• Title/Summary/Keyword: Resin crown

Search Result 315, Processing Time 0.024 seconds

ESTHETHIC RESTORATION OF PRIMARY ANTERIOR TEETH BY INDIRECT SHORT RESIN POST CROWN : CASE REPORT (Indirect short resin post Crown을 이용한 유전치부 심미수복)

  • Kim, Hyo-Suck;Han, Kok-Jae;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.627-634
    • /
    • 1998
  • Children who have severely destructive anterior primary dentition, as in nursing-bottle caries, in trauma, in rampant caries and in developmental defects, present the dentist with one of the most perplexing situations in dentistry. Especially, children with managed behavor difficultly is very severly situations. This paper reported a new technique for the utilization of resin post and strip crown to indirect methods on severely destructive primary anterior teeth. We name it "indirect short resin post crown" in this paper. Indirect technique be considered to be a simple, a retentive, intensive, color-stable and esthetic restoration.

  • PDF

Comparison Study for the Shear Strength of the Bondings between Stainless Steel Crown/Direct Type Composite Resin and Stainless Steel Crown/Indirect Type Composite Resin (치과 치료학에서 적용되는 접합기술 연구 ; 스테인리스강 크라운에 접합된 직접용 콤포짓트 레진과 간접용 콤포짓트 레진의 전단결합강도 비교)

  • Kim, Gwang-Soo;Baek, Kwang-Woo
    • Journal of Welding and Joining
    • /
    • v.29 no.4
    • /
    • pp.93-99
    • /
    • 2011
  • This study was performed to compare the shear strength of the bondings between stainless steel crown/direct type composite resin and stainless steel crown/indirect type composite resin. Four groups of bonding conditions were prepared. Two groups of bonding conditions were made by the indirect type composite resin system and the other two groups were made by the direct type composite resin system. The shear strength tests were carried out using universal testing machine, Model 4465 of Instron Co.. It was indicated that the bond strength values of the indirect type composite resins were higher than those of the direct type composite resins. TE-SE group was superior to the TE-ONE in indirect type resin system. These results were thought to be the high degree of the polymerization accompanied with temperature and pressure of the resin of indirect type resin. It was also found that indirect composite resin contains less amount of porosity in resin.

THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT (Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향)

  • Ha Jum-Im;Cho Hye-Won;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.

Effects of Children's Drinks on the Color Stability of Strip and Zirconia crown (어린이 음료수가 레진관과 지르코니아 기성관의 색조에 미치는 영향)

  • Jeong, Ilyong;Yi, Seoksoon;Lee, Haney;Lee, Daewoo;Yang, Yeonmi;Kim, Jaegon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.306-316
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of exposure to various children's drinks on the color stability of anterior primary teeth and different esthetic restorative materials clinically used in pediatric dentistry. Exfoliated maxillary primary central incisors that had been unaffected by caries were chosen as control group. Maxillary primary central incisor-shaped specimens made of strip crown and Nu-smile zirconia crowns were chosen as test groups. Polished strip resin crowns were additionally prepared to compare with unpolished strip resin crown. Each specimen and teeth were divided into 4 groups in which the test samples (n=5 each) were immersed in 4 different drinks (distilled water, cola, grape juice, jelly juice) for 6 days. In all 4 drink groups, all specimens generally showed increasing ${\Delta}E^*$ value (color difference) with time. Polished resin strip crown had higher ${\Delta}E^*$ value than the unpolished in cola, grape juice and jelly juice groups. ${\Delta}E^*$ value of zirconia crown in cola, grape juice and jelly juice groups were significantly different (p < 0.05). In conclusion, dietary control of children's drinks is required for preventing discoloration of restorative materials.

