• 제목/요약/키워드: Resin adhesive

검색결과 823건 처리시간 0.031초

요소수지(尿素樹脂)의 접착력(接着力)에 미치는 아세톤수지(樹脂) 첨가(添加)의 영향(影響) (Effect of Aceton-Formaldehyde Resin Addition on Bonding Strength of Urea-Formaldehyde Resin Adhesive)

  • 김수창;배영수
    • 한국산림과학회지
    • /
    • 제60권1호
    • /
    • pp.37-44
    • /
    • 1983
  • 요소수지(尿素樹脂)의 변성제(變性劑)로서 열가망성(熱可望性)의 아세톤수지(樹脂)를 첨가(添加)하고 합판(合板)의 접착력(接着力) 및 목파율(木破率)에 미치는 영향(影響)을 조사(調査)하였다. 결론(結論)을 요약(要約)하면 다음과 같다. 1) 합판(合板)의 접착력(接着力)과 목파율(木破率)은 열판온도(熱板溫度) $120^{\circ}C$에서 제조한 것이 가장 좋은 값을 보였으나 아세톤수지(樹脂)의 혼합비율(混合比率)이 증가(增加)함에 따라서 그 값은 점차 감소(減少)되었다. 2) 아세톤수지(樹脂)의 몰비율(比率)은 합판(合板)의 접착력(接着力) 및 목파율(木破率)에 영향(影響)을 미치지 않았다. 3) 아세톤수지(樹脂)를 혼용(混用)한 합판(合板)은 요소수지(尿素樹脂)만으로 접착(接着)된 합판(合板)의 접착력(接着力) 및 목파율(木破率)을 능가하지 못했다. 따라서 아세톤수지(樹脂)는 요소수지(尿素樹脂)의 변성제(變性劑)는 부적당(不適當)하였다.

  • PDF

Adhesion of 10-MDP containing resin cements to dentin with and without the etch-and-rinse technique

  • Turp, Volkan;Sen, Deniz;Tuncelli, Betul;Ozcan, Mutlu
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.226-233
    • /
    • 2013
  • PURPOSE. This study evaluated the adhesion of 10-MDP containing self-etch and self-adhesive resin cements to dentin with and without the use of etch-and-rinse technique. MATERIALS AND METHODS. Human third molars (N=180) were randomly divided into 6 groups (n=30 per group). Conventional (Panavia F2.0, Kuraray-PAN) and self-adhesive resin cements (Clearfil SA, Kuraray-CSA) were bonded to dentin surfaces either after application of 3-step etch-and-rinse (35% $H_3PO_4$ + ED Primer) or two-step self-etch adhesive resin (Clearfil SE Bond). Specimens were subjected to shear bond strength test using the universal testing machine (0.5 mm/min). The failure types were analyzed using a stereomicroscope and quality of hybrid layer was observed under a scanning electron microscope. The data (MPa) were analyzed using two-way ANOVA and Tukey's tests (${\alpha}$=.05). RESULTS. Overall, PAN adhesive cement showed significantly higher mean bond strength ($12.5{\pm}2.3-14.1{\pm}2.4$ MPa) than CSA cement ($9.3{\pm}1.4-13.9{\pm}1.9$ MPa) (P<.001). Adhesive failures were more frequent in CSA cement groups when used in conjunction with two-step self-adhesive (68%) or no adhesive at all (66%). Hybrid layer quality was inferior in CSA compared to PAN cement in all conditions. CONCLUSION. In clinical situations where bonding to dentin substrate is crucial, both conventional and self-adhesive resin cements based on 10-MDP can benefit from etch-and-rinse technique to achieve better quality of adhesion in the early clinical period.

소독제가 개인용 트레이와 실리콘 인상재의 접착력에 미치는 영향에 대한 연구 (EFFECT OF DISINFECTION OF CUSTOM TRAY MATERIALS ON ADHESIVE PROPERTIES OF SEVERAL IMPRESSION MATERIAL SYSTEMS)

