• Title/Summary/Keyword: Resin adhesive

Search Result 823, Processing Time 0.026 seconds

Effect of Aceton-Formaldehyde Resin Addition on Bonding Strength of Urea-Formaldehyde Resin Adhesive (요소수지(尿素樹脂)의 접착력(接着力)에 미치는 아세톤수지(樹脂) 첨가(添加)의 영향(影響))

  • Kim, Su Chang;Bae, Young Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.60 no.1
    • /
    • pp.37-44
    • /
    • 1983
  • Thermoplastic aceton-formaldehyde resin adhesive was added as a modifier for urea-formaldehyde resin adhesive and its effects on plywood smear strength and wood failure were investigated. The results are summarized as follows: 1) The plywood shear strength and wood failure showed the highest values at $120^{\circ}C$ of hot plate temperature, but the values decreased according to the rise of addition ratio of aceton resin. 2) The variation of molar ratio of aceton resin had no effect on plywood shear strength and wood failure. 3) The plywood bonded by the addition of aceton resin showed lower values than those of urea resin bonding plywoods in shear strength and wood failure. Therefore, aceton resin was inadequate as a modifier of urea resin adhesive.

  • PDF

Adhesion of 10-MDP containing resin cements to dentin with and without the etch-and-rinse technique

  • Turp, Volkan;Sen, Deniz;Tuncelli, Betul;Ozcan, Mutlu
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.226-233
    • /
    • 2013
  • PURPOSE. This study evaluated the adhesion of 10-MDP containing self-etch and self-adhesive resin cements to dentin with and without the use of etch-and-rinse technique. MATERIALS AND METHODS. Human third molars (N=180) were randomly divided into 6 groups (n=30 per group). Conventional (Panavia F2.0, Kuraray-PAN) and self-adhesive resin cements (Clearfil SA, Kuraray-CSA) were bonded to dentin surfaces either after application of 3-step etch-and-rinse (35% $H_3PO_4$ + ED Primer) or two-step self-etch adhesive resin (Clearfil SE Bond). Specimens were subjected to shear bond strength test using the universal testing machine (0.5 mm/min). The failure types were analyzed using a stereomicroscope and quality of hybrid layer was observed under a scanning electron microscope. The data (MPa) were analyzed using two-way ANOVA and Tukey's tests (${\alpha}$=.05). RESULTS. Overall, PAN adhesive cement showed significantly higher mean bond strength ($12.5{\pm}2.3-14.1{\pm}2.4$ MPa) than CSA cement ($9.3{\pm}1.4-13.9{\pm}1.9$ MPa) (P<.001). Adhesive failures were more frequent in CSA cement groups when used in conjunction with two-step self-adhesive (68%) or no adhesive at all (66%). Hybrid layer quality was inferior in CSA compared to PAN cement in all conditions. CONCLUSION. In clinical situations where bonding to dentin substrate is crucial, both conventional and self-adhesive resin cements based on 10-MDP can benefit from etch-and-rinse technique to achieve better quality of adhesion in the early clinical period.

EFFECT OF DISINFECTION OF CUSTOM TRAY MATERIALS ON ADHESIVE PROPERTIES OF SEVERAL IMPRESSION MATERIAL SYSTEMS (소독제가 개인용 트레이와 실리콘 인상재의 접착력에 미치는 영향에 대한 연구)

  • Kim, Jung-Han;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hic-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.290-298
    • /
    • 1996
  • The effects of impression tray disinfection procedures on the bond strength of impression-material adhesive to two of types resin trays were evaluated with a tensile test. Autopolyme-rizing acrylic resin was formed into 1x1x1 cm cubes. A hook was attached to each cube with autopolymerizing acrylic resin. Perforated trays were fabricated with stops to maintain an even 3 cm of impression material over the resin block. Hook on the opposite side of the perforated tray permitted attachment of the metal plate to a mechanical testing machine. Before adhesive was applied, one third of the resin specimens were immersed in a 5% sodium hypochlorite solution : one third in a 2% glutaradehyde solution, and one third were kept in the "as fabricated" condition. Three products(Perfect ups, Exafine, and Exp-ress) of polyvynil siloxane impression material-adhesive system were evaluated. The resin-impression material-metal plate couples were attached to a mechanical testing machine and tensile forces were applied at a separation rate of 10 centimeters per second. The results were as follows; 1. Both disinfectant and adhesive had effects on bond strength values, but adhesive had more effect than disinfectant(p<0.01). However, there was no interaction between dinin-fectant and adhesive(p>0.01). 2. Mean bond strength values for the Perfect materials were about 85% less than that of the Exafine or the Express materials. However, there was no stastically significant difference between the mean bond strength values of the Exafine materials and the Express materials(p>0.05). 3. The use of disinfectants produced significant reduction in bond strength values(p<0.05). But there was no stastically significant difference between the mean bond strength values of the groups treated with disinfectants(p>0.05).