The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant (Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석)

  • Jeong, Gwan-Ho;Bae, Tae Seong;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH (강화형 strip crown의 사용)

  • Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.132-135
    • /
    • 2005
  • The purpose of this study was to propose the modified strip crown technique for esthetic restoration of primary anterior teeth using glass fibers. Celluloid crown form(3M, USA), Z100(P shade, 3M, USA). Aeliteflo(Bisco Inc., USA), and Clearfil SE Bond(Kuraray Medical Inc., Japan) were used for this technique. Mesh type of glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA) was used for reinforcing material. After trimming the celluloid crown form, resin adhesive and flowable resin were applied on the pre-shaped glass fiber mesh. That mesh was placed on the lingual surface of inside of celluloid crown form and followed by light activation. Composite resin was filled into the celluloid crown form and put it on a prepared tooth and then light activated and finished the margin. The new modified strip crown technique can provide esthetics and increased durability for restoration of primary anterior teeth.

  • PDF

Adsorption of U(VI), Mg(II), Ho(III) Ions on the 1-Aza-18-Crown-6-Styrene-DVB Resin (1-Aza-18-Crown-6-Styrene-DVB 수지에 의한 U(VI), Mg(II), Ho(III) 이온들의 흡착)

  • Kim, Hae-Jin;Kim, Sun-Hwa
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.1 s.63
    • /
    • pp.49-56
    • /
    • 2007
  • The effects of pH, time, dielectric constant of solvent and crosslink on adsorption of metal ions by 1-aza-18-crown-6-styrene-DVB(divinylbenzene) resin(resin) adsorbent were investigated. The metal ions were showed fast adsorption on the resins in over pH 3. The equilibrium time for adsorption of metallic ions was about two hours and the adsorption selectivity determined in methanol was in increasing order $UO_2^{2+}>Mg^{2+}>Ho^{3+}$ ions. The adsorption was in the order of 1%, 2% and 4% crosslink resin and adsorption of resin decreased in proportion to the order of dielectric constant of solvents.

Adsorption of Rare Earth Metal Ion on N-Phenylaza-15-Crown-5 Synthetic Resin with Styrene Hazardous Material

  • Kim, Se-Bong;Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.7 no.2
    • /
    • pp.130-137
    • /
    • 2014
  • Resins were synthesized by mixing N-phenylaza-15-crown-5 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous materials) divinylbenzene (DVB) copolymer with crosslink of 1%, 2%, 6%, and 12% by substitution reaction. The synthesis of these resins was confirmed by content of chlorine, element analysis, thermo gravimetric analysis (TGA), surface area, and IR-spectroscopy. The effects of pH, equilibrium arrival time, dielectric constant of solvent and crosslink on adsorption of metal ions by the synthetic resin adsorbent were investigated. The metal ions were showed fast adsorption on the resins above pH 4. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order uranium (VI) > zinc (II) > europium (III) ions. The uranium ion adsorbed in the order of 1%, 2%, 6%, and 12% crosslink resin and adsorption of resin decreased in proportion to the order of dielectric constant of solvents.

Adsorption of Uranium (VI) Ion on 1-Aza-12-Crown-4 Synthetic Resin with Styrene Hazardous Material

  • Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.6 no.2
    • /
    • pp.104-110
    • /
    • 2013
  • 1-Aza-12-crown-4 macrocyclic ligand was combined with styrene (2th petroleum in 4th class hazardous materials) divinylbenzene copolymer having 1%, 2%, 3%, and 6% crosslinks by a substitution reaction, in order to synthesize resin. These synthetic resins were confirmed by chlorine content, elementary analysis and IR-spectrum. As the results of the effects of pH, equilibrium arrival time, crosslink of synthetic resin, and dielectric constant of a solvent on uranium ion adsorption for resin adsorbent, the uranium ion showed high adsorption at pH 3 or over and adsorption equilibrium of uranium ion was about 2 hours. In addition, adsorption selectivity for the resin in methanol solvent was the order of uranium ($UO_2{^{2+}}$) > iron ($Fe^{3+}$) > lutetium ($Lu^{3+}$) ions, adsorbability of the uranium ion was in the crosslinks order of 1%, 2%, 3%, and 6% was increased with the lower dielectric constant.