• Title/Summary/Keyword: Residual Power

Search Result 727, Processing Time 0.029 seconds

The Effects of an Abnormal Adjusting Intake and Exhaust Valves on the Combustion Characteristics of SI Engine (흡.배기 밸브의 밀착이상이 엔진연소특성에 미치는 영향)

  • Park Kyoung-Suk;Son Sung-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.123-129
    • /
    • 2005
  • The unbalance of the power output, noise, and vibration is happened by the disproportionate pressure variation in the cylinder. For this reason, decrease of the pressure in the cylinder and increase of the residual gas effect on the engine performance. If the abnormal combustion is continued, the crack would be occurred in the engine block. And it could be broken down. For the normal combustion of the SI engine, it is important to supply the balanced mixture by each operating condition. In this study, it was tested the combustion characteristics in the cylinder according to the abnormal adjusting of intake & exhaust valve. This test is willing to set a basic data's analysis fur developing an automotive diagnosis system by analyzing the pressure in the cylinder, the output signal of MAP sensor, the exhaust gas, etc.

Comparison of Structural Change Tests in Linear Regression Models

  • Kim, Jae-Hee
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1197-1211
    • /
    • 2011
  • The actual power performance of historical structural change tests are compared under various alternatives. The tests of interest are F, CUSUM, MOSUM, Moving Estimates and empirical distribution function tests with both recursive and ordinary least-squares residuals. Our comparison of the structural tests involves limiting distributions under the hypothesis, the ability to detect the alternative hypotheses under one or double structural change, and smooth change in parameters. Even though no version is uniformly superior to the other, the knowledge about the properties of those tests and connections between these tests can be used in practical structural change tests and in further research on other change tests.

The Controllable Current-Source Active Power Filter (가변 전류형 능동 전력 필터)

  • Kim, Ho-Jin;Cho, Han-Duk;Kim, Hong-Seong;Choe, Gyu-Ha;Kim, Han-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1077-1080
    • /
    • 1992
  • In this paper suggested methods for current control in active filter are using the triangular carriers which were composed of independently generated threefold carriers and controllable current source which compensates the harmonics generated independently from the types of the load with instantaneous amplitude adjusting from the maximum magnitude of the compensating currents. And the 2-nd order high pass passive filter connected to the source finally supplies pure sinusoidal waves by suppressing the residual harmonics which cannot removed by the active filter. As the typical load which generates the harmonics, a rectifier was set and the system was also designed by simulations and implementations.

  • PDF

A Study on Multiple Bad Data Detection using Binary PSO (이진 PSO를 이용한 Multiple Bad Data 검출에 관한 연구)

  • Jeong, Hee-Myung;Park, June-Ho;Lee, Hwa-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.270_271
    • /
    • 2009
  • The identification of multiple bad data, especially when mutually interacting, may be difficult to handle, since the well known procedures based on the normalized or weighted residuals may become faulty. In such a case, successive elimination of the measurement with the largest normalized residual may result in the suppression of correct measurements instead of the bad data. Then the problem of identifying bad data is considered as a combinatorial decision procedure. In this paper, binary PSO is used for the identification of multiple bad data in the power system state estimation. The proposed binary PSO based procedures behave satisfactorily in the identifying multiple bad data. The test is carried out with reference to the IEEE-14 bus system.

  • PDF

Alloy 600 Components Inspection Prioritization Using the Normalized PWSCC Susceptibility Index (정규화된 PWSCC 민감도 지수를 이용한 Alloy 600 기기 검사 우선순위 선정)

  • Kim, Tae Ryong;Kim, Hyung Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.17-22
    • /
    • 2016
  • Alloy 600 widely used in nuclear power plant is susceptible to primary water stress corrosion cracking (PWSCC). It is important to prioritize the inspection of Alloy 600 components using PWSCC susceptibility index. Plant-specific model for the susceptibility index was reviewed. The normalized PWSCC susceptibility index to a reference value is suggested and applied. The result was found to be reasonable.

