• Title/Summary/Keyword: Resin base

Search Result 442, Processing Time 0.022 seconds

Relationship between Weather-Resistance and Mixing Ratio of Mill-Base and Let-Down Silicone/Acrylic Resins (안료분산용 및 희석용 실리콘/아크릴수지의 배합비와 내후성과의 상관관계)

  • Jo Hye-Jin;Shim Il-Woo;Hahm Hyun-Sik;Park Hong-Soo
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.350-356
    • /
    • 2006
  • In order to investigate the effect of the composition of weather-resistant coatings on physical properties, three different weather-resistant coatings were prepared by varying the ratio of a mill-base silicone/acrylic resin and let-down silicone/acrylic resin in weight ratios of 2 : 8, 3 : 7, and 4 : 6. The physical properties and weather-resistance of the prepared coatings were tested. It was found that the thermal stability, salt spray exposure, and weather-resistance were improved with increasing the amount of silicone. The optimum mixing ratio of mill-base silicone/acrylic resin to the let-down silicone/acrylic resin was 2 : 8. The coating containing silicone component of 30 wt% was found to be suitable as high weather-resistant coatings.

Fabrication of Waterproof and Moisture-permeable Polyurethane Nanofiber Multi-Membrane (투습방수성 Polyurethane 나노섬유 Multi-Membrane의 제조)

  • Yang, Jeong-Han;Yoon, Nam-Sik;Kim, In-Kyo;Yeum, Jeong-Hyun
    • Textile Coloration and Finishing
    • /
    • v.23 no.2
    • /
    • pp.107-117
    • /
    • 2011
  • Polyurethane (PU) was synthesized by one-shot process and the PU nanofiber was prepared by electrospinning. In this study, electrospun PU multi-membranes were prepared with various coating thickness ratio of base resin to top resin, where the base resin contains melamine curing agent and acid catalyst and the top resin contains water-repellent agent of fluoro-carbon compounds. The PU nanofiber multi-membranes were analyzed by field-emission scanning electron microscopy, differential scanning calorimeter, breathability, tensile strenth, air permeability and water resistance. The results showed that the PU multi-membrane provided excellent waterproof and moisture permeability.

EFFECT OF SECONDARY HEAT TREATMENT ON DIMENSIONAL CHANGES OF ACRYLIC RESIN PARTIAL DENTURE BASE (2차 가열에 의한 국소의치상의 변형에 관한 실험적 연구)

  • Jang, Byung-Gun;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.193-211
    • /
    • 1989
  • The purpose of this study was to investigate the effect of secondary heat treatment on dimensional changes of acrylic resin partial denture base. For this study, 6 specimens were made: 2 groups of 2 specimens, each was treated with $125^{\circ}C$ dry heat and glycerine heat for 3 minutes, and the others were prepared for control group. The change of the internal diameter of specimens were measured after 3 hrs, 1 day, 1 week, 2 weeks, 4 weeks by three-dimensional space analyzer. The results were as follows : 1. All of the acrylic resin denture bases showed tissue ward thermal contraction. 2. Thermal contraction of the mesial area reinforced with metal framework was lesser than that of the distal area without metal framework. 3. Thermal contraction of the lingual flange reinforced with metal framework occured more slowly than that of the buccal flange without the metal framework. 4. The thermal contraction of dry heat treated acrylic resin base, compared to glycerine heat group, was moderately greater and occurred acutely.

  • PDF

Synthesis and Characterization of Schiff Base Metal Complexes and Reactivity Studies with Malemide Epoxy Resin

  • Lakshmi, B.;Shivananda, K.N.;Prakash, Gouda Avaji;Isloor, Arun M.;Mahendra, K.N.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.473-482
    • /
    • 2012
  • A novel malemide epoxy containing Co(II), Ni(II) and Cu(II) ions have been synthesized by curing malemide epoxy resin (MIEB-13) and Co(II), Ni(II) and Cu(II) complexes of macrocyclic bis-hydrazone Schiff base. The Schiff base was synthesized by reacting 1,4-dicarbnyl phenyl dihydrazide with 2,6-diformyl-4-methyl phenol. The Schiff base and its Co(II), Ni(II) and Cu(II) complexes have been characterized by elemental analyses, spectral (IR, $^1H$ NMR, UV-vis., FAB mass, ESR), thermal and magnetic data. The curing reaction of maleimide epoxy compound with metal complexes was studied as curing agents. The stability of cured samples was studied by thermo-gravimetric analyses and which have excellent chemical (acid/alkali/solvent) and water absorption resistance. Further, the scanning electron microscopy (SEM) and definitional scanning colorimetric (DSC) techniques were confirmed the phase homogeneity of the cured systems.

Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step (연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가)

  • Hwang, Seong-Sig;Im, Yong-Woon;Kim, Si-Chul;Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE MATERIAL OF RESIN BASE IN INDIRECT BRACKET BONDING (브라켓 간접부착시 레진 베이스의 재료에 따른 전단결합강도와 파절양상 비교)

  • Jeon, Man-Bae;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.277-284
    • /
    • 1998
  • The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows : 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in ARI score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.