  • PDF

The effect of dentin desensitizers and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin

  • Acar, Ozlem;Tuncer, Duygu;Yuzugullu, Bulem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.88-95
    • /
    • 2014
  • PURPOSE. The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS. Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA) 2) Aqua-Prep F-(Fluoride), 3) Bisblock-(Oxalate), 4) Cervitec Plus-(Clorhexidine), 5) Smart protect-(Triclosan), 6) Nd:YAG laser, 7) No treatment (control). After applying the selected agent, RelyX U200 self-adhesive resin cement was used to bond composite resin blocks to dentin. All groups were subjected to thermocycling for 1000 cycles between $5-55^{\circ}C$. Each bonded specimen was sectioned to microbars ($6mm{\times}1mm{\times}1mm$) (n=20). Specimens were submitted to microtensile bond strength test at a crosshead speed of 0.5 mm/min. Kolmogorov-Smirnov, Levene's test, Kruskal-Wallis One-way Analysis of Variance, and Conover's nonparametric statistical analysis were used (P<.05). RESULTS. Gluma, Smart Protect and Nd:YAG laser treatments showed comparable microtensile bond strengths compared with the control group (P>.05). The microtensile bond strengths of Aqua-Prep F, and Cervitec Plus were similar to each other but significantly lower than the control group (P<.05). Bisblock showed the lowest microtensile bond strength among all groups (P<.001). Most groups showed adhesive failure. CONCLUSION. Within the limitation of this study, it is not recommended to use Aqua-prep F, Cervitec Plus and Bisblock on dentin when used with a self-adhesive resin cement due to the decrease they cause in bond strength. Beside, pre-treatment of dentin with Gluma, Smart protect, and Nd:YAG laser do not have a negative effect.

Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic

  • Tae-Yub Kwon;Seung-Hee Han;Du-Hyeong Lee;Jin-Woo Park;Young Kyung Kim
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia. MATERIALS AND METHODS. Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test. RESULTS. The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (P < .001), the PF/CON obtained a higher SBS value than the DL/CON (P < .001) and no decrease even after thermocycling (P = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (P < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (P = .002), showing no significant decrease after thermocycling (P > .05). The initial SBS of the PF/PBU was similar to the PF/CON (P = .999), but the value decreased after thermocycling (P < .001). CONCLUSION. The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.

Influence of 10-MDP concentration on the adhesion and physical properties of self-adhesive resin cements

  • Shibuya, Kazuhiko;Ohara, Naoko;Ono, Serina;Matsuzaki, Kumiko;Yoshiyama, Masahiro
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.45.1-45.10
    • /
    • 2019
  • Objectives: Self-adhesive resin cements contain functional monomers that enable them to adhere to the tooth structure without a separate adhesive or etchant. One of the most stable functional monomers used for chemical bonding to calcium in hydroxyapatite is 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP). The aim of this study was to evaluate the influence of the10-MDP concentration on the bond strength and physical properties of self-adhesive resin cements. Materials and Methods: We used experimental resin cements containing 3 different concentrations of 10-MDP: 3.3 wt% (RC1), 6.6 wt% (RC2), or 9.9 wt% (RC3). The micro-tensile bond strength of each resin cement to dentin and a hybrid resin block (Estenia C&B, Kuraray Noritake Dental) was measured, and the fractured surface morphology was analyzed. Further, the flexural strength of the resin cements was measured using the three-point bending test. The water sorption and solubility of the cements following 30 days of immersion in water were measured. Results: The bond strength of RC2 was significantly higher than that of RC1. There was no significant difference between the bond strength of RC2 and that of RC3. The water sorption of RC3 was higher than that of any other cement. There were no significant differences in the three-point bending strength or water solubility among all three types of cements. Conclusions: Within the limitations of this study, it is suggested that 6.6 wt% 10-MDP showed superior properties than 3.3 wt% or 9.9 wt% 10-MDP in self-adhesive resin cement.