Evaluation of the Impacts of SPD Connecting Lead Lengths and SPD Protection Distance to the Apparatus in Apartments (공동주택에서 SPD의 리드선 길이 및 보호거리에 대한 영향 평가)

  • Lee, Ki-Hong;Kang, Moo-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.94-101
    • /
    • 2011
  • The proper installation of SPD and the evaluation of the SPD protection distance are basic steps for the effective protection measures of apparatus against surges within a structure. A novel method for installing SPD on the conventional distribution board without any modification was proposed and it's effectiveness was evaluated by experiments. Also, the transient overvoltage occurred across the power line from the SPD to the load was simulated with EMTP software to see how different the protection distances affecting the magnitude of the transient overvoltage. As evaluated, the effective protection method of apparatus against surges, coordinated SPD protection system is suggested as a proper measure to protect within the apartment.

Contruction and Performance Evaluation of the Surge Arrester for Transmission Class (송전급 피뢰기의 구조와 성능평가)

  • Kim, S.S.;Choi, I.S.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.890-893
    • /
    • 2002
  • Since 1970s, varistors using metal-oxide resistors have been applied to Gapless surge arresters for power system. In the paper, the structure of metal-oxide surge arresters without gaps for 362kV GIS which is developed the first in korea has been introduced. And the main evaluation items for the metal-oxide resistors which are reference voltage test, residual voltage test, long duration current impulse withstand test and operating duty test is tested and evaluated.

  • PDF

Model development for chlorine generation using electrolysis (전기분해에 의한 잔류염소 생성 예측 모델 개발)

  • Sohn, Jinsik;Lee, Sunjae;Shin, Chorong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.331-337
    • /
    • 2009
  • Electrolysis produces hypochlorous acid by using a small quantity of NaCl as electrolyte. This process maximizes the stabilization of drinking water through the control of chlorine residual concentration. This study investigated free chlorine generation by an electrolytic method using $Ti/IrO_2$ and stainless steel. The generation of free chlorine was increased with increasing hydraulic retention time, voltage, chlorine ion concentration and the number of electrodes. However, the change of pH did not affect the generation of free chlorine. There was no significant difference on the behavior of chlorine concentration between electrolytic method and NaOCl injection. In this study, the concentration of free chlorine predicted model based on power functional model was developed various under conditions. Electrolysis free chlorine generation model can be effective tool in the estimation of free chlorine generation.

Deposition of $SiC_xN_y$ Thin Film as a Membrane Application

  • Huh, Sung-Min;Park, Chang-Mo;Jinho Ahn
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • $SiC_{x}N$_{y}$ film is deposited by electron cyclotron resonance plasma chemical vapor deposition system using $SiH_4$(5% in Ar), $CH_4$ and $N_2$. Ternary phase $SiC_{x}N$_{y}$ thin film deposited at the microwave power of 600 W and substrate temperature of 700 contains considerable amount of strong C-N bonds. Change in $CH_4$flow rate can effectively control the residual film stress, and typical surface roughness of 34.6 (rms) was obtained. Extreme]y high hardness (3952 Hv) and optical transmittance (95% at 633 nm) was achieved, which is suitable for a LIGA mask membrane application.

  • PDF

A Modeling of Flame Initiation and Its Development in SI Engines (SI 기관에서 초기 화염의 생성 및 성장에 대한 모델링)

  • Song, Jeonghoon;Sunwoo, Myoungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.288-298
    • /
    • 1999
  • In spark ignited engines, the electrical spark not only sets the time for the onset of combustion but also is able to greatly influence the character of the initial flame growth and the subsequent combustion, and thereby can influence engine performance. The relative importance of the ignition energy is particularly high under lean or high residual gas or exhaust gas recirculation (EGR). In this study, a modeling of flame Initiation and its development is proposed. Submodels consist in representing of cylinder pressure and temperature, heat transfer to cylinder wall, and flame kernel heat transfer to ambient air and to spark plug electrodes. The breakdown process and the subsequent electrical power input initially control the kernel growth while intermediate growth is mainly dominated by diffusion or conduction. Then, the flame propagates by the chemical energy, and laminar and turbulent flame velocity.