• Title/Summary/Keyword: Residual Application Rate

Search Result 138, Processing Time 0.02 seconds

The Seasonal Variation of the Heat Budget in Deukryang Bay (득량만의 열수지 계절 변동)

  • 주용환;조규대
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.67-73
    • /
    • 1998
  • Surface heat budget of the Deukryang Bay from July 1, 1992 to September 12, 1993 is analyzed by us- ing the meteorological data (by Changhung Observatory and Mokpo Meteorological Station) and oceanogaphical data (by Research Center for Ocean Industrial Development. Pukyong National University). Each flux element at the sea surface which has annual variation Is derived with application of an aerodynamical bulk method and empirical formulae. The solar radiation Is the maximum In spring and sensible heat are the maximum in autumn and water. and minimum in summer The heat .storage rate is calclilated by using the rate of water temperature variation according to the depth. The oceanic transport heat is estimated as a residual. The net heat flux, the heat storage rate are positive In spring and summer, while they are negative in autumn and winter. The oceanic transport heat Is convergence In winter and divergence In the rest of seasons.

  • PDF

Performance Analysis of Coding According to the Interpolation filter in Inter layer Intra Prediction of H.264/SVC (H.264/SVC의 계층간 화면내 예측에서 보간법에 따른 부호화 성능 분석)

  • Gil, Dae-Nam;Cheong, Cha-Keon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.225-227
    • /
    • 2009
  • International standard specification, H.264/SVC improved from H.264/AVC, is set up so as to promote free use of huge multimedia data in various channel environments.;H.264/AVC is a international standard speicification for video compression, adopted and commercialized as standard for DMB broadcasting by JVT of ISO/IEC MPEG and ITU-T VCEG. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding. Among prediction technologies, 'inter-layer intra prediction' is to use co-located block of up sampled sublevels as a prediction signal. At this time, application of interpolation is one of the most important factors to determine encoding efficiency. SVC's currently using poly-phase FIR filter of 4-tap and 2-tap respectively to luma components. This paper is written for the purpose of analyzing encoding performance according to the interpolation. For this purpose, we applied poly-phase FIR filter of '2-tap', '4-tap' and '6-tap' respectively to luma components and then measured bit-rate, PNSR and running time of interpolation filter. We're expecting that the analysis results of this paper will be utilized for effective application of interpolation filter. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding.

  • PDF

UTILIZATION AND EVALUATION Of AVAILABLE PHOSPHORUS IN SOILS FOR FLUE-CURD TOBACCO (NICOTIANA TABACUM L.) II. FIELD EXPERIMENT (황색종 담배 (Nicotiana tabacum L.)의 토양중 유효인산의 이용과 그 평가 방법)

  • Park, Su-Jun;Choi, Jyung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.6 no.2
    • /
    • pp.155-168
    • /
    • 1984
  • Field test were conducted to select the best method for soil phosphorus test and to obtain the critical levels of each method for P fertilizer recommendations based on tobacco production. Truog method was recognized to be the mort suitable one for soil P test. N. Carolina, Bray No.1 and Olsen methods were followed in order. Bray No. 2 and Lancaster methods showed the least satisfaction. The critical levels of available P by lancaster, Bray No. 1, N. Carolina,01sen, and Truog methods were 55ppm, 32ppm, 21ppm, 19ppm, and 22ppm, respectively. Below the critical level a large yield response can be expected with 10kg $P_2O_5$/10a, above critical level little or no response is expected. In soils the more the initial available p, the more available P was carried over, while the more the total amount of silt and clay, the less the residual P was found. The increase in residual P by 10kg of $P_2O_5$ was greater than that of 5kg/10a. The chemical composition and the price of the cured leaf were not affected by the $P_2O_5$ application, indicating that the increase in the rate of $P_2O_5$ application would not exert on the quality of tobacco.