The Study of Polar Effects of Aluminium Sulfate on the Reduction of Phenolic Resin Spreading Content for the Manufacture of Plywood (황산(黃酸)알루미늄의 극성효과(極性效果)로 인(因)한 합판용(合板用) 페놀 수지(樹脂) 도포량(塗布量)의 감소(減少)에 관(關)한 연구(硏究))

  • Lee, Joung-Sin;Lee, Hwa-Hyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.29-35
    • /
    • 1986
  • This study was carried out to examine the effect of aluminium sulfate addition to the alkali-acid catalyst phenolic resin for the manufacture of the kapur (Dryobalanops spp.) plywood on the reduction of phenolic resin spreading. On the manufacture of plywood, Adhesive Contents such as 50g/$m^2$, 75g/$m^2$ and 150g/$m^2$ were treated. The spreading adhesive content of 50g/$m^2$ and 75g/$m^2$ had been controlled to about 150g/$m^2$ added with the water in order to get sufficient spreading and controlled to pH 4.5 with aluminium sulfate [$Al_2(SO_4)_3$]. The results are summarized as follows: 1. Specific gravities of air dried plywood manufactured from each adhesive ranged from 0.77 to 0.86 and their moisture contents met the KS requirements. 2. In dry and wet shear strengths, 150 $P_{Al{\cdot}Ac}$ adhesive showed the highest and 75 $P_{Al{\cdot}Ac{\cdot}Am}$ adhesive indicated higher value than 150 $P_{Al{\cdot}Ac}$ adhesive. 3. In case of glue shear strength after boiling test, 150 $P_{Al{\cdot}Ac}$ adhesive was the best and adding of aluminium sulfate was not effective on reinforcement of boiling water resistance of phenolic resin, but met KS requirements. 4. 75 $P_{Al{\cdot}Ac{\cdot}Am}$ adhesive showed the good shear strength and met KS requirements. Therefore, adding of aluminium sulfate was very efficient for economical plywood manufacture.

  • PDF

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

EFFECT OF FILM THICKNESS OF RESIN CEMENT ON BONDING EFFICIENCY IN INDIRECT COMPOSITE RESTORATION (레진 시멘트의 film thickness가 간접 복합 레진 수복물의 접착 효율에 미치는 영향에 관한 연구)

  • Lee, Sang-Hyuck;Choi, Gi-Woon;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.69-79
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of film thickness of various resin cements on bonding efficiency in indirect composite restoration by measurement of microtensile bond strength, polymerization shrinkage, flexural strength and modulus, fractographic FE-SEM analysis. Experimental groups were divided according to film thickness (< $50\;{\mu}m$-control, $50\;{\mu}m$-T50, $100\;{\mu}m$-T100, $150\;{\mu}m$-T150) using composite- based resin cements (Variolink II, Duo-Link) and adhesive-based resin cements (Panavia F, Rely X Unicem). The data was analyzed using ANOVA and Duncan's multiple comparison test (p < 0.05). The results were as follows ; 1. Variolink II showed higher microtensile bond strength than that of adhesive-based resin cements in all film thickness (p < 0.05) but Duo-Link did not show significant difference except control group (p > 0.05). 2. Microtensile bond strength of composite-based resin cements were decreased significantly according to increasing film thickness (p < 0.05) but adhesive-based resin cements did not show significant difference among film thickness (p > 0.05). 3. Panavia F showed significantly lower polymerization shrinkage than other resin cements (p < 0.05). 4. Composite-based resin cements showed significantly higher flexural strength and modulus than adhesive-based resin cements (p < 0.05). 5. FE-SEM examination showed uniform adhesive layer and well developed resin tags in composite-based resin cements but unclear adhesive layer and poorly developed resin tags in adhesive-based resin cements. In debonded surface examination, composite-based resin cements showed mixed failures but adhesive-based resin cements showed adhesive failures.