• Title/Summary/Keyword: Residential water

Search Result 467, Processing Time 0.033 seconds

An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System (가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구)

  • Kong, Hyoung Jin;Kang, Sung Jae;Yun, Kyoung Sik;Lim, Hyo Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

The Study on the Relationship between Land Use and Groundwater Quality in the Rapidly Urbanized Area (도시화가 빠르게 진행된 지역의 토지이용과 지하수 수질과의 관계에 대한 연구)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.97-108
    • /
    • 2002
  • The use of land at the time of investigation of groundwater quality in the rapidly urbanized Bu-chon city is classified into 5 categories based on the change process of land use. The difference in groundwater quality according to the land use and its usage period is tested by non-parametric statistical procedures. The seven constituents of water quality with the highly frequent detection in the area for this study are used for the statistical test. The shallow groundwater quality within the areas of the same land use at the time of investigation varies significantly according to the period of land usage. The concentration of KMnO$_4$consumed and hardness is significantly higher in the old residential area (of more than 20 years old) than in the younger one (of less than 10 years old). The quality of the shallow groundwater is also significantly different among the three categories with the similar period of land usage (of more than 15 years old). The concentration of No$_3$-N, hardness and total solid is significantly higher in the residential area than in the agricultural one (namely, the area used as paddy fields 2 to 5 years ago). The median concentration of these constituents is 2.2 to 3.8 times higher in the residential area than in the agricultural one. The concentration of NO$_3$-N, KMnO$_4$, consumed and Cl is significantly higher in the industrial area than in the agricultural one. The median concentration of these constituents is 5.5 to 18 times higher in the industrial area than in the agricultural one. The concentration of KMnO$_4$consumed is significantly higher in the industrial area than in the residential area. The median concentration of these constituents is 12 times higher in the industrial area than in the residential one. The spatial distribution of shallow groundwater quality in the rapidly urbanized area is closely related to the period of land usage as well as the land use, which is presumed to be attributed to the difference in the concentration and leakage rate of the contaminants leaking from damaged sewer into shallow groundwater.

Determination of the number of storm events monitoring considering urban stormwater runoff characteristics (도시지역의 강우유출수 특성 분석을 통한 적정모니터링 횟수 도출)

  • Choi, Jiyeon;Na, Eunhye;Kim, Hongtae;Kim, Jinsun;Kim, Yongseck;Lee, Jaekwan
    • Journal of Wetlands Research
    • /
    • v.19 no.4
    • /
    • pp.515-522
    • /
    • 2017
  • This study investigated the runoff characteristics containing NPS pollutants in urban areas and estimated the optimal number of storm events to be monitored. 13 residential areas, 8 commercial areas, 9 transportation areas and 11 industrial areas were selected to be monitored located in urban areas. Monitoring was performed from 2008 to 2016 with a total of 632 rainfall events. As a result, it was found that commercial area needs priority NPS management compared to other landuses because the commercial area has high runoff coefficient and NPS pollutant EMC compared with other landuses. The annual monitoring frequency for each landuse was estimated to be 11 to 14 times for industrial area, 12 to 14 times for transportation area, 11 to 13 times for commercial area and 22 to 25 times for residential area. Even with the use of accumulated monitoring data for several years, there is still high probability of uncertainty due to high error in some pollutant items, and it is necessary to establish monitoring know-how and data accumulation to reduce errors by continuous monitoring.

Investigation for analysis methods of water intake and perception on the tap water : the survey result on the seoul tap water, arisu (수돗물 음용 및 인식 분석방법에 대한 고찰 : 서울 수돗물 아리수에 대한 설문 결과)

  • Huh, Jun-Rim;Bhnag, Kon Joon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.461-472
    • /
    • 2014
  • The tap water plays a critical role in our daily life by providing clean water for drinking as well as for residential use. Its importance, however, is often hidden and criticized in mass media because drinking the unprocessed tap water as a primary source of drinking water is very low comparing to other countries. This is because survey tool in Korea is often different from those in other countries so their results on the tap water cannot be directly compared without analysis on survey questionnaire. Therefore, we examplified cases showing the difference of questions of each country and discussed the reason why results of tap water intake should not be compared without analysis on the questions. Also, distrust on Arisu without rational reason is known as the first reason of distrust on the tap water. However, it was not the ultimate reason of distrust on the tap water. To verify, we designed survey questions in a tricky way that the same question was asked twice with different choices in the survey questionnaire. Most of the people who distrust Arisu without rational reason at the first question were selected different choices and significantly reduced in the second question. This proved that the ratio of distrust on the tap water is not actually the right reason and that by providing more choices, people's distrust on the tap water without rational reason can turn into more specific reasons.