  • PDF

Basic Investigation for the Development of Cleaning Technology with Ejector (이젝터를 이용한 세정기술 개발의 기초연구)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.29-36
    • /
    • 2017
  • The paper presents a basic investigation for the development of cleaning technology employing an annular nozzle ejector for application to cleaning water supply and air bubble generation. The quantitative flow characteristics of the primary and suction flows, the qualitative visualization behavior of the mixed jet, and the percentage concentration of pesticide residual at different values of the ejector screw pitch were investigated. It was seen that the primary flow rate increased, while the mass ratio decreased with increase in screw pitch. Further, the mixed jet behaved like a buoyancy jet or horizontal bubbly jet, and the residual concentration of pesticide first decreased and then increased with increase in screw pitch.

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

A Vtub-Shaped Hazard Rate Function with Applications to System Safety

  • Pham, Hoang
    • International Journal of Reliability and Applications
    • /
    • v.3 no.1
    • /
    • pp.1-16
    • /
    • 2002
  • In reliability engineering, the bathtub-shaped hazard rates play an important role in survival analysis and many other applications as well. For the bathtub-shaped, initially the hazard rate decreases from a relatively high value due to manufacturing defects or infant mortality to a relatively stable middle useful life value and then slowly increases with the onset of old age or wear out. In this paper, we present a new two-parameter lifetime distribution function, called the Loglog distribution, with Vtub-shaped hazard rate function. We illustrate the usefulness of the new Vtub-shaped hazard rate function by evaluating the reliability of several helicopter parts based on the data obtained in the maintenance malfunction information reporting system database collected from October 1995 to September 1999. We develop the S-Plus add-in software tool, called Reliability and Safety Assessment (RSA), to calculate reliability measures include mean time to failure, mean residual function, and confidence Intervals of the two helicopter critical parts. We use the mean squared error to compare relative goodness of fit test of the distribution models include normal, lognormal, and Weibull within the two data sets. This research indicates that the result of the new Vtub-shaped hazard rate function is worth the extra function-complexity for a better relative fit. More application in broader validation of this conclusion is needed using other data sets for reliability modeling in a general industrial setting.

  • PDF

A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application (오존의 정수처리 적용을 위한 오존소비인자에 관한 연구)

  • Kang, Tae-Hee;Oh, Byung-Soo;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.663-669
    • /
    • 2005
  • The aim of this study was to investigate the ozone decay pattern for the effective application of ozone in drinking water treatment. In order to measure the ozone decomposition in water, ozone measuring instrument was developed with flow injection analysis (FIA) method. From the result of continuous residual ozone concentration in water, it was confirmed that the ozone decay pattern was divided with instantaneous ozone demand(I.D) and pseudo first-order rate($k_c$) phases, which were influenced by the variation of ozone dose. The empirical model obtained from I.D and $k_c$ values enabled us to predict the residual ozone concentration according to the reaction time, showing the high correlation between model and experimental values. The concentration of OH radical and $R__{ct}$ could be indirectly measured by OH radical probe compound. In both I.D and $k_c$ phases, the production pattern of OH radical could be observed, which was also affected by the variation of ozone dose. Finally, it was confirmed that the ozone consumption rate was varied according to the each drinking water treatment process and seasoning. Therefore, the optimum position and dosage of ozone have to be selected by considering various factors.

Deposition of $SiC_xN_y$ Thin Film as a Membrane Application

  • Huh, Sung-Min;Park, Chang-Mo;Jinho Ahn
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • $SiC_{x}N$_{y}$ film is deposited by electron cyclotron resonance plasma chemical vapor deposition system using $SiH_4$(5% in Ar), $CH_4$ and $N_2$. Ternary phase $SiC_{x}N$_{y}$ thin film deposited at the microwave power of 600 W and substrate temperature of 700 contains considerable amount of strong C-N bonds. Change in $CH_4$flow rate can effectively control the residual film stress, and typical surface roughness of 34.6 (rms) was obtained. Extreme]y high hardness (3952 Hv) and optical transmittance (95% at 633 nm) was achieved, which is suitable for a LIGA mask membrane application.

