• 제목/요약/키워드: Resin composite

검색결과 1,963건 처리시간 0.025초

Bonding of conventional provisional resin to 3D printed resin: the role of surface treatments and type of repair resins

  • Lim, Na-Kyung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.322-328
    • /
    • 2020
  • PURPOSE. This study evaluated the shear bond strength between 3D printed provisional resin and conventional provisional resin depending on type of conventional provisional resin and different surface treatments of 3D printed resin. MATERIALS AND METHODS. Ninety-six disc-shaped specimens (Ø14 mm × 20 mm thickness) were printed with resin for 3D printing (Nextdent C&B, Vertex-Dental B. V., Soesterberg, Netherlands). After post-processing, the specimens were randomly divided into 8 groups (n=12) according to two types of conventional repair resin (methylmethacrylate and bis-acryl composite) and four different surface treatments: no additional treatment, air abrasion, soaking in methylmethacrylate (MMA) monomer, and soaking in MMA monomer after air abrasion. After surface treatment, each repair resin was bonded in cylindrical shape using a silicone mold. Specimens were stored in 37℃ distilled water for 24 hours. The shear bond strength was measured using a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were analyzed by scanning electron microscope. Statistical analysis was done using one-way ANOVA test and Kruskal-Wallis test (α=.05). RESULTS. The group repaired with bis-acryl composite without additional surface treatment showed the highest mean shear bond strength. It was significantly higher than all four groups repaired with methylmethacrylate (P<.05). Additional surface treatments, neither mechanical nor chemical, increased the shear bond strength within methylmethacrylate groups and bis-acryl composite groups (P>.05). Failure mode analysis showed that cohesive failure was most frequent in both methylmethacrylate and bis-acryl composite groups. CONCLUSION. Our results suggest that when repairing 3D printed provisional restoration with conventional provisional resin, repair with bis-acryl composite without additional surface treatment is recommended.

공초점레이저주사현미경을 이용한 심미수복재와 상아질의 접착계면에 관한 연구 (A CONFOCAL LASER SCANNING MICROSCOPIC STUDY ON THE INTERFACE BETWEEN TOOTH COLORED RESTORATIVE MATERIALS AND DENTIN)

  • 박병철;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.313-320
    • /
    • 2000
  • The purpose of this study was to evaluate on the interfacial morphology between dentin and restorative materials. In this in vitro study, the cavity wall restorated with 3 different kinds of tooth colored restorative materials [resin-modified Glass Ionomer cement (Fuji II LC), composite resin (Z-100), compomer (Dyract)]. The thirty extracted human molar teeth without caries and/or restorations are used. The experimental teeth were randomly divided into three groups of ten teeth each. In each group, Wedge shaped cavities (width: 3mm, length: 2mm, depth: 1.5mm) were prepared at the cementoenamel junction on buccal and lingual surfaces. The adhesive of composite resin were mixed with rhodamine B. Primer of composite resin, Prime & Bond 2.1 of Dyract and liquid of Fuji II LC were mixed with fluorescein. In group 1, the cavity wall was treatment with dentin conditioner, and then restorated with Fuji II LC. In group 2, the cavity wall was treatment with Prime & Bond 2.1 and then restorated with Dyract. In group 3, the cavity wall was etching with 10% maleic acid, applied with primer and bonding agent and then restorated with Z-100. The interface between dentin and restorative materials was observed by fluoresence imaging with a confocal laser scanning microscope. The results were as follows : 1. In Glass ionomer group, adaptation of resin modified Glass-ionomer restoration against cavity wall is tight, but the crack formed inside of restoration were observed. 2. In Dyract group, the penetration of resin tag is shorter and the width of hybrid layer is narrower than composite resin group. 3. In Z-100 group, primer penetrated deeply through dentinal tubule. Also bonding agent was penetrated along the primer, but the penetration length is shorter than primer part, and in 3-D image, the resin tag is conical shape and lateral branch is observed.