  • 김정한;정창모;전영찬;황의성
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.290-298
    • /
    • 1996
  • The effects of impression tray disinfection procedures on the bond strength of impression-material adhesive to two of types resin trays were evaluated with a tensile test. Autopolyme-rizing acrylic resin was formed into 1x1x1 cm cubes. A hook was attached to each cube with autopolymerizing acrylic resin. Perforated trays were fabricated with stops to maintain an even 3 cm of impression material over the resin block. Hook on the opposite side of the perforated tray permitted attachment of the metal plate to a mechanical testing machine. Before adhesive was applied, one third of the resin specimens were immersed in a 5% sodium hypochlorite solution : one third in a 2% glutaradehyde solution, and one third were kept in the "as fabricated" condition. Three products(Perfect ups, Exafine, and Exp-ress) of polyvynil siloxane impression material-adhesive system were evaluated. The resin-impression material-metal plate couples were attached to a mechanical testing machine and tensile forces were applied at a separation rate of 10 centimeters per second. The results were as follows; 1. Both disinfectant and adhesive had effects on bond strength values, but adhesive had more effect than disinfectant(p<0.01). However, there was no interaction between dinin-fectant and adhesive(p>0.01). 2. Mean bond strength values for the Perfect materials were about 85% less than that of the Exafine or the Express materials. However, there was no stastically significant difference between the mean bond strength values of the Exafine materials and the Express materials(p>0.05). 3. The use of disinfectants produced significant reduction in bond strength values(p<0.05). But there was no stastically significant difference between the mean bond strength values of the groups treated with disinfectants(p>0.05).

  • PDF

The effect of dentin desensitizers and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin

  • Acar, Ozlem;Tuncer, Duygu;Yuzugullu, Bulem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.88-95
    • /
    • 2014
  • PURPOSE. The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS. Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA) 2) Aqua-Prep F-(Fluoride), 3) Bisblock-(Oxalate), 4) Cervitec Plus-(Clorhexidine), 5) Smart protect-(Triclosan), 6) Nd:YAG laser, 7) No treatment (control). After applying the selected agent, RelyX U200 self-adhesive resin cement was used to bond composite resin blocks to dentin. All groups were subjected to thermocycling for 1000 cycles between $5-55^{\circ}C$. Each bonded specimen was sectioned to microbars ($6mm{\times}1mm{\times}1mm$) (n=20). Specimens were submitted to microtensile bond strength test at a crosshead speed of 0.5 mm/min. Kolmogorov-Smirnov, Levene's test, Kruskal-Wallis One-way Analysis of Variance, and Conover's nonparametric statistical analysis were used (P<.05). RESULTS. Gluma, Smart Protect and Nd:YAG laser treatments showed comparable microtensile bond strengths compared with the control group (P>.05). The microtensile bond strengths of Aqua-Prep F, and Cervitec Plus were similar to each other but significantly lower than the control group (P<.05). Bisblock showed the lowest microtensile bond strength among all groups (P<.001). Most groups showed adhesive failure. CONCLUSION. Within the limitation of this study, it is not recommended to use Aqua-prep F, Cervitec Plus and Bisblock on dentin when used with a self-adhesive resin cement due to the decrease they cause in bond strength. Beside, pre-treatment of dentin with Gluma, Smart protect, and Nd:YAG laser do not have a negative effect.

Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic

  • Tae-Yub Kwon;Seung-Hee Han;Du-Hyeong Lee;Jin-Woo Park;Young Kyung Kim
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권2호
    • /
    • pp.105-114
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia. MATERIALS AND METHODS. Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test. RESULTS. The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (P < .001), the PF/CON obtained a higher SBS value than the DL/CON (P < .001) and no decrease even after thermocycling (P = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (P < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (P = .002), showing no significant decrease after thermocycling (P > .05). The initial SBS of the PF/PBU was similar to the PF/CON (P = .999), but the value decreased after thermocycling (P < .001). CONCLUSION. The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.

Influence of 10-MDP concentration on the adhesion and physical properties of self-adhesive resin cements

