 상악 우측 유중절치 모양의 resin strip crown 40개 및 Nu-smile zirconia crown 20개를 대상으로 하였다. 복합 레진의 연마 여부에 따른 색조 안정성을 비교하기 위해 40개의 resin strip crown 중 20개는 $Sof-lex^{TM}$ Contouring and Polishing Discs를 이용하여 연마하였다. 이 후 각각의 시편을 5개씩 나누어 증류수, 콜라, 포도주스, 젤리주스에 6일간 담갔다. 그 결과 네 음료수 군에서 모든 시편의 색조 변화가 있었으며, 연마한 resin strip crown은 연마하지 않은 군에 비해 색조 변화가 컸고 콜라, 포도주스, 젤리주스에서 통계적으로 유의하였다(p < 0.05). Zirconia crown의 경우 포도주스와 콜라에서의 색조 변화 값은 통계적으로 유의하지 않았으나 젤리주스와 나머지 두 음료수 사이에서는 유의하였다(p < 0.05). 따라서 소아 유전치 수복에 사용하는 수복재료들도 어린이 음료수에 노출될 경우 색조 변화가 있을 수 있으므로 어린이 음료수에 대한 식이 조절이 필요하다.

Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석 (The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant)

  • 정관호;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

강화형 strip crown의 사용 (GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH)

  • 김대업
    • 대한소아치과학회지
    • /
    • 제32권1호
    • /
    • pp.132-135
    • /
    • 2005
  • 본 연구의 목적은 유전치 심미수복의 새로운 방법으로 glass fiber를 이용한 강화형 strip crown의 사용을 제시하고자 하는 것이다. Strip crown의 제작을 위하여 celluloid crown form(3M, USA)과 복합레진은 Z100(P shade, 3M, USA)을, 유동성 복합레진은 Aeliteflo(Bisco Inc., USA)를 사용하였다. 상아질 결합제는 Clearfil SE Bond(Kuraray Medical Inc., Japan)를 사용하였고 강화를 위하여 그물형 glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA)를 사용하였다. 적절한 크기의 celluloid crown form을 성형하여 삭제된 치아에 시적한 후 레진 접착제와 유동성 복합레진으로 처리한 그물형 glass fiber를 설측 내면에 삽입하고 광중합하였다. 잔여 공간에 복합레진을 채우고 치아에 끼운 다음 광중합하였다. 복합레진의 심미성은 유지하면서 glass fiber로부터 기계적 장점을 얻을 수 있을 것으로 사료된다. 새로운 강화형 strip crown의 물성에 대한 후속연구가 필요하다.

  • PDF

1-Aza-18-Crown-6-Styrene-DVB 수지에 의한 U(VI), Mg(II), Ho(III) 이온들의 흡착 (Adsorption of U(VI), Mg(II), Ho(III) Ions on the 1-Aza-18-Crown-6-Styrene-DVB Resin)

  • 김해진;김선화
    • 환경위생공학
    • /
    • 제22권1호
    • /
    • pp.49-56
    • /
    • 2007
  • The effects of pH, time, dielectric constant of solvent and crosslink on adsorption of metal ions by 1-aza-18-crown-6-styrene-DVB(divinylbenzene) resin(resin) adsorbent were investigated. The metal ions were showed fast adsorption on the resins in over pH 3. The equilibrium time for adsorption of metallic ions was about two hours and the adsorption selectivity determined in methanol was in increasing order $UO_2^{2+}>Mg^{2+}>Ho^{3+}$ ions. The adsorption was in the order of 1%, 2% and 4% crosslink resin and adsorption of resin decreased in proportion to the order of dielectric constant of solvents.

Adsorption of Rare Earth Metal Ion on N-Phenylaza-15-Crown-5 Synthetic Resin with Styrene Hazardous Material

  • Kim, Se-Bong;Kim, Joon-Tae
    • 통합자연과학논문집
    • /
    • 제7권2호
    • /
    • pp.130-137
    • /
    • 2014
  • Resins were synthesized by mixing N-phenylaza-15-crown-5 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous materials) divinylbenzene (DVB) copolymer with crosslink of 1%, 2%, 6%, and 12% by substitution reaction. The synthesis of these resins was confirmed by content of chlorine, element analysis, thermo gravimetric analysis (TGA), surface area, and IR-spectroscopy. The effects of pH, equilibrium arrival time, dielectric constant of solvent and crosslink on adsorption of metal ions by the synthetic resin adsorbent were investigated. The metal ions were showed fast adsorption on the resins above pH 4. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order uranium (VI) > zinc (II) > europium (III) ions. The uranium ion adsorbed in the order of 1%, 2%, 6%, and 12% crosslink resin and adsorption of resin decreased in proportion to the order of dielectric constant of solvents.

Adsorption of Uranium (VI) Ion on 1-Aza-12-Crown-4 Synthetic Resin with Styrene Hazardous Material

  • Kim, Joon-Tae
    • 통합자연과학논문집
    • /
    • 제6권2호
    • /
    • pp.104-110
    • /
    • 2013
  • 1-Aza-12-crown-4 macrocyclic ligand was combined with styrene (2th petroleum in 4th class hazardous materials) divinylbenzene copolymer having 1%, 2%, 3%, and 6% crosslinks by a substitution reaction, in order to synthesize resin. These synthetic resins were confirmed by chlorine content, elementary analysis and IR-spectrum. As the results of the effects of pH, equilibrium arrival time, crosslink of synthetic resin, and dielectric constant of a solvent on uranium ion adsorption for resin adsorbent, the uranium ion showed high adsorption at pH 3 or over and adsorption equilibrium of uranium ion was about 2 hours. In addition, adsorption selectivity for the resin in methanol solvent was the order of uranium ($UO_2{^{2+}}$) > iron ($Fe^{3+}$) > lutetium ($Lu^{3+}$) ions, adsorbability of the uranium ion was in the crosslinks order of 1%, 2%, 3%, and 6% was increased with the lower dielectric constant.