  • PDF

Biological activities of novel quinolinyloxadiazoles (신규 quinolinyloxadiazole 유도체의 생물활성)

  • Hwang, In-Taek;Choi, Jung-Sub;Hong, Kyung-Sik;Lee, Byung-Hoe;Kim, Jin-Seog;Ryu, Eung-Kul;Cho, Kwang-Yun
    • The Korean Journal of Pesticide Science
    • /
    • v.2 no.3
    • /
    • pp.52-63
    • /
    • 1998
  • A novel quinolineoxadiazoles, substituted the carboxylic acid group with 1,2,4-oxadiazole radicle, of KSC-16960 and related compounds were evaluated to examine the herbicidal activity, crop injury and residual effect of after-vegetable crops compared with those of quinclorac (3,7-dichloro-8-quinolinecarboxylic acid), of which use is now banned because of its residual activity to some succeeding vegetable crops. KSC-16960 showed 2- and 3-leaf stages of barnyardgrasses effectively controlled by more than 95 and 90%, respectively, at a rate of 6.25 g/ha. The dose of KSC-16960 controlled 4- and 5-leaf stages of barnyardgrasses by more than 90% were found to be 50 g and 100 g/ha, respectively. The selectivity of KSC-16960 between direct-seeded rice and barnyardgrass was approximately 2-fold higher than that of quinclorac when they were treated to the soil. The selectivity indices of KSC-16960 and of quinclorac between 1-leaf stage of direct seeded rice and 5-leaf stage of barnyardgrass were 44 and 23, respectively, and those between 1-leaf stage of direct seeded rice and 4-leaf stage of barnyardgrass were almost 2-fold higher. Application of KSC-16960 with bentazone exhibited an additive controlling effect on several weed species, but that of quinclorac exhibited an antagonistic effect. With pyrazosulfuron-ethyl, on the other hand, both application of KSC-16960 and quinclorac showed additive interactions. Under a greenhouse condition, the residual activity of KSC-16960 to succeeding tomato plants was approximately 4-fold lower compared to that of quinclorac. KSC-16960 could be substituted for quinclorac, if it will be made some more improvement for reducing residual activity.

  • PDF

Residual Activity and Effect of Soil-applied Herbicides on Succeeding Crops in Vegetable Fields;4. Residual Amount of Herbicides Nitralin and Napropamide (주요채소용제초제(主要菜蔬用除草劑)의 토양중(土壤中) 잔효와 후작물(後作物)에 미치는 영향(影響);제(第)4보(報) : 제초제(除草劑) Nitralin과 Napropamide의 잔류량조사(殘留量調査))

  • Ryang, H.S.;Moon, Y.H.;Choi, E.S.;Jang, M.S.;Lee, J.H.;Chang, Y.N.
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.2
    • /
    • pp.113-118
    • /
    • 1991
  • The soil residual amount of herbicides nitralin and napropamide was determined in 6 winter crops field using a chemical assay method. Chemical analysis on soil residue revealed that a relatively high amount of nitralin was detected between 150 and 200 days after treament(DAT). However, regardless of soil types the residue at 220 DAT ranged from 0.053 to 0.141ppm and from 0.134 to 0.308ppm, at the rate of 75 and 150 g a.i./10a, respectively. The residue of napropamide applied at the rate of 75 g a.i./l0a ranged from 0.006 to 0.072ppm at 150 DAT, but not detectable at 220 DAT. When application rate increased to 150 g a.i./10a, napropamide residue was between 0.005 and 0.16ppm at 150 DAT and less than 0.004ppm at 200 DAT, and was not detected at 220 DAT, irrespective of soil types. The results of chemical analysis for the two herbicides showed a similar trend to those obtained from the experiments in agar medium and fields.

  • PDF