  • Shibuya, Kazuhiko;Ohara, Naoko;Ono, Serina;Matsuzaki, Kumiko;Yoshiyama, Masahiro
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.45.1-45.10
    • /
    • 2019
  • Objectives: Self-adhesive resin cements contain functional monomers that enable them to adhere to the tooth structure without a separate adhesive or etchant. One of the most stable functional monomers used for chemical bonding to calcium in hydroxyapatite is 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP). The aim of this study was to evaluate the influence of the10-MDP concentration on the bond strength and physical properties of self-adhesive resin cements. Materials and Methods: We used experimental resin cements containing 3 different concentrations of 10-MDP: 3.3 wt% (RC1), 6.6 wt% (RC2), or 9.9 wt% (RC3). The micro-tensile bond strength of each resin cement to dentin and a hybrid resin block (Estenia C&B, Kuraray Noritake Dental) was measured, and the fractured surface morphology was analyzed. Further, the flexural strength of the resin cements was measured using the three-point bending test. The water sorption and solubility of the cements following 30 days of immersion in water were measured. Results: The bond strength of RC2 was significantly higher than that of RC1. There was no significant difference between the bond strength of RC2 and that of RC3. The water sorption of RC3 was higher than that of any other cement. There were no significant differences in the three-point bending strength or water solubility among all three types of cements. Conclusions: Within the limitations of this study, it is suggested that 6.6 wt% 10-MDP showed superior properties than 3.3 wt% or 9.9 wt% 10-MDP in self-adhesive resin cement.

황산(黃酸)알루미늄의 극성효과(極性效果)로 인(因)한 합판용(合板用) 페놀 수지(樹脂) 도포량(塗布量)의 감소(減少)에 관(關)한 연구(硏究) (The Study of Polar Effects of Aluminium Sulfate on the Reduction of Phenolic Resin Spreading Content for the Manufacture of Plywood)

  • 이종신;이화형
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권2호
    • /
    • pp.29-35
    • /
    • 1986
  • This study was carried out to examine the effect of aluminium sulfate addition to the alkali-acid catalyst phenolic resin for the manufacture of the kapur (Dryobalanops spp.) plywood on the reduction of phenolic resin spreading. On the manufacture of plywood, Adhesive Contents such as 50g/$m^2$, 75g/$m^2$ and 150g/$m^2$ were treated. The spreading adhesive content of 50g/$m^2$ and 75g/$m^2$ had been controlled to about 150g/$m^2$ added with the water in order to get sufficient spreading and controlled to pH 4.5 with aluminium sulfate [$Al_2(SO_4)_3$]. The results are summarized as follows: 1. Specific gravities of air dried plywood manufactured from each adhesive ranged from 0.77 to 0.86 and their moisture contents met the KS requirements. 2. In dry and wet shear strengths, 150 $P_{Al{\cdot}Ac}$ adhesive showed the highest and 75 $P_{Al{\cdot}Ac{\cdot}Am}$ adhesive indicated higher value than 150 $P_{Al{\cdot}Ac}$ adhesive. 3. In case of glue shear strength after boiling test, 150 $P_{Al{\cdot}Ac}$ adhesive was the best and adding of aluminium sulfate was not effective on reinforcement of boiling water resistance of phenolic resin, but met KS requirements. 4. 75 $P_{Al{\cdot}Ac{\cdot}Am}$ adhesive showed the good shear strength and met KS requirements. Therefore, adding of aluminium sulfate was very efficient for economical plywood manufacture.

  • PDF

상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구 (The study of shear bond strength of a self-adhesive resin luting cement to dentin)