  • PDF

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권2호
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

복합레진 충전시 Glass Inserts의 적용이 변연누출에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF GLASS INSERTS ON MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 김용철;김용기
    • 대한소아치과학회지
    • /
    • 제24권2호
    • /
    • pp.383-404
    • /
    • 1997
  • In this study, we tried to compare the effect of glass inserts on marginal leakage of composite resin restoration by comparing with that of several filling methods. The results obtained from this experiment were as follows ; 1. The degree of microleakage measured in glass inserts group was generally lower than that of the other groups. Statistical analysis showed significant intergroup difference between glass inserts and one complete unit, pre-polymerized composite resin ball(P<.05), but no significant difference between groups of glass inserts and increments(P>.05). 2. Scanning electron microscopic observation showed relatively large gap around resin-tooth interface in specimens restored the method of using the one complete unit and pre-polymerized composite resin ball whereas a denser and tighter was observed in increments and glass inserts group. Generally the gingival margin was shown to have better bonds than the occlusal margin in specimen of all groups. 3. In the present experiment, methods using the techniques of glass inserts and increments were evaluated to be superior to those of one complete unit, pre-polymerized composite resin ball in the aspect of microleakage. However, the result of this study could not determine the superiority of the use of glass inserts over incremental method. Besides the physical properties observed in this study, the practical aspect of clinical convenience should be considered in determining the selection of material.

  • PDF

세로머, 세라믹 및 복합레진의 기계적 성질의 비교에 관한 연구 (A COMPARATIVE STUDY ON THE MECHANICAL PROPERTIES OF CEROMER, CERAMIC AND INDIRECT COMPOSITE RESIN)

  • 백정화;박일윤;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.233-239
    • /
    • 1999
  • Recently, a second generation composite resin system(ceromer) was introduced with significantly improved mechanical properties. The purpose of this study was to compare a ceromer with the other restorative materials and to assess its clinical usefulness. In this study, we used four restorative materials : amalgam (BESTALOY$^{(R)}$), indirect composite resin (Clearfil CR Inlay$^{(R)}$), ceromer (Targis$^{(R)}$) and ceramic (Vintage$^{(R)}$). And then we devided into four groups. The materials of each group were as follows : Amalgam group : BESTALOY$^{(R)}$ (Dong Myung Dental Industrial Co.) Composite Resin group : Clearfil CR Inlay$^{(R)}$ (Kuraray) Ceromer group : Targis$^{(R)}$ Dentin (Ivoclar-Vivadent) Ceramic group : Vintage$^{(R)}$ (Shofu Inc.) According to the above classification, we made samples through the polymerization of BESTALOY$^{(R)}$, Clearfil CR Inlay$^{(R)}$ and Targis$^{(R)}$ with separable cylindrical metal mold and firing of Vintage$^{(R)}$ in a investment mold. And then, we measured and compared the value of compressive strength, diametral tensile strength and Vicker's microhardness of each sample. The results were as follows : 1. Amalgam showed the highest value of compressive strength (390.37${\pm}$42.22MPa) and the value of ceromer was somewhere between ceramic and indirect composite resin. There were significant differences among the experimental groups(p<0.001). 2. Indirect composite resin showed the highest value of diametral tensile strength (74.21${\pm}$15.33MPa) and there was no significant difference with ceromer. Ceromer was higher diametral tensile strength than amalgam and ceramic (p<0.001). 3. Ceramic showed the highest value of microhardness (538.44${\pm}$37.38Hv) and the value of ceromer was somewhere between ceramic and indirect composite resin. There were significant differences among the experimental groups (p<0.001).

  • PDF

Glass Fiber Post와 Composite Resin Core의 전단결합강도 (A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST)

  • 김태형;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

BCB Resin-BNT 복합 기판 소재의 제조 및 특성 평가 (Preparation and Characterization of BCB Resin-BNT Composite Substrate Materials)

  • 김운용;전명표;조정호;김병익;이용현;명성재;한익현;신동욱
    • 한국세라믹학회지
    • /
    • 제44권5호
    • /
    • pp.179-183
    • /
    • 2007
  • BCB $Resin-BaNd_2Ti_4O_{12}$(BNT) composites with BNT contents were prepared by tape casting method and epoxy resin-BNT composites were prepared by using heating press. Their dielectric properties and microstructures were investigated. The dielectric properties such as dielectric constant and dielectric loss at 1 MHz for epoxy resin-BNT composites and BCB resin-BNT composites are improved with an increase of BNT volume fraction. The dielectric constant of the Epoxy-BNT composite increased from 5.9 to 7.8 as the volume fraction of BNT increased from 15 to 25. The dielectric constant of the BCB-BNT composite increased from 9.1 to 15.5 as the volume fraction of BNT increased from 30 to 50. The dielectric behavior of BCB-BNT system can be explained by Lichtenecker's equation. The dielectric constant of epoxy resin-BNT composite is smaller than that of BCB resin-BNT composite. These results are considered to be related with the dispersion of BNT filler in polymer matrix from the result of SEM photograph.