  • PDF

Adhesion of biofilm, surface characteristics, and mechanical properties of antimicrobial denture base resin

  • Ana Beatriz Vilela Teixeira;Mariana Lima da Costa Valente;Joao Pedro Nunes Sessa;Bruna Gubitoso;Marco Antonio Schiavon;Andrea Candido dos Reis
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.80-92
    • /
    • 2023
  • PURPOSE. This study incorporated the nanomaterial, nanostructured silver vanadate decorated with silver nanoparticles (AgVO3), into heat-cured resin (HT) at concentrations of 2.5%, 5%, and 10% and compared the adhesion of multispecies biofilms, surface characteristics, and mechanical properties with conventional heat-cured (HT 0%) and printed resins. MATERIALS AND METHODS. AgVO3 was incorporated in mass into HT powder. A denture base resin was used to obtain printed samples. Adhesion of a multispecies biofilm of Candida albicans, Candida glabrata, and Streptococcus mutans was evaluated by colony-forming units per milliliter (CFU/mL) and metabolic activity. Wettability, roughness, and scanning electron microscopy (SEM) were used to assess the physical characteristics of the surface. The mechanical properties of flexural strength and elastic modulus were tested. RESULTS. HT 10%-AgVO3 showed efficacy against S. mutans; however, it favored C. albicans CFU/mL (P < .05). The printed resin showed a higher metabolically active biofilm than HT 0% (P < .05). There was no difference in wettability or roughness between groups (P > .05). Irregularities on the printed resin surface and pores in HT 5%-AgVO3 were observed by SEM. HT 0% showed the highest flexural strength, and the resins incorporated with AgVO3 had the highest elastic modulus (P < .05). CONCLUSION. The incorporation of 10% AgVO3 into heat-cured resin provided antimicrobial activity against S. mutans in a multispecies biofilm did not affect the roughness or wettability but reduced flexural strength and increased elastic modulus. Printed resin showed higher irregularity, an active biofilm, and lower flexural strength and elastic modulus than heat-cured resin.

A CLINICAL STUDY ON THE RETENTION OF MAXILLARY COMPLETE DENTURE WITH DIFFERENT DENTURE BASE MATERIALS (의치상의 종류에 따른 상악 의치상의 유지력에 관한 임상적 연구)

  • Lee Jong-Hyuk;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.58-70
    • /
    • 2001
  • For the successful treatment of complete denture, obtaining a good retention is essential. There are lots of factors affecting denture retention. Denture material, one of those factors affecting denture retention, was the subject of this study, and internal surface treatment also considered for the method of enhancing denture retention. Two resin(Lucitone $199^{(R)}$(heat cured resin) Vertex $CP^{(R)}$(self cured resin)) and two metal($Biosil^{(R)}$(Co-Cr alloy), $Vitallium^{(R)}$(Co-Cr alloy)) denture base materials were used for making test denture base. Newly developed device was used for measuring denture retention. After the retention was measured. We treated internal surface of test denture base with $50{\mu}m\;Al_2O_3$ powder, under 90psi, for 1 minute. Then the retention was measured again. The result was analyzed with K-S test, one-way ANOVA test and independent t-test to deter mine the significant differences as the 95% level of confidence. The results are as follows : In cases of without internal surface treatment, the retention was increased in order of $Vitallium^{(R)},\;Biosil^{(R)},\;Vertex CP^{(R)}$ and Lucitone $199^{(R)}$. Except between Vertex $CP^{(R)}$ and $Biosil^{(R)}$, retention of the other materials was significantly different (p<0.05). After the treatment of internal surface, the retention was increased in order of $Vitallium^{(R)},\;Biosil^{(R)},\;Lucno\;199^{(R)},\;Vertex\;CP^{(R)}$. Except between Lucitone $199^{(R)}$ and Vertex $CP^{(R)}$, $Vitallium^{(R)}$ and $Biosil^{(R)}$ the retention of remaining groups was significantly different each other (p<0.05). In the matter of each material, after the internal surface treatment the retention was increased with Vertex $CP^{(R)},\;Biosil^{(R)}\;and\;Vitallium^{(R)}$ and the value of differences were statistically significant. When we compare the retention of resin and metal denture base, the retention of both denture bases increased significantly with internal surface treatment, and resin denture base showed better retention. As the results show, selecting denture base material could be an important choice of complete denture treatment. To increase denture retention, internal surface treatment can be considered as a possible method.

  • PDF

A STUDY ON THE POLYMERIZATION STRESS OF COMPOSITE RESINS (복합레진의 중합수축력에 관한 연구)

  • Kim, Boo-Rang;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.331-341
    • /
    • 1992
  • The purpose of this study was to measure the polymerization contraction stress of two types of composite resins; chemical cured type(Cliarfil F II, Kuraray, Japan) and photo-cured type(Photo-Clearfil Bright, Kuraray, Japan). The stresses of composite resin by contraction measured with specially designed measuring device(Fig. 1). The stresses caused by shrinkage during hardening of specimens were measured according to the type of composite resins, thickness of specimen(0.65, 1.30 and 1.95mm), and ratio of catalyst to base in case of only chemical cured composite resin(0.5, 1.0 and 1.5). As the composite resin specimen shrank on hardening, the load cell recorded force vs time automatically on pen-recorder(Toa, Japan) with a cross-head speed 60mm/hr at 0~10 voltages up to 2 hours. The experiments were conducted in a room maintained at $23{\pm}2^{\circ}C$ and relative humidity $50{\pm}10%$. The results were as follows. 1. The contraction stress during hardening was higher in photo cured composite resin than in chemical cured composite resin. 2. The contraction stress during hardening was increased with thickness of composite resin specimen. 3. In chemical cured composite resin, the polymerization contraction stress was decreased with ratio of catalyst and base. 4. The contraction stress during polymerization was higher in early time after insertion of photo cured composite resin and chemical cured composite resin.

  • PDF