  • 인희선;박종일;최종인;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.535-543
    • /
    • 2008
  • 최근의 레진 접착시스템은 단계를 줄이고 적용과정을 간편화시키는데 주력하고 있으며, 치면에 bonding 및 conditioning 과정 없이 바로 적용 가능한, one-step의 새로운 자가 접착 레진시멘트 (self-adhesive resin luting cement)들이 소개되어 임상에 사용되고 있다. 이에 본 연구의 목적은 자가 접착 레진시멘트와 기존의 레진시멘트의 상아질에 대한 전단 결합 강도를 비교해보고, 자가 접착 레진시멘트 적용시 치면의 식각 처리 여부가 전단 결합 강도에 미치는 영향에 관하여 알아보고자 하는 것이다. 본 연구를 위해 최근 6개월 내 발치된 비교적 건전한 성인의 대구치 45개를 아크릴릭 레진으로 매몰한 다음, 800 grit SiC연마지로 연마를 시행하여 상아질을 노출시켰다. 15개의 치아를 한 군으로 하여, 세 가지 실험군으로 분류하였다. Group 1) 치면에 아무런 전처리 없이 RelyX Unicem 접착. Group 2) 치면에 인산 산부식 처리 후, RelyX Unicem 접착, Group 3) 치면에 Syntac primet + Syntac adhesive + Heliobond 처리 후 Variolink II 접착. 전처리가 완료된 치아 시편 위에 플라스틱 튜브 (직경 3 mm, 높이 3 mm)를 고정한 다음, 제조사의 지시에 따라 각 레진 시멘트를 혼합하여 링 안을 채우고, 광중합을 시행하였다. 접착이 완료된 시편은 $37^{\circ}C$ 항온수조 (증류수)에서 24시간 동안 보관 후, 만능 시험기를 이용하여 1mm/min의 cross head speed로 결합강도를 측정하였으며, 확대경 하에서 파절 양상을 분류 관찰하고, 주사전자현미경을 이용하여 미세구조를 관찰하였다. 측정결과는 SPSS WIN 12.0 프로그램을 사용하여 분석하였으며 다음과 같은 결과를 얻었다. 1. RelyX Unicem의 상아질에 대한 전단결합강도는 Variolink II와 유의한 차이를 보이지 않았다. 2. 상아질에 대한 인산 산부식 처리는 RelyX Unicem과의 전단결합강도를 낮게 하였다. 3. RelyX Unicem과 Variolink II에서는 혼합 파절의 비율이 컸으며, 전단결합강도가 낮았던 인산 산부식 처리 후 RelyX Unicem을 접착한 경우에서는 전체 시편에서 접착성 파절이 관찰되었다. 결론으로 말하면, 자가 접착 레진시멘트와 기존의 레진시멘트의 상아질에 대한 전단결합강도는 유의한 차이를 보이지 않으며, 인산 산부식 처리는 상아질에 대한 자가 접착 레진시멘트의 전단결합강도를 감소시킨다.

레진 시멘트의 film thickness가 간접 복합 레진 수복물의 접착 효율에 미치는 영향에 관한 연구 (EFFECT OF FILM THICKNESS OF RESIN CEMENT ON BONDING EFFICIENCY IN INDIRECT COMPOSITE RESTORATION)

  • 이상혁;최기운;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.69-79
    • /
    • 2010
  • 본 연구는 여러 레진 시멘트의 film thickness에 따른 상아질과 간접 레진 수복물 간의 미세인장 결합 강도를 측정하고, 각 레진 시멘트의 중합 수축 및 굴곡 강도, 탄성 계수를 비교 분석하며, 접착 계면 및 파단면의 주사전자 현미경 관찰을 통하여 레진 시멘트의 film thickness가 레진 간접 수복물의 접착 효율에 미치는 영향을 평가하고자 시행하였다. 복합 레진형 레진 시멘트인 Variolink II와 Duo-Link, 접착형 레진 시멘트인 Panavia F와 Rely X Unicem의 4가지 레진 시멘트를 사용하였고, 각각의 시멘트를 film thickness에 따라 < $50\;{\mu}m$ (control)의 대조군과 $50\;{\mu}m$ (T50), $100\;{\mu}m$ (T100), $150\;{\mu}m$ (T150)의 실험군으로 나누어 총 16개의 군으로 분류하였다. 데이터는 ANOVA와 Duncan's multiple comparison test (p < 0.05)를 이용하여 통계 분석하였으며 다음과 같은 결론을 얻었다; 1. Variolink Ⅱ는 모든 film thickness에서 접착형 레진 시멘트보다 높은 결합 강도를 나타냈지만(p < 0.05), Duo-Link는 대조군을 제외하고는 통계학적 유의차가 없었다(p > 0.05). 2. Film thickness가 증가할수록 복합 레진형 레진 시멘트의 결합 강도는 유의성 있게 감소(p < 0.05)하는 경향을 보인 반면, 접착형 레진 시멘트는 통계학적 유의차가 없었다(p > 0.05). 3. Panavia F는 통계학적으로 유의성 있게 낮은 중합 수축량을 나타냈다(p <0.05). 4. 굴곡 강도와 탄성 계수는 복합 레진형 레진 시멘트가 접착형 레진 시멘트보다 유의성 있게 높게 나타났다(p < 0.05). 5. FE-SEM 관찰 결과 결합 강도가 높은 복합 레진형 레진 시멘트는 균일한 접착층과 잘 발달된 resin tag 소견을 보였으나, 접착형 레진 시멘트는 불분명한 접착층과 resin tag 소견을 나타냈다. 파단면 관찰에서 복합 레진형 레진 시멘트는 혼합형 파괴 양상을 나타냈으나 접착형 레진 시멘트는 접착성 파괴 양상을 나타냈다.