Development of an environmentally friendly precipitation treatment system utilizing open space in residential estates (주거단지의 외부공간을 활용한 친환경적 우수처리 시스템 개발)

  • Lee, Eun-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.3
    • /
    • pp.55-65
    • /
    • 2001
  • The hydrological cycle system in the city is generally characterized by quick runoff, bad infiltration, low evaporation rate, and so on. It is caused by sealing greens up with pavements. Also, there are lots of contradictory environmental problems, such as inundation, the lack of underground water and dryness in the city, caused by the urban drainage system which is mostly focused on the quick draining off rainfall. In addition, the technique joining rain and sewage, which has more dangers of inundation, occupies 66% between two Korean drainage systems which consist of joining and dividing system. There has been some need to convert the present drainage system into the environmentally friendly hydrological cycle system. This is a theoretical study to examine some foreign cases and suggested applicable methods in our country, focusing on the environmentalyl friendly system of rainfall drainage. The precipitation treatment system can be made up of some possible phases choosing from premanagement, utilization, infiltration, retention, and inducement phases. Therefore, this study mostly focused on infiltration, retention, and inducement phases. It is necessary to suggest the multifunctional utilization of outdoor spaces, especially applying in new constructing and re-constructing residential estates.

  • PDF

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.

A Study on the Improving Direction of Container Housing through Field Survey - Based on the Analysis of 12 cases in the Urban Area - (국내 컨테이너 하우징의 실태조사를 통한 개선방향연구 - 수도권 지역의 12개 사례를 중심으로 -)

  • Yoo, Hae-Yeon;Park, Yeon-Jeong;Yoon, Jung-Yeon
    • Journal of the Korean housing association
    • /
    • v.23 no.6
    • /
    • pp.21-30
    • /
    • 2012
  • In foreign countries, the use of containers has already been stabilized with their advantages utilized in various forms. Containers are also utilized in Korea as various forms of architecture, but domestic container buildings have poor public consciousness so as to be limitedly utilized as temporary structures based on economic efficiency. Besides, there is the lack of research and development on them. Particularly, despite the advantages of containers as housing facilities, the use of containers as short- or middle-term temporary housing is limited and does not spread. Also, compared to general housing, containers have lower quality of physical environment and even frequently bring about negligent accidents such as fire and electric shock. Thus, this study intends to identify the actual condition of using container houses, the problems in using them, and the direction of improving their residential environment. For this purpose, it analyzes the present condition and characteristics of domestic container housing, and derives conclusions from the focus group interview with 23 residents who have lived in Seoul and Gyeonggi-do for over a year about such survey items as daylighting, ventilation, privacy condition, water service and sewerage, insulation, soundproofing, view, and room scale.

Urinary Arsenic Concentrations among Residents in the Vicinity of a Chungcheongnam-do Province Industrial Complex Area (충청남도 내 산업단지 주변에 거주하는 주민들의 요중 비소 농도)

  • Kim, Hee Chan;Roh, Sangchul
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.3
    • /
    • pp.224-233
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the relationship between residential surroundings, such as a power plant, steel mill and petrochemical facilities, and urinary arsenic concentrations in Chungcheongnam-do Province, Korea. Methods: Stratified by fish consumption and residential district, median and maximum block sampling was applied. A total of 346 spot urine samples were speciated for $As^{5+}$, $As^{3+}$, monomethylarsonic acid(MMA), dimethylarsonic acid (DMA) and arsenobetaine (AsB). Exposure assessment was based on questionnaires including data on sex, age, current tobacco use, fish consumption, type of water consumed, and occupational category. Results: Urinary $As^{5+}+As^{3+}+MMA+DMA$ concentrations of people living in the vicinity of a power plant ($GM=50.39{\mu}g/g$) were 61% higher than those of people living in the inland area according to median block sampling. Urinary $As^{5+}+As^{3+}+MMA+DMA+AsB$ concentrations of people living in the vicinity of industrial complex area were higher than those of people living in the inland area according to block sampling by median and maximum. Conclusion: Urinary arsenic concentrations of people living in vulnerable areas such as around industrial complexes, especially power plants, were higher than those of people living in an inland area.

Field study of 5kW class PEMFC system (5kW급 고분자전해질 연료전지 시스템 실증연구)

  • Lee, SooJae;Choi, Dae Hyun;Jun, HeeKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.