2급 와동 복합레진 인레이 충전 후 변연누출에 관한 연구 (A STUDY ON THE MARGINAL LEAKAGE OF CLASS II COMPOSITE RESIN INLAY)

  • 강현숙;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.191-205
    • /
    • 1992
  • The purpose of this study was to evaluate the microleakage of class II composite resin inlays and compare them with the conventional light-cured resin filling restorations. Class II cavities were prepared in 60 extracted human molars with which cervical margins were located below 1.0mm at the cemento-enamel junction using No. 701 tapered fissure carbide bur. All of the prepared cavities were restored as follows and divided into 6 groups. Group I and 2 were restored using direct filling technique and group 3,4,5 and 6 were restored using direct inlay technique that was cemented with dual-cured resin cements. group I: Cavities were restored with light-curing composite resin, Brilliant Lux. group 2. Cavities were restored with light-curing composite resin, Clearfil PhotoPosterior. group 3: Cavities were restored with Clearfil CR Inlay and heat treated at $125^{\circ}C$ for 7 minutes. group 4: Cavities were restored with same material as group 3 and heat treated at $100^{\circ}C$ for 15 minutes. group 5: Cavities were restored with Brilliant (Indirect esthetic system) and heat treated at $125^{\circ}C$ for 7 minutes. group 6: Cavities were restored with same material as group 5 and heat treated at $100^{\circ}C$ for 15 minutes. All specimens were polished with same method and thermocycled between $6^{\circ}C$ and $60^{\circ}C$, then immersed in a bath of 2.0% aqueous solution of basic fuchsin dye for 24 hours. Dyed specimens were sectioned longitudinally and dye penetration degree was read on a scale of 0 to 4 by Tani and Buonocore's method 45). The results were as follows: 1. Microleakage was observed rather at the cervical margins than at the occlusal margins in all groups. 2. Composite resin inlay groups showed significantly less leakage than direct filling groups at the cervical margins (p < 0.001). 3. In composite resin inlay groups, there was no significant difference in microleakage between specimens by heat treating temperature and time (p > 0.05). 4. There was no significant difference in leakage between each groups at the occlusal margins (p > 0.05).

  • PDF

Degree of conversion of resin composite cured by light through a translucent fiber posts

  • Urapepon, Somchai
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.194-199
    • /
    • 2014
  • PURPOSE. This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS. The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cured composite at bottom surface were examined using Fourier transform infrared attenuated total reflection spectrometer (FTIR/ATR) at 0.1, 0.5 and 1.0 mm apart from the post surface. RESULTS. The degree of conversion of the 0.1 mm, 0.5 mm, 1.0 mm apart from the post surface was highest at the 2 mm level and continuously decreased when the distance from the light source was increased and drastically decreased when the depth from the top of the post was greater than 4-6 mm. For each level, the highest degree of conversion was at 0.1 mm from the post surface and decreased continuously when the distance apart from the post surface was increased. CONCLUSION. The quantity of light transmission depends on the type of post and the light transmission capability of the post, especially after 4-6 mm depth and the area further apart from the post surface, are insufficient for clinical light activation of resin composite.

구치부 수복용 복합레진의 파괴특성에 관한 Acoustic Emission 연구 (ACOUSTIC EMISSION ANALYSIS FOR FRACTURE CHARACTERISTICS OF DENTAL POSTERIOR COMPOSITES)

  • 박진훈;김교한
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.153-165
    • /
    • 1992
  • Dental composite resin is a kind of the particle - reinforced composite material, and is widely used in recent dental restoration of anterior and posterior tooth region. The purpose of this study was to investigate the fracture behaviour according to volume fractions and external findings of the filler particles for better interpretation of the fracture characteristics of posterior dental composite resins by analytic method of fracture mechanics. The plane strain fracture toughness($K_{IC}$) and Acoustic Emission were determined with three - point bending test using the single edge notch specimen according to the ASTM - E399, and its analyzed data was compared with filler volume fractions derived from the standard ashing test and scanning electron fractographs of each specimen including the unfilled experimental resin as a control. The results were that the value of fracture toughness of the composite resin material was in the range from 0.85 MPa$\sqrt{m}$ to 1.60 MPa$\sqrt{m}$ and was higher than the value of the unfilled experimental resin, and the fracture behaviours dervied from Acoustic Emission analysis show prominent differences according to the volume fraction and the size of filler particles used in each composite resin. The degree of resistance against crack propagation seems to be increase and the fractographs demonstrate the high degree of surface roughness and irregularity according with the increase of fracture toughness value.

  • PDF